GE 60-960-95 installation instructions Testing Zones/Sensors, If a Wireless Sensor Does Not Test

Page 69
Table 9: Basic Touchpad Commands (Continued)

Note

While the sensor test is a valuable installation and ser- vice tool, it only tests sensor operation for the current conditions. You should per- form a sensor test after any change in environment, equipment, or programming.

Note

If you hear a long, low- pitched beep, proceed to the following section “If a Wire- less Sensor Does Not Test.”

Table 9: Basic Touchpad Commands (Continued)

 

Command

System Response

 

 

 

3

+ CODE

Arms system to AWAY

 

 

 

2

(quick arm on)

Arms system to STAY

 

 

 

3

(quick arm on)

Arms system to AWAY

 

 

2 or 3 + CODE + 4

 

or

Arm system—No Delay (no exit or entry delay)

2 or 3 + 4

 

 

 

 

5

+ 2 or 3 + CODE

 

or

Arms system silently (no arming status beeps)

5

+ 2 or 3

 

 

 

 

7

+ 1

Turns chime feature on and off

 

 

 

7

+ 2

Turns Energy Saver on and off

 

 

 

7

+ 6

Identifies alarms in memory

 

 

 

7

+ 7 + n

Turns the output on or off. (This command is only

(n = output number [1–6])

1–2 = onboard outputs

functional after output text is entered into panel

memory.)

3–6 = module outputs

 

 

 

 

8

+ CODE + 6

Partition jump

 

 

 

8

+ CODE + 2

Initiates a phone test

 

 

 

8

+ CODE + 3

Initiates a sensor test

 

 

 

8

+ installer CODE + 3

Initiates a dealer sensor test

 

 

 

8

+ CODE + 8

View Event History

 

 

 

Testing Zones/Sensors

Test sensors/zones after all programming is completed, whenever there is a change in environ- ment, equipment, or programming, and whenever a zone- or sensor-related problem occurs.

If the system does not respond as described in the following procedure, see the “Troubleshoot- ing” section.

1.Place all sensors and zones in their non-alarm state.

2.At an alphanumeric touchpad, enter the sensor test mode by pressing 8 + installer code + 3. The touchpad sounds one beep and displays SENSOR TEST. The panel starts a 15 minute timer.

3.Trip each zone/sensor one at a time. Touchpads (and interior sirens) should sound one short, high-pitched beep and the display should show the sensor name (or number) and OK.

4.Press the STATUS button when you think all zones/sensors are tested. The touchpad displays any untested sensors/zones and touchpad panics. If all sensors/zones and touchpad panics have been tested, the display shows SENSOR TEST OK.

5.Test any untested zones/sensors and touchpad panics.

6.The system stays in sensor test mode for 15 minutes. When less than 5 minutes remain, touchpads and interior sirens beep and the panel announces the remaining time over the speakers once every minute. After 15 minutes the panel disarms to OFF, automatically. If you need more time to complete the sensor test, press 8 + installer CODE + 3 while the sys- tem is still in sensor test mode. This restarts the 15 minutes of test time.

7.When all sensors/zones and touchpad panics have been tested, press 1 + installer CODE to exit sensor test mode.

If a Wireless Sensor Does Not Test

If touchpads display SENSOR FAILURE and sirens sound a long, low-pitched beep when a zone or sensor is tripped, this indicates that the wireless sensor signal strength is below acceptable limits. Distance from the receiver, the installation environment, or both, are most likely affecting the sensor signal strength.

When possible, locate wireless sensors within 100 feet of the panel. While a transmitter may have a range of 1,000 feet or more out in the open, the environment at the installation site can have a significant effect on transmitter range. Refer to the “Troubleshooting” section to resolve the problem.

Concord Ultra

64

Image 69
Contents Concord Ultra Installation Instructions6HFXULW\ 466-2061Rev CFCC Part 15 Information to the User NoticesFCC Part 15 Class B ACTA PartPlanning the Installation ContentsInstalling the System About This ManualProgramming the Panel Testing the SystemTroubleshooting UL Listed Installations Special Installation RequirementsDefault TestingRequired Setting SIA System RequirementsUL Canada Listed Installations Planning the InstallationCentral Station Reporting FunctionStandard Panel Supervised Wireless SirenSuperBus 2000 Touchpads SnapCardsSuperBus 2000 Wireless Gateway Module SuperBus 2000 Cellular Backup ModuleSuperBus 2000 8Z Input Module HIM SuperBus 2000 4-RelayOutput Module HOMPower Total System Power and Wire Length GuidelinesWire Length Determine the Panel LocationMax. Wire Length Table 2: Total System Wire Length AllowedWire Type Total System WireTable 4: Wire Requirements Mounting the PanelTable 3: Minimum Device Current Draw Identify Panel Components Installing AntennasInstalling Optional SnapCards Connecting the Panel to Earth GroundFigure 4. Installing the Antennas Figure 5. Connecting the Panel to Earth GroundConnecting Detection Devices to Panel Zone Inputs Connecting Intrusion Detection DevicesConnecting 2-WireSmoke Detectors Connecting 4-WireSmoke Detectors Connecting SpeakersTable 5 Panel Minimum Available Power 15-WattSpeakerHardwire Interior Speaker Connecting Piezo SirensInstalling Supervised Wireless Sirens Exterior SirensInterior Sirens 1.Power up the panel see “Powering Up the Panel” SuperBus 2000 Phone Interface/Voice Module Installing SuperBus 2000 ModulesSuperBus 2000 Energy Saver Module Wiring-SpeakerSuperBus 2000 Automation Module SuperBus 2000 Cellular Backup ModuleSuperBus 2000 8Z Input Module SuperBus 2000 4-RelayOutput ModuleSetting Device Address on SuperBus 2000 Devices SuperBus 2000 Wireless Gateway ModuleInstalling an RJ-31XPhone Jack Figure 21. Connecting the SuperBus to the PanelConnecting the AC Power Transformer Programming Powering Up the Panelthe Panel Entering Program ModeMoving Through Program Mode Tiers and Menus Touchpad Button Programming FunctionsTable 6: Touchpad Button Functions Figure 26. Tier 1 Program MenusProgramming Tier 1 Menu Items Installer Code Using Shortcut NumbersSecurity-GlobalDefault = Security-GlobalDefault =SIA False Alarm Reduction Access Code LockSecurity-GlobalDefault = none Security-GlobalDefault = onSecurity-Partition 1-2Default = on Security-Partition 1-2Default = onSecurity-Partition 1-2Default = on Quick Exit partition 1: 0012, partition 2:Keyswitch Style partition 1: 0016, partition 2: Keyswitch Sensor partition 1: 0015, partition 2:Security-Partition 1-2Default = none Security-Partition 1-2Default = transitionRPTS OFF/ON current setting, press Phones-CSPhone 1-3Defaults: CSPhones-CSPhone 1-3Defaults: CS RPTS OFF/ON current setting, pressphone 3: phone 3:Phones-PagerPhone 1-5Default = none Phones-CSPhone 1-3Defaults: CSPhones-PagerPhone 1-5Default = on Phones-PagerPhone 1-5Default = off0154, pager 4: 0164, pager 5: 0153, pager 4: 0163, pager 5:Latchkey Rpts pager 1: 0135, pager 2: 0145, pager 0155, pager 4: 0165, pager 5:Phones-DownloaderPhone Default = none Auto Test ResetPhone Options-GlobalDefault = on Phone Options-GlobalDefault = offPhone Options-GlobalDefault = on Cancel MessagePhone Options-GlobalDefault = on Phone Options-GlobalDefault = onRemote Access partition 1: 0211, par Call Wait CancelPhone Options-GlobalDefault = 15 sec Phone Options-GlobalDefault = nonePhone Options-Partition1 only Default = none Phone Options-Partition 1-2Default = onPhone Options-Partition 1-2Default = on Phone Options-Partition 1-2Default = offTimers Menu Phone Access Key partition 1: 0216, partition 2:RF Tx Timeout Phone Options-Partition 1-2Default = #Timers-GlobalDefault = 7 days Activity TimeoutTimers-GlobalDefault 4 sec Timers-GlobalDefault = 24 hoursTimers-Partition 1-2Default = 4 min Siren Timeout partition 1: 0313, partitionTimers-Partition 1-2Default = 4 min Timers-Partition 1-2Default = 22:00 10:00 pmTouchpad Options-GlobalDefault = none display shows HOUSE CODE nn-x current settingTouchpad Options-Partition 1-2Default = on Touchpad Options-Partition 1-2Default = onTouchpad Options-Partition 1-2Default = off Back In ServiceTouchpad Options-Partition 1-2Default = off Reporting-GlobalDefault = offBattery Restoral Low CPU BatteryTwo Trip Error Reporting-GlobalDefault = onReporting-GlobalDefault = off Reporting-GlobalDefault = offReporting-GlobalDefault = off Reporting-GlobalDefault = weeklyReporting-GlobalDefault = off Reporting-GlobalDefault =Reporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offReporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offReporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offAlarm Verify partition 1: 06108, partition 2: Freeze Alarm partition 1: 06107, partition 2:Disable Trouble Beeps Reporting-Partition 1-2Default = offSiren Options-GlobalDefault = Siren Options-GlobalDefault = offSiren Options-GlobalDefault = off Siren Options-Partition1 Default = offTable 7: How to Trip Sensors Sensors Default = noneLearn Sensors Sensors Default = none Sensors Default = noneSensors Default = none Sensor TextAudio Verification-Partition1 Default = off Access TimeoutAudio Verification-Partition1 Default = Audio Verification-Partition1 Default = offAccessory Modules Menu Access CodeAudio Verification-Partition1 Default = 02 sec This setting determines how long AVM accessPartition Assign Device IDOutput Programming Status BeepsFreeze Temp Key BeepsTemperature Cellular SystemOutput Text output 1: 10110, output 2: Acc. Modules--SnapCards-OutputText Default = noneoutput 3 10112, output Onboard Options MenuOnboard Options-InputsDefault = off Two Wire Smokerent setting Onboard Options-InputsDefault = offExiting Programming Mode Onboard Options-Output Text-Output1, 2 DefaultEntering User Programming Mode Output Text Output 1-1120,OutputTime and Date Default = 01/01/00 Time and Date Default = 00:00User Codes-Reg.User Codes-UserNNN Default = none TimeRemote Access 030nnn2 where nnn=user number Direct Bypassing 030nnn1 where nnn=user numberPartition Jump 030nnn3 where nnn=user number System Tests 030nnn4 where nnn=user numberUser Codes-PartitionMaster Code Default = none Latchkey Report 030nnn5 where nnn=user numberUser Codes-SystemMaster Code Default = Options Default = onSet Up Schedules Menu VolumeOptions Default = Options Default =Default = 00:00 Set Up Schedules 05XXY, whereAttach Schedules To Events Default = off XX=schedule 00 thru 15 and3.Press A or B until the desired light appears Energy Saver Default = 50F Attach Schedules To Events Default = offEnergy Saver Default = 90F Attach Lights To Sensors Default =Default = N/A Basic System CommandsTable 9: Basic Touchpad Commands Downloader ProgrammingTesting Zones/Sensors If a Wireless Sensor Does Not TestTable 9 Basic Touchpad Commands Continued Testing Central Station/Pager Communication Testing Phone CommunicationTable 10: Pager System Event Codes Table 11: Pager Sensor/Zone Code and NumbersTesting Light Control Testing Outputs and SirensTesting the Energy Saver Module ESM Table 12: System Alarm SoundsAdjusting Touchpad Display Contrast Table 13: Current Phone Settings Testing Cellular Backup Communication2.Check for proper panel and transformer wiring Central station/pager is not receiving reports System indicates Sensor/Touchpad nn low batterySystem doesn’t go into alarm when zone is tripped Smoke sensor beeps once every 44 seconds Cellular backup report does not occur Module doesn’t communicate with alarm.com Appendix A System Planning Worksheets Table A1: Wireless DevicesTable A3: Zone and Sensor Assignments Table A2: Hardwire DevicesTable A3: Zone and Sensor Assignments Continued Concord Ultra Table A3 Zone and Sensor Assignments ContinuedSetting reference default Table A4 System Settings Index and RecordSetting Shortcut NoException Reports phones Off Phone Test On Appendix B Reference Tables Cross-Zoning Table B1: Sensor Group Characteristics ContinuedTable B2: Item Numbers and Sensor Text Table B4: Sensor Group Event Trigger Numbers Table B3: System Event Trigger NumbersSystem Event DescriptionTable B5: Sensor Number Event Trigger Numbers Table B4 Sensor Group Event Trigger NumbersSensor Group Trigger NoSensor Table B5: Sensor Number Event Trigger NumbersTable B5: Sensor Number Event Trigger Numbers Table B6: System Feature Event Trigger NumbersTable B7: Response Characteristics Table B6: System Feature Event Trigger NumbersFeature Response CharacteristicsConcord Ultra Notes for Table B8: Response NumbersTo Enter Programming Mode: 8 + Installer or #* # * #Concord Ultra Dealer Code + 0 +#* # * # * # * # * # Concord UltraTier 2 Menus Continued Timers #* ##* # * # Concord UltraConcord Ultra Concord Ultra #* #Software Version SIA False AlarmDownloader Code Central Station ReportsDialer Abort Delay Exit DelayDisarming DownloaderConcord Ultra Optional SuperBus 2000 Module Connections