Majestic Appliances RDV4136 Troubleshooting AF4000 Valve, Igniter operation

Page 28

RDV4136 Series Direct Vent Gas Fireplace

Troubleshooting AF4000 Valve (continued)

Pilot will not light/stay lit

Verify the gas supply is turned on.

 

Verify the receiver is receiving the signal from the transmitter by listening for a

 

beep from the receiver when ON is pressed on the transmitter. If you do not hear

 

a beep, ensure the module has learned the transmitter (see above).

 

Ensure the orange lead from the pilot assembly igniter is securely connected to

 

the terminal labeled “I” and the white lead from the flame rectification sensor is

 

securely connected to the terminal labeled “S” on the control module. (Fig. 45)

 

Make sure the orange and white leads from the module are securely connected to

 

the terminals labeled “PILOT” on the valve body. (Fig. 48)

 

Ensure the black GROUND wire is securely connected to an appropriate metal

 

portion of the valve or pilot assembly. A proper ground is essential to spark

 

igniter operation.

 

 

Make certain the pilot flame is in contact with the flame rectification sensor on the

 

pilot assembly. This valve is equipped with a pilot flame adjustment screw. (Fig.

 

48) If the pilot flame is too small it will not contact the flame rectification sensor

 

and will not complete the safety circuit.

Figure 47: AF4000 MOD Module End

8 Pin IPI

 

6 Volt DC Adapter

Connection

 

 

Power Connection

FP1764

28

10010618

Image 28
Contents Builder Top Vent Direct Vent Models RDV4136 Table of Contents RDV4136 Certified To Installation & Operating InstructionsAnsi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Requirements for the Commonwealth of Massachusetts Gas Equipment Venting System not ProvidedFireplace Dimensions Mantel Chart Locating Your FireplaceClearance to Combustibles MantelsGas Line Installation HearthFraming and Finishing Final FinishingInstallation RN/RP Models Remote ON/OFF SwitchInstallation IN/IP Models EB-1 Electrical Box EB-1 receptacleGeneral Venting Location of Vent TerminationCanadian Installations1 US Installations2 General Venting Information Termination LocationCanadian Installations USA InstallationsGeneral Information on Assembling Vent Pipes Flex Vent PipesHow to Use the Vent Graph Twist Lock PipesExample a Example BInstall baffle to the deflector Vertical Sidewall ApplicationsVertical Sidewall Installation Twist Lock Pipe Zero clearance sleeve is only required for combustible wallsAlways install horizontal venting on a level plane Vertical height requirementBelow Grade Installations Vertical Sidewall Installation Flex Vent PipeStep Vertical Through-the-Roof Installation Vertical Through-the-Roof ApplicationsMin 610 mm Venting Components Window Frame Assembly Removal Glass CleaningOperating Instructions Glass InformationInstallation of Logs, Lava Rock & Ember Material Log InstallationLog Identification Chart LogsEmber Material Left Cross Log Right Cross Log Rear Log Front Flame Characteristics Correct pilot flame appearanceFor Fireplaces Equipped with the SIT 820 Valve Lighting and Operating InstructionsTo Turn Off Gas To Heater Lighting & Operating Instructions For Fireplaces equipped with AF4000 Gas ValveLighting Instructions Turning Off the Gas to the ApplianceTroubleshooting AF4000 ValveTroubleshooting AF4000 Valve Igniter operationAF4000 Valve Face Troubleshooting Honeywell VS8421 Remove Window Frame Assembly Before Service WorkSkyTech Valve Burner Orifice ConversionNova SIT820 Valve Pilot Orifice Conversion Injector Orifice Size MatrixMaintenance Cleaning the Standing Pilot Control SystemLogs May Be HOT Burner and Burner CompartmentRDV4136 Units GFSJ5J1RP RDV4136 Description RDV4136Fuel Conversion Kits Optional Accessories Fan AssemblyHard direct Wire Hook Up Wiring InstructionsRemote Controls Back-up Battery KitCeramic Refractory Panels Porcelain Steel BackLimited Lifetime Warranty Efficiency Ratings