RDV4136 Series Direct Vent Gas Fireplace
Operating Instructions
Glass Information
Only glass approved by CFM Corporation should be used on this fireplace.
•The use of any
•Care must be taken to avoid breakage of the glass.
•Do not operate appliance with glass front removed, cracked or broken.
•Replacement glass (complete with frame window) is available through your CFM Corporation dealer and should only be installed by a licensed qualified service person.
��������
��������������
������������
������������������
�������������
��������������������
���������������
Window Frame Assembly Removal
1.Turn the fireplace OFF (including the pilot)
2.If the unit has been operating allow time for the components to cool.
3.Remove the valve access panel. (Fig. 37)
4.Rotate the two clamps securing the lower edge of the frame by pulling out on the handles. (Fig. 38)
5.Tilt the glass frame out slightly at the bottom, lift the frame up and away from the fireplace.
6.To replace the glass frame reverse the procedure.
Valve
Valve Access Panel
FP1847
Fig. 37 Remove valve access panel.
Glass
Frame
Fire- place Front
Clamps
Glass
Panel
Glass Panel
Pull
Clamp
Hook
Fig. 38 Window frame assembly removal.
Glass Cleaning
It is necessary to periodically clean the glass. During
Also initial paint curing may deposit a slight film on the glass. It is therefore recommended that the glass be cleaned two or three times with a
After the initial cleaning process the glass should be cleaned two or three times during each operating season depending on the environment in the house.
Clean the glass after the first two weeks of operation.
Do not clean glass when hot.
Do not use abrasive cleaners.
Do not strike or slam glass.
10010618 | 21 |