Napoleon Fireplaces manual NPI40 FINISHING, Minimum Enclosure Clearances, Flashing Installation

Page 24
MINIMUM ENCLOSURE CLEARANCES

24

MINIMUM ENCLOSURE CLEARANCES

Figure 25

NPI40 FINISHING

FLASHING INSTALLATION

1.Secure the Right Flashing to the right side of the unit using two of the #8 x 1/2" screws.

FIGURE 26 NPI40 FINISHING

NOTE: Feed the Air Control Rod into the Air Control Slot on the Right Flashing before securing. (FIGURE 26)

2.

Twist spring handle (supplied with

 

the heater) onto the air control rod

 

until it hits the stop.

3.

Remove the two control panel

 

securing screws, discard the screws

 

and shipping bracket. (FIGURE 27)

4.

Secure the control panel to the Right

 

Flashing using the two #8 x 3/8" screws.

AIR

CONTROL

ROD

AIR

CONTROL

SLOT

L

 

O

1

W

2

3 4

SHIPPING

CONTROL

BRACKET

PANEL

SECURING

SECURING

SCREWS

SCREWS

FIGURE 27

CONTROL

PANEL

RIGHT

FLASHING

5 IH G H

FLASHING INSTALLATION BURN

RATE LABEL

(FIGURE 20) Secure the Left Flashing

with the remaining #8 x 1/2" screws.

(FIGURE 26)

5. Align the holes in the top of the Right and

Left Flashing with those on the bottom lip

of the Top Flashing and secure from the

rear using the four #8-32 x 3/8" screws,

washers and nuts. (FIGURE 29)

FIGURE 28

FIGURE 29

TOP

FLASHING

6.The three pieces of trim are assembled in

the same manner as a picture frame. Place the corner brackets (with screw loosened) into the trim sections. Tighten the screw spreading the two pieces apart. Attach the adjoining section. Repeat with the opposite side. Tighten all screws fi rmly.

(FIGURE 30)

7.Slide the assembled trim down over the fl ashing.

(FIGURE 31)

FIGURE 30

FIGURE 31

TRIM

ASSEMBLY

8.Affi x the logo to the bottom left hand corner of the left fl ashing.

W415-0616 / C / 06.04.08

Image 24
Contents W415-0616 /C $10.00W415-0616 /C TABLE of CONTENTS PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCEWARRANTY CONDITIONS AND LIMITATIONSWARNINGS AND SAFETY PRECAUTIONS W415-0616 /CWARNINGS AND SAFETY PRECAUTIONS W415-0616 /CSPECIFICATIONS HEATING SPECIFICATIONS GENERAL INTRODUCTIONGENERAL INSTRUCTIONS PELLET QUALITYDIMENSIONS Figures 1a-bFigures 2a-c DIMENSIONS CONTINUED Figures 3a-cDIMENSIONS CONTINUED Figures 4a-cNPI40 with AK8 Adapter and GICSK Flashing Shown GENERAL INSTALLATION SPECIFICATIONSPLANNING YOUR INSTALLATION HEATER PLACEMENTINSTALLATION OPTIONS SAFETY FEATURESFLOOR PROTECTION REQUIREMENTS OUTSIDE AIRINSTALLING THE PELLET VENT GENERAL VENTINGMOBILE HOME TYPE OF VENTALCOVE INSTALLATION NPS40 ONLY VENTING THE PELLET HEATERPELLET VENT TERMINATION Minimum Alcove DimensionsMINIMUM AIR TERMINAL INSTALLATIONS J D ABBFI LG H ENPS40 INSTALLATION STRAIGHT INSTALLATIONCORNER INSTALLATION MINIMUM CLEARANCE TO COMBUSTIBLESVENTING INSTALLATION EXAMPLES HORIZONTAL EXHAUST THROUGH WALL INSTALLATIONTERMINATION INSTALLATION THROUGH WALL WITH VERTICAL RISE AND HORIZONTALMINIMUM INSIDE VERTICAL CLEARANCES CLASS A CHIMNEY RETROFITHEARTH MOUNT INSTALLATION PRIOR TO INSTALLATIONINSTALLATIONINTOAMASONRYFIREPLACE RecommendedNPI40 INSTALLATION MINIMUM CLEARANCES TO COMBUSTIBLESMINIMUM MANTEL CLEARANCES REAR TO TOP VENT CONVERSION INSTRUCTIONSNPI40 INSTALLATION OVERVIEW INSTALLATION INTO A MASONRY FIREPLACE HORIZONTAL VENT INSTALLATIONVERTICAL LINER INSTALLATION PRIOR TO INSTALLATIONINSTALLATION INTO A FACTORY BUILT METAL FIREPLACE LINER INSTALLATIONPRIOR TO INSTALLATION INSTALLATION INTO A MASONRY FIREPLACEINSTALLATION INTO A COMBUSTIBLE BUILT-INENCLOSURE MINIMUM FRAMING DIMENSIONSFigure 24a Figure 24bFLASHING INSTALLATION NPI40 FINISHINGMINIMUM ENCLOSURE CLEARANCES INSTALL VIEWING DOOR NPS40 AND NPI40 TRIVET NPI40LIGHTING HEATER MANUALLY PROPER PELLET LOADINGOPERATING INSTRUCTIONS START-UPSHUT-DOWN GENERAL MAINTENANCE NPS40 AND NPI40 DAILY WHENEVER USING THE HEATERCLEANING GLASS DOOR OPEN MAIN VIEWING DOORCLEANING THE HEAT EXCHANGE TUBES MAKE SURE PELLETS ARE NOT PILING UPCLEANING THE BURN POT BI-WEEKLYOR EVERY 10 BAGS OF PELLETSVACUUM FIREBOX SEMI-ANNUALLYOR EVERY TWO TONS OF PELLET VACUUM HOPPERSOOT AND FLY ASH FORMATION CLEAN THE VERTICAL EXHAUST DUCT CLEAN EXHAUST HOUSING INSERT ONLYCLEAN THE EXHAUST BLOWER SEMI-ANNUALLYOR EVERY TWO TONS OF PELLETCLEAN THE VENT CHECK ALL SEALSNORMAL OPERATING SOUNDS WIRING DIAGRAM REPLACEMENTS COMMON ACCESSORIESNPS40 ACCESSORIES NPI40 ACCESSORIESCOMMON REPLACEMENTS PARTS W415-0616 /CNPS40 REPLACEMENTS PARTS W415-0616 /CNPI40 REPLACEMENTS PARTS W415-0616 /CNPI40 ACCESSORY PARTS COMMON ACCESSORY PARTSTROUBLESHOOTING SYMPTOMTEST SOLUTION TROUBLESHOOTING CONTINUED SYMPTOMTEST SOLUTION TROUBLESHOOTING CONTINUED SYMPTOMTEST SOLUTION Burn pot is cleanSERVICE AND MAINTENANCE LOG SERVICE DATESERVICE TECHNICIAN SERVICE DESCRIPTIONW415-0616 /C