RDV4136 Series Direct Vent Gas Fireplace
General Venting
Your fireplace is approved to be vented either through the side wall, or vertically through the roof.
•Only CFM Corporation venting components spe- cifically approved and labelled for this fireplace may be used.
•Vent terminations shall not be recessed into a wall or siding.
•Horizontal venting which incorporates the twist lock pipe must be installed on a level plane without an inclining or declining slope.
•Horizontal venting which incorporates the use of flex venting shall have an inclining slope from the unit of 1” (25 mm) per 24” (610 mm).
There must not be any obstruction such as bushes, garden sheds, fences, decks or utility buildings within 24” (610 mm) from the front of the termination hood.
Do not locate termination hood where excessive snow or ice build up may occur. Be sure to check vent termi- nation area after snow falls, and clear to prevent ac- cidental blockage of venting system. When using snow blowers, make sure snow is not directed towards vent termination area.
Location of Vent Termination
It is imperative the vent termination be located observ- ing the minimum clearances as shown on the next page.
*Check with local codes or in absence of same with
10 | 10010618 |