MOBILE HOME INSTALLATION

MODEL 1600C-1 IS APPROVED FOR INSTALLATION IN MOBILE HOMES IN BOTH CANADA AND THE UNITED STATES.

The stove must be secured to the floor of the mobile home.

Warning!

Do not install this stove in a bedroom/sleeping room. Do not install the stove in any way that might compromise the structural integrity of the mobile home floor, walls, ceiling, or roof.

Venting

Connect the stove to a chimney system using a

l i s t e d

d o u b l e

w a l l

SOLINDETOIT

connector with a minimum

POURMAISONMOBIL

 

clearance rating of 12” or

ÉCRANDEPROTECTIO

less. Use chimney system

 

l i s t e d t o

U L C S 6 2 9 i n

CEILINGSUPPORT

Canada or UL103HT in the

TRIMCOLLAR

USA.

 

 

 

T h e c h i m n e y m u s t b e

STOVEBOLTED

TOFLOOR

 

 

installed

in accordance

 

with the

manufacturer ’s

 

i n s t r u c t i o n s . U s e o n l y

 

specified components with

HEARTHPAD

 

n o s u b s t i t u t i o n s . T h e

 

chimney and pipe must

 

e x t e n d a t l e a s t 8 f e e t

OUTSIDEAIRCONNECTIONTHROUGH

above the stove and 3 feet

WALLORFLOOR

above the highest point of

the roof. Install a rain cap at the top which will not impede the smoke exhaust. The chimney must be supported at the ceiling or roof so that its weight does not rest on the stove.

It must be installed between ceiling joists, with radiation shield and roof flashing, so that the structural strength, insulation and waterproof qualities of the home are not lessened. Seal with silicone to maintain a vapour barrier at the chimney and outside air pipe penetrations.

Outside air / Floor Securing

Connecting the stove’s air intake to the outside as well as securing the unit to the floor, is mandatory in mobile homes only. Use a fresh air kit and the floor securing brackets.

Avoid cutting away floor joists, wall studs, electrical wires or plumbing. Seal around the outside pipe with insulation to prevent drafts.

If room air starvation occurs because the fresh air intake is blocked with ice, leaves, etc., or because the stove door was left open, or due to a strong exhaust fan operating etc., dangerous fumes and smoke from the operating stove could be drawn into the room.

113KT 1600C-1 Adaptor Kit Intallation

When installing the 1600C-1 in a mobile home,use the 111KT Outside air kit in conjunction with the 113KT Outside Air Adaptor Kit.

Remove the two screws from the bottom of the unit and install the two floor securing brackets using the two screws removed.

Install the vent connector by inserting the stud retainer into the hole in the bottom of the fireplace. Position the retainer so that the studs come through the holes indicated.

Hold the retainer in place and align the holes in the vent connector with the studs of the retainer.

Secure the vent connector in place using the 2 nuts supplied. Secure the unit to the floor using the securing brackets and the two #10x1.5" screws supplied.

8

Image 8
Contents For Your Safety Fax Email ask@napoleon.on.caConditions and Limitations Table of Contents Introduction General informationPrincipal of operation Care of glassStove installation InstallationAlcove installation Installation When Installed with Blower KIT EP63 Ash fender installation Heat shield installationChimney connection Adding chimney sections Outside air Flue collar reversal113KT 1600C-1 Adaptor Kit Intallation VentingOutside air / Floor Securing Achieving proper draft When lit for the first timeOperating Instructions Ash removal procedures Fire extinguishers / smoke detectorsFuel loading and burn cycle EP63 Optional Blower KITWood Pile Maintenance Stove MaintenanceCreosote formation and removal Runaway or chimney fireOrdering Procedures Code Description QtyAccessories Page Modèle 1600C-1 Pour Votre SécuritéLA Garantie DU Président Conditions ET LimitationsPoids SpécificationsModèle 1600C-1 Informations générales Principe de fonctionnementSoin de la vitre Nettoyez Seulement Lorsque LA Vitre EST FroideInstallation dans une alcôve Installation du poêlePoêle ConduitInstallation Avec LE KIT Soufflerie EP63 Installation du récupérateur de cendre Installation de l’écran de dessousRaccordement de la cheminée Ajout de sections de cheminéeInstallation Dans UNE Maison Mobile ’évacuationAir extérieur/fixation au plancher Adaptateur pour prise d’air extérieur 113KTLors du premier allumage Créer un tirage appropriéExtincteurs et détecteurs de fumée Soufflerie optionnelle EP63Méthodes de décendrage Pare-étincelles optionnel EP90KEntretien DU TAS DE Bois Entretien DU PoêleFormation et enlèvement de créosote Feu de cheminée ou feu hors contrôleRemplacements Accessoires Diam