Majestic Appliances RDV4136 Burner Orifice Conversion, SkyTech Valve, Nova SIT820 Valve

Page 31

RDV4136 Series Direct Vent Gas Fireplace

Conversions must be completed by qualified personnel

Fuel Conversion Instructions Tighten the screws securely. (Ref. torque = 25 in/lb) (Fig. 51)

To convert the RDV4136 units for use with a different gas follow these instructions. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance.

CAUTION: Logs may be HOT! Allow to cool before proceeding.

1.Remove valve access panel to gain access to valve. Remove window frame assembly. (See “Window Frame Assembly Removal”, Page 21, Fig. 38)

2.Remove logs if previously installed.

3.Install the enclosed conversion label (F) to the valve body where it can easily be seen. (Fig. 51)

Valve conversion is complete.

E

SkyTech Valve

1.Remove rubber cap from valve. (Fig. 49)

2.Push pin in and turn so line on the end of the pin lines up with the appropriate gas. NAT for natural gas and LP for propane.

3.Replace cap.

4.Remove minimum rate screw and replace with new minimum rate screw supplied in kit. Refer to Table 1 on Page 32.

N

O

F

OFF

P

 

L

I

TO

 

D

FC108

Main Connection

MAIN

Inlet

 

 

��

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Adj.

 

 

 

 

 

 

 

 

 

 

 

 

 

PILOT

 

 

 

 

 

 

 

 

 

 

 

Outlet

 

 

 

 

 

 

Rubber Cap

Minimum

Gas Type

 

Marker

 

FP1769a

Rate Screw

CO137

Fig. 49 Remove rubber cap and adjust gas type marker.

Fig. 51 Replace ignitor.

Burner Orifice Conversion

1. Remove two (2) burner screws. (Fig. 52)

2. Remove burner housing assembly. (Fig. 52)

3. Remove burner orifice from manifold assembly using 7/16” wrench. (Fig. 52)

Rear Log Support

Pilot

Location

NOVA SIT820 Valve

1.Using the TORX

T20 bit, remove and discard the three

(3) pressure regula- tor mounting screws (A), pressure regula- tor tower (B) and the spring and diaphragm assembly (C). (Fig. 50)

2.Insure the rubber gasket (D) is properly positioned and install the new HI/LO pres- sure regulator assem- bly to the valve using the new screws (E) supplied with the kit.

A

B

C

 

OFF

N

P

L

 

I

O

TO

FC107

Fig. 50 Remove mounting screws, pressure regulator tower and spring and dia- phragm assembly.

Remove

Screws

Air Shutter

Orifice

FP1850

Fig. 52 RDV4136 burner assembly.

4. Install conversion orifices in place of orifices just removed.

5. Remove air shutters from burner pan by removing shutter retaining screw then air shutter. (Fig. 52)

6. Replace air shutter.

Natural Gas: Hole on top of mixing tube set at 1/4 open. (Fig. 53)

Propane Gas: Remove air shutter and discard.

7. Reinstall burner housing assembly and front burner tube.

10010618

31

Image 31
Contents Builder Top Vent Direct Vent Models RDV4136 Table of Contents RDV4136 Certified To Installation & Operating InstructionsAnsi Z21.88-2005 / CSA Vented Gas Fireplace Heaters Gas Equipment Venting System not Provided Requirements for the Commonwealth of MassachusettsFireplace Dimensions Mantels Mantel ChartLocating Your Fireplace Clearance to CombustiblesFinal Finishing Gas Line InstallationHearth Framing and FinishingInstallation RN/RP Models Remote ON/OFF SwitchInstallation IN/IP Models EB-1 receptacle EB-1 Electrical BoxLocation of Vent Termination General VentingGeneral Venting Information Termination Location Canadian Installations1 US Installations2Flex Vent Pipes Canadian InstallationsUSA Installations General Information on Assembling Vent PipesExample B How to Use the Vent GraphTwist Lock Pipes Example aVertical Sidewall Applications Install baffle to the deflectorZero clearance sleeve is only required for combustible walls Vertical Sidewall Installation Twist Lock PipeVertical height requirement Always install horizontal venting on a level planeBelow Grade Installations Vertical Sidewall Installation Flex Vent PipeStep Vertical Through-the-Roof Applications Vertical Through-the-Roof InstallationMin 610 mm Venting Components Glass Information Window Frame Assembly RemovalGlass Cleaning Operating InstructionsLogs Installation of Logs, Lava Rock & Ember MaterialLog Installation Log Identification ChartEmber Material Left Cross Log Right Cross Log Rear Log Front Correct pilot flame appearance Flame CharacteristicsFor Fireplaces Equipped with the SIT 820 Valve Lighting and Operating InstructionsTo Turn Off Gas To Heater Turning Off the Gas to the Appliance Lighting & Operating InstructionsFor Fireplaces equipped with AF4000 Gas Valve Lighting InstructionsAF4000 Valve TroubleshootingIgniter operation Troubleshooting AF4000 ValveAF4000 Valve Face Remove Window Frame Assembly Before Service Work Troubleshooting Honeywell VS8421SkyTech Valve Burner Orifice ConversionNova SIT820 Valve Injector Orifice Size Matrix Pilot Orifice ConversionBurner and Burner Compartment MaintenanceCleaning the Standing Pilot Control System Logs May Be HOTRDV4136 Units GFSJ5J1RP Description RDV4136 RDV4136Fuel Conversion Kits Wiring Instructions Optional AccessoriesFan Assembly Hard direct Wire Hook UpPorcelain Steel Back Remote ControlsBack-up Battery Kit Ceramic Refractory PanelsLimited Lifetime Warranty Efficiency Ratings