GE 60-960-95 Swinger Limit, Program Report, Opening Reports partition 1: 06100, partition 2

Page 48
Swinger Limit (06014)

Swinger Limit (06014)

Reporting-Global (Default = 1)

 

 

This setting determines the maximum number of times (1–2) a sensor or zone can go into alarm (during a single arming period) before the panel automatically bypasses that sensor or zone. This feature only applies to sensors or zones in groups 00–20, 29, 34, or 35.

When set to 1, the panel automatically bypasses a sensor or zone after it causes an alarm. When set to 2, the panel waits until a sensor or zone has caused a second alarm (during the same arming period) before bypassing it. At any setting, the automatic bypass is logged into the event buffer.

A bypassed sensor or zone will be cleared (automatically unbypassed) if the system receives no further activations from that sensor or zone over the next 48–50 hours.

Changing the arming level also clears all automatically bypassed sensors and zones and resets the Swinger Limit count on all sensors and zones.

￿To set the Swinger Limit:

1.With the display showing

SWINGER LIMIT n (current set- ting), press the desired num- ber (1–2). The display flashes the entered setting.

2.Press # and the display shows the new setting.

 

Program Report (06015)

 

 

 

Reporting-Global (Default = off)

 

 

 

 

 

When this setting is on, the panel sends a report to the cen-

￿To turn Program Report on or off:

 

tral station when someone enters or exits installer program-

1.

With the display showing PROGRAM REPORT ON/OFF (cur-

 

ming.

 

rent setting), press 1 (off) or 2 (on). The display flashes the

 

 

 

entered setting.

 

 

 

2.

Press # and the display shows the new setting.

 

 

 

 

The following sections describe the settings that appear under REPORTING—PARTITION1-2.

 

 

 

 

Opening Reports (partition 1: 06100, partition 2: 06200)

 

Reporting-Partition 1-2 (Default = off)

 

 

 

 

 

 

When this setting is on, the panel sends an opening report to the central station after disarming the system.

Note

To use this feature, the Open/Close Reports settings under the PHONES menu must be turned on for the specific CS Phone or Pager number.

￿To turn Opening Reports off or on:

1.With the display showing OPENING REPORTS OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Closing Reports (partition 1: 06101, partition 2: 06201)

Reporting-Partition 1-2 (Default = off)

 

 

When this setting is on, the panel sends a closing report to the central sta- tion after arming the system.

Note

To use this feature, the Open/Close Reports settings under the PHONES menu must be turned on for the specific CS Phone or Pager number.

￿To turn Closing Reports off or on:

1.With the display showing CLOSING REPORTS OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting.

2.Press # and the display shows the new setting.

Recent Closings (partition 1: 06102, partition 2: 06202)

 

Reporting-Partition 1-2 (Default = on)

 

 

When this setting is on, the panel sends a recent closing report to the cen-

￿To turn Recent Closings off or on:

tral station if an alarm occurs within two minutes after the exit delay time

1.

With the display showing RECENT CLOSINGS

expires. Such a report is used to identify a possible exit fault.

 

OFF/ON (current setting), press 1 (off) or 2

 

 

(on). The display flashes the entered setting.

 

2.

Press # and the display shows the new setting.

 

 

 

43

Concord Ultra

Image 48
Contents Installation Instructions Concord Ultra6HFXULW\ 466-2061Rev CNotices FCC Part 15 Information to the UserFCC Part 15 Class B ACTA PartContents Planning the InstallationInstalling the System About This ManualTesting the System Programming the PanelTroubleshooting Special Installation Requirements UL Listed InstallationsTesting DefaultRequired Setting SIA System RequirementsPlanning the Installation UL Canada Listed InstallationsCentral Station Reporting FunctionSupervised Wireless Siren Standard PanelSuperBus 2000 Touchpads SnapCardsSuperBus 2000 Cellular Backup Module SuperBus 2000 Wireless Gateway ModuleSuperBus 2000 8Z Input Module HIM SuperBus 2000 4-RelayOutput Module HOMTotal System Power and Wire Length Guidelines PowerWire Length Determine the Panel LocationTable 2: Total System Wire Length Allowed Max. Wire LengthWire Type Total System WireTable 4: Wire Requirements Mounting the PanelTable 3: Minimum Device Current Draw Installing Antennas Identify Panel ComponentsConnecting the Panel to Earth Ground Installing Optional SnapCardsFigure 4. Installing the Antennas Figure 5. Connecting the Panel to Earth GroundConnecting Detection Devices to Panel Zone Inputs Connecting Intrusion Detection DevicesConnecting 2-WireSmoke Detectors Connecting Speakers Connecting 4-WireSmoke DetectorsTable 5 Panel Minimum Available Power 15-WattSpeakerConnecting Piezo Sirens Hardwire Interior SpeakerInstalling Supervised Wireless Sirens Exterior SirensInterior Sirens 1.Power up the panel see “Powering Up the Panel” Installing SuperBus 2000 Modules SuperBus 2000 Phone Interface/Voice ModuleWiring-Speaker SuperBus 2000 Energy Saver ModuleSuperBus 2000 Cellular Backup Module SuperBus 2000 Automation ModuleSuperBus 2000 8Z Input Module SuperBus 2000 4-RelayOutput ModuleSuperBus 2000 Wireless Gateway Module Setting Device Address on SuperBus 2000 DevicesInstalling an RJ-31XPhone Jack Figure 21. Connecting the SuperBus to the PanelConnecting the AC Power Transformer Powering Up the Panel Programmingthe Panel Entering Program ModeTouchpad Button Programming Functions Moving Through Program Mode Tiers and MenusTable 6: Touchpad Button Functions Figure 26. Tier 1 Program MenusProgramming Tier 1 Menu Items Using Shortcut Numbers Installer CodeSecurity-GlobalDefault = Security-GlobalDefault =Access Code Lock SIA False Alarm ReductionSecurity-GlobalDefault = none Security-GlobalDefault = onSecurity-Partition 1-2Default = on Security-Partition 1-2Default = onSecurity-Partition 1-2Default = on Quick Exit partition 1: 0012, partition 2:Keyswitch Sensor partition 1: 0015, partition 2: Keyswitch Style partition 1: 0016, partition 2:Security-Partition 1-2Default = none Security-Partition 1-2Default = transitionPhones-CSPhone 1-3Defaults: CS RPTS OFF/ON current setting, pressPhones-CSPhone 1-3Defaults: CS RPTS OFF/ON current setting, pressphone 3: phone 3:Phones-CSPhone 1-3Defaults: CS Phones-PagerPhone 1-5Default = nonePhones-PagerPhone 1-5Default = on Phones-PagerPhone 1-5Default = off0153, pager 4: 0163, pager 5: 0154, pager 4: 0164, pager 5:Latchkey Rpts pager 1: 0135, pager 2: 0145, pager 0155, pager 4: 0165, pager 5:Auto Test Reset Phones-DownloaderPhone Default = nonePhone Options-GlobalDefault = on Phone Options-GlobalDefault = offCancel Message Phone Options-GlobalDefault = onPhone Options-GlobalDefault = on Phone Options-GlobalDefault = onCall Wait Cancel Remote Access partition 1: 0211, parPhone Options-GlobalDefault = 15 sec Phone Options-GlobalDefault = nonePhone Options-Partition 1-2Default = on Phone Options-Partition1 only Default = nonePhone Options-Partition 1-2Default = on Phone Options-Partition 1-2Default = offPhone Access Key partition 1: 0216, partition 2: Timers MenuRF Tx Timeout Phone Options-Partition 1-2Default = #Activity Timeout Timers-GlobalDefault = 7 daysTimers-GlobalDefault 4 sec Timers-GlobalDefault = 24 hoursSiren Timeout partition 1: 0313, partition Timers-Partition 1-2Default = 4 minTimers-Partition 1-2Default = 4 min Timers-Partition 1-2Default = 22:00 10:00 pmdisplay shows HOUSE CODE nn-x current setting Touchpad Options-GlobalDefault = noneTouchpad Options-Partition 1-2Default = on Touchpad Options-Partition 1-2Default = onBack In Service Touchpad Options-Partition 1-2Default = offTouchpad Options-Partition 1-2Default = off Reporting-GlobalDefault = offLow CPU Battery Battery RestoralTwo Trip Error Reporting-GlobalDefault = onReporting-GlobalDefault = off Reporting-GlobalDefault = offReporting-GlobalDefault = off Reporting-GlobalDefault = weeklyReporting-GlobalDefault = Reporting-GlobalDefault = offReporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offReporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offReporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offFreeze Alarm partition 1: 06107, partition 2: Alarm Verify partition 1: 06108, partition 2:Disable Trouble Beeps Reporting-Partition 1-2Default = offSiren Options-GlobalDefault = off Siren Options-GlobalDefault =Siren Options-GlobalDefault = off Siren Options-Partition1 Default = offTable 7: How to Trip Sensors Sensors Default = noneLearn Sensors Sensors Default = none Sensors Default = noneSensors Default = none Sensor TextAccess Timeout Audio Verification-Partition1 Default = offAudio Verification-Partition1 Default = Audio Verification-Partition1 Default = offAccess Code Accessory Modules MenuAudio Verification-Partition1 Default = 02 sec This setting determines how long AVM accessDevice ID Partition AssignOutput Programming Status BeepsKey Beeps Freeze TempTemperature Cellular SystemAcc. Modules--SnapCards-OutputText Default = none Output Text output 1: 10110, output 2:output 3 10112, output Onboard Options MenuTwo Wire Smoke Onboard Options-InputsDefault = offrent setting Onboard Options-InputsDefault = offOnboard Options-Output Text-Output1, 2 Default Exiting Programming ModeEntering User Programming Mode Output Text Output 1-1120,OutputTime and Date Default = 00:00 Time and Date Default = 01/01/00User Codes-Reg.User Codes-UserNNN Default = none TimeDirect Bypassing 030nnn1 where nnn=user number Remote Access 030nnn2 where nnn=user numberPartition Jump 030nnn3 where nnn=user number System Tests 030nnn4 where nnn=user numberLatchkey Report 030nnn5 where nnn=user number User Codes-PartitionMaster Code Default = noneUser Codes-SystemMaster Code Default = Options Default = onVolume Set Up Schedules MenuOptions Default = Options Default =Set Up Schedules 05XXY, where Default = 00:00Attach Schedules To Events Default = off XX=schedule 00 thru 15 and3.Press A or B until the desired light appears Attach Schedules To Events Default = off Energy Saver Default = 50FEnergy Saver Default = 90F Attach Lights To Sensors Default =Basic System Commands Default = N/ATable 9: Basic Touchpad Commands Downloader ProgrammingTesting Zones/Sensors If a Wireless Sensor Does Not TestTable 9 Basic Touchpad Commands Continued Testing Phone Communication Testing Central Station/Pager CommunicationTable 10: Pager System Event Codes Table 11: Pager Sensor/Zone Code and NumbersTesting Outputs and Sirens Testing Light ControlTesting the Energy Saver Module ESM Table 12: System Alarm SoundsAdjusting Touchpad Display Contrast Testing Cellular Backup Communication Table 13: Current Phone Settings2.Check for proper panel and transformer wiring System indicates Sensor/Touchpad nn low battery Central station/pager is not receiving reportsSystem doesn’t go into alarm when zone is tripped Smoke sensor beeps once every 44 seconds Cellular backup report does not occur Module doesn’t communicate with alarm.com Table A1: Wireless Devices Appendix A System Planning WorksheetsTable A2: Hardwire Devices Table A3: Zone and Sensor AssignmentsTable A3: Zone and Sensor Assignments Continued Table A3 Zone and Sensor Assignments Continued Concord UltraTable A4 System Settings Index and Record Setting reference defaultSetting Shortcut NoException Reports phones Off Phone Test On Appendix B Reference Tables Table B1: Sensor Group Characteristics Continued Cross-ZoningTable B2: Item Numbers and Sensor Text Table B3: System Event Trigger Numbers Table B4: Sensor Group Event Trigger NumbersSystem Event DescriptionTable B4 Sensor Group Event Trigger Numbers Table B5: Sensor Number Event Trigger NumbersSensor Group Trigger NoTable B5: Sensor Number Event Trigger Numbers SensorTable B6: System Feature Event Trigger Numbers Table B5: Sensor Number Event Trigger NumbersTable B6: System Feature Event Trigger Numbers Table B7: Response CharacteristicsFeature Response CharacteristicsNotes for Table B8: Response Numbers Concord Ultra#* # * # To Enter Programming Mode: 8 + Installer orConcord Ultra Dealer Code + 0 +#* # * # * # * # * # Concord UltraTier 2 Menus Continued #* # Timers#* # * # Concord UltraConcord Ultra #* # Concord UltraSIA False Alarm Software VersionDownloader Code Central Station ReportsExit Delay Dialer Abort DelayDisarming DownloaderConcord Ultra Optional SuperBus 2000 Module Connections