Napoleon Fireplaces NPS40, NPI40 manual Cleaning The Burn Pot, BI-WEEKLYOR EVERY 10 BAGS OF PELLETS

Page 29
CLEANING THE BURN POT

29

CLEANING THE BURN POT

!WARNING

Make certain the heater has fully cooled (approximately 25 minutes) before opening the door and conducting service.

To clean the burn pot, open the door and knock away any debris on the burn

 

Figure 40

pot. If severely clogged, remove the burn pot to gain better access.

 

 

If removing the burn pot set aside on a non-combustible surface. See Figure

 

40. Once removed, discard all material that has accumulated in the burn pot.

 

Make certain that all openings are clear of any build up of ash from the ledge

 

below the burn pot.

 

Re-install the burn pot ensuring it sits level in the heater. Also must ensure the ignitor and the burn pot locating notch line up when reinstalling the burn pot.

LOCATING NOTCH

IGNITOR

BI-WEEKLY (OR EVERY 10 BAGS OF PELLETS)

VACUUM FIREBOX

The more frequently you clean out the fl y ash, the more effi cient your heater will burn.

!WARNING

The fire box becomes very hot during operation. Let the heater cool completely before conducting service.

1.Open the viewing door. See Figure 35 and 36

2.Lift the burn pot out and set aside on a non-combustible surface.

See Figure 40. Remove the right and left louvres by lifting the louvres up and out of the fi rebox setting them on a non-combustible surface.

LOUVRES BI-WEEKLY (OR EVERY 10 BAGS OF PELLETS)

FIREBOX AIR HOUSING

Figure 41

W415-0616 / C / 06.04.08

Image 29
Contents W415-0616 /C W415-0616 /C$10.00 PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE TABLE of CONTENTSCONDITIONS AND LIMITATIONS WARRANTYW415-0616 /C WARNINGS AND SAFETY PRECAUTIONSW415-0616 /C WARNINGS AND SAFETY PRECAUTIONSGENERAL INTRODUCTION SPECIFICATIONS HEATING SPECIFICATIONSGENERAL INSTRUCTIONS PELLET QUALITYFigures 2a-c DIMENSIONSFigures 1a-b Figures 3a-c DIMENSIONS CONTINUEDNPI40 with AK8 Adapter and GICSK Flashing Shown DIMENSIONS CONTINUEDFigures 4a-c SPECIFICATIONS GENERAL INSTALLATIONPLANNING YOUR INSTALLATION HEATER PLACEMENTSAFETY FEATURES INSTALLATION OPTIONSFLOOR PROTECTION REQUIREMENTS OUTSIDE AIRGENERAL VENTING INSTALLING THE PELLET VENTMOBILE HOME TYPE OF VENTVENTING THE PELLET HEATER ALCOVE INSTALLATION NPS40 ONLYPELLET VENT TERMINATION Minimum Alcove DimensionsJ D ABBFI LG H E MINIMUM AIR TERMINAL INSTALLATIONSSTRAIGHT INSTALLATION NPS40 INSTALLATIONCORNER INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLESHORIZONTAL EXHAUST THROUGH WALL INSTALLATION VENTING INSTALLATION EXAMPLESTERMINATION INSTALLATION THROUGH WALL WITH VERTICAL RISE AND HORIZONTALCLASS A CHIMNEY RETROFIT MINIMUM INSIDE VERTICAL CLEARANCESPRIOR TO INSTALLATION HEARTH MOUNT INSTALLATIONINSTALLATIONINTOAMASONRYFIREPLACE RecommendedMINIMUM CLEARANCES TO COMBUSTIBLES NPI40 INSTALLATIONMINIMUM MANTEL CLEARANCES REAR TO TOP VENT CONVERSION INSTRUCTIONSNPI40 INSTALLATION OVERVIEW HORIZONTAL VENT INSTALLATION INSTALLATION INTO A MASONRY FIREPLACEVERTICAL LINER INSTALLATION PRIOR TO INSTALLATIONLINER INSTALLATION INSTALLATION INTO A FACTORY BUILT METAL FIREPLACEPRIOR TO INSTALLATION INSTALLATION INTO A MASONRY FIREPLACEMINIMUM FRAMING DIMENSIONS INSTALLATION INTO A COMBUSTIBLE BUILT-INENCLOSUREFigure 24a Figure 24bMINIMUM ENCLOSURE CLEARANCES FLASHING INSTALLATIONNPI40 FINISHING TRIVET NPI40 INSTALL VIEWING DOOR NPS40 AND NPI40LIGHTING HEATER MANUALLY PROPER PELLET LOADINGSHUT-DOWN OPERATING INSTRUCTIONSSTART-UP DAILY WHENEVER USING THE HEATER GENERAL MAINTENANCE NPS40 AND NPI40CLEANING GLASS DOOR OPEN MAIN VIEWING DOORMAKE SURE PELLETS ARE NOT PILING UP CLEANING THE HEAT EXCHANGE TUBESVACUUM FIREBOX CLEANING THE BURN POTBI-WEEKLYOR EVERY 10 BAGS OF PELLETS SOOT AND FLY ASH FORMATION SEMI-ANNUALLYOR EVERY TWO TONS OF PELLETVACUUM HOPPER CLEAN EXHAUST HOUSING INSERT ONLY CLEAN THE VERTICAL EXHAUST DUCTCLEAN THE EXHAUST BLOWER SEMI-ANNUALLYOR EVERY TWO TONS OF PELLETCHECK ALL SEALS CLEAN THE VENTNORMAL OPERATING SOUNDS WIRING DIAGRAM COMMON ACCESSORIES REPLACEMENTSNPS40 ACCESSORIES NPI40 ACCESSORIESW415-0616 /C COMMON REPLACEMENTS PARTSW415-0616 /C NPS40 REPLACEMENTS PARTSW415-0616 /C NPI40 REPLACEMENTS PARTSCOMMON ACCESSORY PARTS NPI40 ACCESSORY PARTSTEST SOLUTION TROUBLESHOOTINGSYMPTOM TEST SOLUTION TROUBLESHOOTING CONTINUEDSYMPTOM SYMPTOM TROUBLESHOOTING CONTINUEDTEST SOLUTION Burn pot is cleanSERVICE DATE SERVICE AND MAINTENANCE LOGSERVICE TECHNICIAN SERVICE DESCRIPTIONW415-0616 /C
Related manuals
Manual 40 pages 42.1 Kb