Quadra-Fire 810-02901, 810-03201 Castile Pellet Insert Feed Rate Adjustment, Iginition Cycles

Page 26

R

Castile Pellet Insert

F. Feed Rate Adjustment

The fuel adjustment control rod is factory set, and should be adequate for most fuels.

The set screw is located at the bottom of the hopper and

set loose at the factory so the fuel adjustment control rod will slide by only loosening the wing nut. Do not re-tighten bottom set screw.

However, if the flame height is too high or too low, you will need to adjust the feed rate. Wait until the appliance has been burning for 15 minutes before making your adjustments and allow 15 minutes for feed adjustment to take effect. Make adjustments in approximately 1/2 inch increments.

Fuse

Heat Output Switch

Red Call

Control Box

 

 

 

Light

 

 

 

 

 

 

Power Cord

 

 

 

Outlet

 

Blue

Light

 

 

 

 

Red/Green

Light

 

 

1.Loosen the wing nut. Figure 26.1.

2.Adjust the fuel adjustment control rod towards the

"+" symbol to increase the feed rate and fl ame height or

towards the "-" symbol, to decrease the feed rate and fl ame

Figure 26.1

 

height.

 

3. Re-tighten the wing nut.

 

Reset Button

Thermostat

Block

 

 

Junction Box

Wing Nut

"-"

WARNING

Fire Risk

Do NOT operate appliance:

With appliance door open.

Firepot fl oor open.

Cleaning slide plates open. Do NOT store fuel:

Closer than required clearances to com- bustibles to appliance

Within space required for loading or ash removal.

"+"

Figure 26.1

G. Iginition Cycles

1.During each ignition cycle, it is normal to see some smoke in the fi rebox. The smoke will stop once the fi re starts.

2.The convection blower will automatically turn on after your appliance has reached the set temperature. This blower transfers heat from your appliance into the room, and will continue to run after the thermostat has stopped calling for heat until the appliance has cooled down.

3.Occasionally the appliance may run out of fuel and shut itself down. When this happens, the red call light will be on. To restart it, fi ll the hopper and press the reset button. Figure 26.2. When you press the reset button the red call light will go out. Release the button and the light will come back on. You should see a fi re shortly. If not, follow the instructions on page 25, “Starting Your First Fire”.

Back side of Firepot

Firepot floor left open

Figure 26.2 - DO NOT LEAVE FIREPOT FLOOR OPEN

Page 26

250-7251G

August 20, 2009

Image 26
Contents 810-02901 MBK 810-03201 PMH Hot glass will cause burnsBuilding inspector, fi re Castile Pellet InsertInsurance carrier, local Inspection and permitsTable of Contents Mobile Home Approved Listing and Code ApprovalsAppliance Certification BTU & Efficiency Specifi cations Glass Specifi cationsGetting Started Appliance LocationNegative Pressure Castile Pellet Insert Locating Your Appliance & ChimneyDraft Inspect Appliance & Components and Pre-Use Check List Castile Pellet Insert Fire SafetyTools And Supplies Needed Height Width Panel Size Inch 3Dimensions and ClearancesAppliance Dimensions Shown Optional Outside Air Castile Pellet Insert Clearance To Combustibles, UL and ULC0mm Clearance To Exposed Section And Face Trim Inches MillimetersMinimum Opening for Masonry and Zero Clearance Fireplaces Castile Pellet Insert Masonry and Zero Clearance FireplacesFloor Protection Location Inches MillimetersStarter hole Mark area of floor to cut Castile Pellet Insert Prefabricated Metal Chimney Altering the Factory-Built FireplaceVenting Termination Requirements 4Vent InformationChimney and Exhaust Connection Example of 3 Elbow-Rear Vent Termination Calculation Pipe Selection ChartCastile Pellet Insert Equivalent Feet of Pipe Venting Systems Full Reline With Outside Air HorizontalCastile Pellet Insert Full Reline With Outside Air Vertical Mobile Home Installation 6Mobile Home7Appliance Set-Up Top Vent InstallationRear Vent Installation Reversible Top or Rear Flue Adapter Leveling SystemAssembled View Description20.3 Base Plate Only InstallationCastile Pellet Insert Zero Clearance Trim Support Cont’d 21.3 Panel Set And Cast Trim SetPanel & Trim Set, Econo Four Piece Log Set Installation Castile Pellet Insert Thermostat Installation 8Operating Instructions Fuel Size, Material and StorageBefore Your First Fire Fire CharacteristicsCastile Pellet Insert General Operating Information Starting Your First FireCastile Pellet Insert Feed Rate Adjustment Iginition CyclesFrequently Asked Questions Issues SolutionsTroubleshooting SymptomSymptom Possible Cause Corrective Action Page Types of Fuel Quick Reference Maintenance Chart10Maintaining & Servicing Your Appliance Frequency Daily Weekly Monthly YearlyNished. See .2 on Remove Cast Sides for Cleaning & MaintenanceCleaning Firepot with Cleaning Rod & Firepot Scraper Ash Removal from FireboxCleaning Beneath Heat Exchanger Cleaning Ash PanCleaning Heat Exchanger Chambers & Drop Tube Cleaning the Exhaust PathCleaning Exhaust Blower Requires No Lubrication Cleaning the HopperCleaning Convection Blower Requires No Lubrication Door Latch Inspection Cleaning the GlassPreparing Firebox for Non-Burn Season Frequency Yearly High Ash Fuel Content MaintenanceDoor Gasket Inspection Igniter Replacement Baffl e & Brick Set Removal 37.1Re-installing Baffl e & Brick Set Cont’d Component Function Snap Disc #1 Convection Blower 110F Vacuum SwitchWiring Harness See .1 below Snap Disc #2 Fuel Delivery Interrupt 250FCastile Pellet Insert Component Locations Blowers & Feed MotorCastile Pellet Insert Exploded Drawing 250-7251G August 20Castile Pellet Insert Service Parts and Accessories Important this is Dated Information HOW to OrderDescription Comments Part Number StockedAt Depot TOUCHUP-CSB Description ACCESSORIESComments Part Number PEL-DAMP4Description Comments Part Number Stocked at Depot FastenersCastile Pellet Insert Service And Maintenance Log Date of Service Performed By Description of ServiceCastile Pellet Insert Service And Maintenance Log Cont’d Castile Pellet Insert Warranty Policy Castile Pellet Insert Contact Information

CASTINS-CSB, 810-03201, 810-02901, CASTINS-CWL specifications

The Quadra-Fire 810-02901 and 810-03201, commonly referred to by their model designations CASTINS-CSB and CASTINS-CWL, represent a significant advancement in wood burning technology. These stoves are designed for efficiency, ease of use, and aesthetic appeal, catering to the increasing demand for sustainable and effective home heating solutions.

One of the standout features of these models is their high-efficiency combustion system. The technology employed in the Quadra-Fire 810 series optimizes fuel usage, ensuring that wood burns more completely. This not only maximizes heat output but also minimizes emissions, making it a more environmentally-friendly heating option compared to traditional wood stoves. By utilizing advanced combustion technology, these stoves can achieve higher efficiency ratings, which is essential for reducing heating costs and maintaining a comfortable indoor climate.

Both models come with a substantial firebox capacity, allowing users to load a significant amount of wood. This design feature ensures longer burn times and less frequent reloading, providing convenience for homeowners. The large viewing window creates an inviting ambiance and allows for a clear view of the mesmerizing flames, making these stoves a focal point in any living space.

The CASTINS-CSB model is particularly notable for its robust construction, featuring high-quality cast iron that provides excellent heat retention. This material not only contributes to durability but also enhances the overall thermal performance of the stove. The CASTINS-CWL model also incorporates a striking design with clean lines and a modern aesthetic, making it suitable for both traditional and contemporary home décor.

In terms of safety features, both models are equipped with advanced air control systems that facilitate easy adjustment of combustion airflow. This ensures safe operation and allows users to maintain optimal temperatures. The stoves are also designed to integrate with existing ventilation systems, promoting efficient airflow throughout the home.

Overall, the Quadra-Fire 810-02901 (CASTINS-CSB) and 810-03201 (CASTINS-CWL) models embody state-of-the-art wood burning technology with an emphasis on efficiency, quality, and design. These stoves are an ideal choice for homeowners looking to embrace a sustainable heating method without compromising on style or substance.