Majestic Appliances RDV4136 Optional Accessories, Fan Kits, Fan Assembly, Wiring Instructions

Page 37

RDV4136 Series Direct Vent Gas Fireplace

Optional Accessories

Fan Kits

Installation of the fan kit is best completed prior to installing the fireplace. If done after the fireplace is installed, all lava rocks must be fully removed so the

burner tray can be easily lifted out.

Fan Assembly

Heat SensorFan

 

��

����

��

 

���

���

 

Electrical Box

1.

Remove valve access panel.

2.

Turn OFF the electricity and turn OFF the manual

 

gas valve.

3.

Remove the glass door.

4.

Remove the log set, embers and lava rock.

5.

Remove the rear log support.

6.

Remove the 10 sheet metal screws and two (2) 1/4-

 

20 bolts that secure the burner tray to the combus-

 

tion casing.

7.

Remove the burner tray from the fireplace by first tilt-

 

ing up the back. Take care not to damage the formed

 

burner tray gasket. If the gasket is damaged, replace

 

it with Part # 10010592.

8.

While holding the burner tray, remove the flex gas

 

line from the shut-off valve (turned OFF in Step 2).

Fan Speed

Gas Line

Valve

FP1811

Switch

 

 

 

Fig. 58 FK24 fan placement.

Hard (direct) Wire Hook Up

First connect ground wire to ground stud located on the base of either box. Black wire from supply should connect to the variable speed switch. Alternate speed switch wire connects to temperature sensor. Alternate lead from sensor connects to fan. Alternate fan lead connects back to the white supply wire. (Fig. 59)

Any electrical rewiring of this fan must be completed by a qualified electrician.

Turn off all power before hook up.

9. FK12: Fig. 57

Secure fan to cold air box and plug fan into EB-1.

Reassemble fireplace in reverse order. Use a 50/50

soap and water solution to check for leaks.

Side View

Cold Air Box

Temperature

Sensor

Speed

Control

Black

White

Ground

Fig. 59 FK24 fan wiring.

Fan

FP1025

Front of

Unit

Hearth Pan

FK12 Fan

Base Pan

FP1004

Fig. 57 FK12 Fan Kit placement.

FK24: Fig. 58

Secure fan to cold air box with two (2) washers and nuts provided. Secure the fan speed switch with two

(2)nuts provided to the two (2) studs on the base

pan of the fireplace. Lay the burner tray upside down in front of the fireplace. Secure the heat sensor over the two (2) studs on the underside of the burner tray assembly and secure with two (2) nuts provided. Re- assemble the fireplace in reverse order. Use a 50/50 soap and water solution to check for gas leaks.

Fan installation complete.

Wiring Instructions

The fireplace, when installed, must be electrically connected and grounded in accordance with local codes or, in the absence of local codes, with the current CSA C22.1 Canadian Electric Code.

For USA installations follow the local codes and the national electrical code ANSI/NFPA No. 70.

Should this fan require servicing or repair the power supply must be disconnected. For rewiring of any replacement parts refer to Figure 59.

Any electrical re-wiring of this fan must be done by a licensed electrician.

10010618

37

Image 37
Contents Builder Top Vent Direct Vent Models RDV4136 Table of Contents RDV4136 Certified To Installation & Operating InstructionsAnsi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsFireplace Dimensions Locating Your Fireplace Mantel ChartClearance to Combustibles MantelsHearth Gas Line InstallationFraming and Finishing Final FinishingInstallation RN/RP Models Remote ON/OFF SwitchInstallation IN/IP Models EB-1 receptacle EB-1 Electrical BoxLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2USA Installations Canadian InstallationsGeneral Information on Assembling Vent Pipes Flex Vent PipesTwist Lock Pipes How to Use the Vent GraphExample a Example BVertical Sidewall Applications Install baffle to the deflectorZero clearance sleeve is only required for combustible walls Vertical Sidewall Installation Twist Lock PipeVertical height requirement Always install horizontal venting on a level planeBelow Grade Installations Vertical Sidewall Installation Flex Vent PipeStep Vertical Through-the-Roof Applications Vertical Through-the-Roof InstallationMin 610 mm Venting Components Glass Cleaning Window Frame Assembly RemovalOperating Instructions Glass InformationLog Installation Installation of Logs, Lava Rock & Ember MaterialLog Identification Chart LogsEmber Material Left Cross Log Right Cross Log Rear Log Front Correct pilot flame appearance Flame CharacteristicsFor Fireplaces Equipped with the SIT 820 Valve Lighting and Operating InstructionsTo Turn Off Gas To Heater For Fireplaces equipped with AF4000 Gas Valve Lighting & Operating InstructionsLighting Instructions Turning Off the Gas to the ApplianceAF4000 Valve TroubleshootingIgniter operation Troubleshooting AF4000 ValveAF4000 Valve Face Remove Window Frame Assembly Before Service Work Troubleshooting Honeywell VS8421SkyTech Valve Burner Orifice ConversionNova SIT820 Valve Injector Orifice Size Matrix Pilot Orifice ConversionCleaning the Standing Pilot Control System MaintenanceLogs May Be HOT Burner and Burner CompartmentRDV4136 Units GFSJ5J1RP Description RDV4136 RDV4136Fuel Conversion Kits Fan Assembly Optional AccessoriesHard direct Wire Hook Up Wiring InstructionsBack-up Battery Kit Remote ControlsCeramic Refractory Panels Porcelain Steel BackLimited Lifetime Warranty Efficiency Ratings