EB-1 Electrical Box
The fireplace, when installed, must be elec- trically connected and grounded in accord- ance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electrical Code.
For USA installations follow local codes and the national electrical code ANSI/ NFPA No. 70.
It is strongly suggested that the wiring of the
Ensure that the power to the supply line has been disconnected before commenc- ing this procedure.
The
RDV4136 Series Direct Vent Gas Fireplace
To connect the
1.Unscrew retaining screw from
2.Remove the front cover of the EB box.
3.Remove the plug socket assembly from the
4.Feed the supply line in through the
5.Connect the black wire of the power supply line to the brass screw (polarized) of the socket assembly.
6.Connect the white wire of the power line to the chrome screw of the socket assembly.
7.Connect the ground wire of the supply line to the green screw of the socket assembly.
8.Refit the socket assembly back into the electrical box and replace the cover plate. Secure the cable with the clamp on the outside of the
INSIDE | ElectricalBox Box |
| |
| Retaining Screw |
FRONT |
|
OF UNIT |
|
OUTSIDE |
|
OF | UNIT |
|
FRONT
FP580
Fig. 8 EB-1 receptacle.
10010618 | 9 |