Quadra-Fire CASTINS-CSB, 810-03201, 810-02901, CASTINS-CWL Getting Started, Appliance Location

Page 5

R

Castile Pellet Insert

2 Getting Started

A. Design, Installation & Location Considerations

1.Appliance Location

NOTICE: Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult insurance carrier, local building inspector, fi re offi cials or authorities having jurisdiction over restrictions, installation inspection and permits.

It is a good idea to plan your installation on paper, using exact measurements for clearances and fl oor protection, before actually beginning the installation

Consideration must be given to:

Safety, convenience, traffi c fl ow

Placement of the chimney and chimney connector.

If you are not using an existing chimney, place the appli- ance where there will be a clear passage for a factory- built listed chimney through the ceiling and roof.

Installing an optional outside air kit would affect the loca- tion of the vent termination.

Since pellet exhaust can contain ash, soot or sparks, you must consider the location of:

Windows

Air Intakes

Air Conditioner

Overhang, soffi ts, porch roofs, adjacent walls

Landscaping, vegetation

When locating vent and venting termination, vent above roof line when possible.

Warning! Risk of Fire Damaged parts could impair safe operation. Do NOT install damaged, incomplete or substitute components.

CAUTION! If burning shelled fi eld corn, you must use ap- proved venting specifi cally designed for corn to prevent corro- sion or degradation. Follow the instructions from the venting manufacturer.

NOTICE: Locating the appliance in a location of considerable air movement can cause intermittent smoke spillage from appliance. Do not locate appliance near:

Frequently open doors

Central heat outlets or returns

 

Recommended Location:

Recommended Location:

Above peak

• Above peak

Inside heated space

Location NOT recommended:

Not the highest point of the roof

Wind loading possible

Windward

Marginal Location:

• Below peak

Recommended:

Insulated exterior chase in cooler climates

Marginal Location:

• Wind loading possible

Location NOT recommended:

• Too close to tree

• Below adjacent structure

• Lower roof line

• Avoid outside wall

Leeward

Recommended: Outside Air Intake on windward side

Multi-level Roofs

NOT recommended: Outside Air Intake on leeward side

Figure 5.1

August 20, 2009

250-7251G

Page 5

Image 5
Contents Hot glass will cause burns 810-02901 MBK 810-03201 PMHInsurance carrier, local Castile Pellet InsertBuilding inspector, fi re Inspection and permitsTable of Contents Appliance Certification BTU & Efficiency Specifi cations Listing and Code ApprovalsMobile Home Approved Glass Specifi cationsAppliance Location Getting StartedNegative Pressure Castile Pellet Insert Locating Your Appliance & ChimneyDraft Inspect Appliance & Components and Pre-Use Check List Castile Pellet Insert Fire SafetyTools And Supplies Needed Height Width Panel Size Inch 3Dimensions and ClearancesAppliance Dimensions 0mm Clearance To Exposed Section And Face Trim Castile Pellet Insert Clearance To Combustibles, UL and ULCShown Optional Outside Air Inches MillimetersFloor Protection Castile Pellet Insert Masonry and Zero Clearance FireplacesMinimum Opening for Masonry and Zero Clearance Fireplaces Location Inches MillimetersStarter hole Mark area of floor to cut Altering the Factory-Built Fireplace Castile Pellet Insert Prefabricated Metal ChimneyVenting Termination Requirements 4Vent InformationChimney and Exhaust Connection Example of 3 Elbow-Rear Vent Termination Calculation Pipe Selection ChartCastile Pellet Insert Equivalent Feet of Pipe Full Reline With Outside Air Horizontal Venting SystemsCastile Pellet Insert Full Reline With Outside Air Vertical 6Mobile Home Mobile Home InstallationRear Vent Installation Top Vent Installation7Appliance Set-Up Reversible Top or Rear Flue Adapter Leveling SystemDescription Assembled View20.3 Base Plate Only InstallationCastile Pellet Insert Zero Clearance Trim Support Cont’d 21.3 Panel Set And Cast Trim SetPanel & Trim Set, Econo Four Piece Log Set Installation Castile Pellet Insert Thermostat Installation Fuel Size, Material and Storage 8Operating InstructionsCastile Pellet Insert General Operating Information Fire CharacteristicsBefore Your First Fire Starting Your First FireIginition Cycles Castile Pellet Insert Feed Rate AdjustmentIssues Solutions Frequently Asked QuestionsSymptom TroubleshootingSymptom Possible Cause Corrective Action Page 10Maintaining & Servicing Your Appliance Quick Reference Maintenance ChartTypes of Fuel Frequency Daily Weekly Monthly YearlyCleaning Firepot with Cleaning Rod & Firepot Scraper Remove Cast Sides for Cleaning & MaintenanceNished. See .2 on Ash Removal from FireboxCleaning Heat Exchanger Chambers & Drop Tube Cleaning Ash PanCleaning Beneath Heat Exchanger Cleaning the Exhaust PathCleaning Convection Blower Requires No Lubrication Cleaning the HopperCleaning Exhaust Blower Requires No Lubrication Door Latch Inspection Cleaning the GlassPreparing Firebox for Non-Burn Season Frequency Yearly High Ash Fuel Content MaintenanceDoor Gasket Inspection Igniter Replacement 37.1 Baffl e & Brick Set RemovalRe-installing Baffl e & Brick Set Cont’d Component Function Wiring Harness See .1 below Vacuum SwitchSnap Disc #1 Convection Blower 110F Snap Disc #2 Fuel Delivery Interrupt 250FBlowers & Feed Motor Castile Pellet Insert Component Locations250-7251G August 20 Castile Pellet Insert Exploded DrawingImportant this is Dated Information HOW to Order Castile Pellet Insert Service Parts and AccessoriesDescription Comments Part Number StockedAt Depot TOUCHUP-CSB PEL-DAMP4 Description ACCESSORIESComments Part NumberFasteners Description Comments Part Number Stocked at DepotDate of Service Performed By Description of Service Castile Pellet Insert Service And Maintenance LogCastile Pellet Insert Service And Maintenance Log Cont’d Castile Pellet Insert Warranty Policy Castile Pellet Insert Contact Information

CASTINS-CSB, 810-03201, 810-02901, CASTINS-CWL specifications

The Quadra-Fire 810-02901 and 810-03201, commonly referred to by their model designations CASTINS-CSB and CASTINS-CWL, represent a significant advancement in wood burning technology. These stoves are designed for efficiency, ease of use, and aesthetic appeal, catering to the increasing demand for sustainable and effective home heating solutions.

One of the standout features of these models is their high-efficiency combustion system. The technology employed in the Quadra-Fire 810 series optimizes fuel usage, ensuring that wood burns more completely. This not only maximizes heat output but also minimizes emissions, making it a more environmentally-friendly heating option compared to traditional wood stoves. By utilizing advanced combustion technology, these stoves can achieve higher efficiency ratings, which is essential for reducing heating costs and maintaining a comfortable indoor climate.

Both models come with a substantial firebox capacity, allowing users to load a significant amount of wood. This design feature ensures longer burn times and less frequent reloading, providing convenience for homeowners. The large viewing window creates an inviting ambiance and allows for a clear view of the mesmerizing flames, making these stoves a focal point in any living space.

The CASTINS-CSB model is particularly notable for its robust construction, featuring high-quality cast iron that provides excellent heat retention. This material not only contributes to durability but also enhances the overall thermal performance of the stove. The CASTINS-CWL model also incorporates a striking design with clean lines and a modern aesthetic, making it suitable for both traditional and contemporary home décor.

In terms of safety features, both models are equipped with advanced air control systems that facilitate easy adjustment of combustion airflow. This ensures safe operation and allows users to maintain optimal temperatures. The stoves are also designed to integrate with existing ventilation systems, promoting efficient airflow throughout the home.

Overall, the Quadra-Fire 810-02901 (CASTINS-CSB) and 810-03201 (CASTINS-CWL) models embody state-of-the-art wood burning technology with an emphasis on efficiency, quality, and design. These stoves are an ideal choice for homeowners looking to embrace a sustainable heating method without compromising on style or substance.