Napoleon Fireplaces NPI40 General Venting, Mobile Home, Type Of Vent, Installing The Pellet Vent

Page 12
MOBILE HOME

12

MOBILE HOME

Installation into a manufactured home or mobile home should be installed in accordance with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United States or the Mobile Home Standard, CAN/CSA Z240 MH Series, in Canada.

The heater must be grounded to the steel chassis of the mobile home (Some states do not require this; check with your local building department).

!WARNING

Do not install in a sleeping room.

The structural integrity of the manufactured home floor, wall, and ceiling roof

must be maintained.

Figure 5

GENERAL VENTING

PELLET VENT MUST MAINTAIN A MINIMUM 3" CLEARANCE TO ANY COMBUSTIBLE (install vent at clearances specifi ed by the vent manufacturer).

DO NOT CONNECT THE PELLET VENT TO A VENT OR CHIMNEY SERVING ANY OTHER APPLIANCE OR HEATER. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.

TYPE OF VENT

Must be an approved 3" or 4" Diameter Type "L" or "PL" vent, vented to the outside or connect the vent to a factory built type "A" chimney using an adaptor; and/or stainless steel chimney liner for masonry fi replace installations. Use 4" diam- eter vent if vent or liner height is over 15' or if installation is over 4,000' above sea level.

INSTALLING THE PELLET VENT

The vent must have a support bracket every 5' when on the exterior wall.

To achieve optimum performance, keep vent runs as short as possible, especially on horizontal installations.

MAXIMUM VENTING:

Maximum venting height is 33'. Maximum horizontal offset is 10'. Use no more than 180° of elbows (two 90' elbows, or two 45' elbows and one 90' elbow, etc), plus termination.

VENT INSTALLATION:

Termination must exhaust above the air inlet elevation, and parallel or above the exhaust output of the pellet appliance. It is recommended that at least 3' of vertical pipe be installed to create some natural draft. This is to help prevent the possibility of smoke or odour during the appliance shut down or in the event of a power out- age.

Horizontal sections must have a 1/4" rise every 12" of travel if longer than 3'.

The pellet vent connections must be sealed with HI-Temp RTV Silicone and screwed together with at least 3 3/8" long stainless steel screws.

Seal each vent section by injecting a liberal amount of 500°F (260°C) RTV silicone sealant into the gap. We recommend sealing the outside of the vent connections to permit easier access when servicing.

Figure 6

W415-0616 / C / 06.04.08

Image 12
Contents W415-0616 /C $10.00W415-0616 /C TABLE of CONTENTS PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCEWARRANTY CONDITIONS AND LIMITATIONSWARNINGS AND SAFETY PRECAUTIONS W415-0616 /CWARNINGS AND SAFETY PRECAUTIONS W415-0616 /CSPECIFICATIONS HEATING SPECIFICATIONS GENERAL INTRODUCTIONGENERAL INSTRUCTIONS PELLET QUALITYDIMENSIONS Figures 1a-bFigures 2a-c DIMENSIONS CONTINUED Figures 3a-cDIMENSIONS CONTINUED Figures 4a-cNPI40 with AK8 Adapter and GICSK Flashing Shown GENERAL INSTALLATION SPECIFICATIONSPLANNING YOUR INSTALLATION HEATER PLACEMENTINSTALLATION OPTIONS SAFETY FEATURESFLOOR PROTECTION REQUIREMENTS OUTSIDE AIRINSTALLING THE PELLET VENT GENERAL VENTINGMOBILE HOME TYPE OF VENTALCOVE INSTALLATION NPS40 ONLY VENTING THE PELLET HEATERPELLET VENT TERMINATION Minimum Alcove DimensionsMINIMUM AIR TERMINAL INSTALLATIONS J D ABBFI LG H ENPS40 INSTALLATION STRAIGHT INSTALLATIONCORNER INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLESVENTING INSTALLATION EXAMPLES HORIZONTAL EXHAUST THROUGH WALL INSTALLATIONTERMINATION INSTALLATION THROUGH WALL WITH VERTICAL RISE AND HORIZONTALMINIMUM INSIDE VERTICAL CLEARANCES CLASS A CHIMNEY RETROFITHEARTH MOUNT INSTALLATION PRIOR TO INSTALLATIONINSTALLATIONINTOAMASONRYFIREPLACE RecommendedNPI40 INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLESMINIMUM MANTEL CLEARANCES REAR TO TOP VENT CONVERSION INSTRUCTIONSNPI40 INSTALLATION OVERVIEW INSTALLATION INTO A MASONRY FIREPLACE HORIZONTAL VENT INSTALLATIONVERTICAL LINER INSTALLATION PRIOR TO INSTALLATIONINSTALLATION INTO A FACTORY BUILT METAL FIREPLACE LINER INSTALLATIONPRIOR TO INSTALLATION INSTALLATION INTO A MASONRY FIREPLACEINSTALLATION INTO A COMBUSTIBLE BUILT-INENCLOSURE MINIMUM FRAMING DIMENSIONSFigure 24a Figure 24bFLASHING INSTALLATION NPI40 FINISHINGMINIMUM ENCLOSURE CLEARANCES INSTALL VIEWING DOOR NPS40 AND NPI40 TRIVET NPI40LIGHTING HEATER MANUALLY PROPER PELLET LOADINGOPERATING INSTRUCTIONS START-UPSHUT-DOWN GENERAL MAINTENANCE NPS40 AND NPI40 DAILY WHENEVER USING THE HEATERCLEANING GLASS DOOR OPEN MAIN VIEWING DOORCLEANING THE HEAT EXCHANGE TUBES MAKE SURE PELLETS ARE NOT PILING UPCLEANING THE BURN POT BI-WEEKLYOR EVERY 10 BAGS OF PELLETSVACUUM FIREBOX SEMI-ANNUALLYOR EVERY TWO TONS OF PELLET VACUUM HOPPERSOOT AND FLY ASH FORMATION CLEAN THE VERTICAL EXHAUST DUCT CLEAN EXHAUST HOUSING INSERT ONLYCLEAN THE EXHAUST BLOWER SEMI-ANNUALLYOR EVERY TWO TONS OF PELLETCLEAN THE VENT CHECK ALL SEALSNORMAL OPERATING SOUNDS WIRING DIAGRAM REPLACEMENTS COMMON ACCESSORIESNPS40 ACCESSORIES NPI40 ACCESSORIESCOMMON REPLACEMENTS PARTS W415-0616 /CNPS40 REPLACEMENTS PARTS W415-0616 /CNPI40 REPLACEMENTS PARTS W415-0616 /CNPI40 ACCESSORY PARTS COMMON ACCESSORY PARTSTROUBLESHOOTING SYMPTOMTEST SOLUTION TROUBLESHOOTING CONTINUED SYMPTOMTEST SOLUTION TROUBLESHOOTING CONTINUED SYMPTOMTEST SOLUTION Burn pot is cleanSERVICE AND MAINTENANCE LOG SERVICE DATESERVICE TECHNICIAN SERVICE DESCRIPTIONW415-0616 /C