Programming Tier 2 Menu Items

Clear Memory (System Programming)

Clearing memory deletes all existing programming information (except the Dealer Code).

Note

Clearing the memory will erase onboard hardwire zone factory programming.

￿To Clear Panel Memory:

1.With the system in program mode, press A or B until the display shows CLEAR MEMORY.

2.Press # and the display shows ENTER CODE TO CLEAR MEMORY.

3.Enter the 4-digit installer or dealer code (if programmed) + #. After about five seconds, the system restarts and the panel scans the bus to learn all bus devices.

If the system doesn’t respond as described, repeat step 3.

Programming Tier 2 Menu Items

This section guides you through programming tier 2 menu items as they appear in sequence. Figure 27 shows the menus available on tier 2.

Each menu on tier 2 represents a group of settings related to the menu name. Some tier 2 menus break down into settings that affect the whole system (global) or a specific partition.

Using Shortcut Numbers

To go directly to a setting in tier 2, you can enter the shortcut number for that setting. Shortcut numbers in this manual appear in parenthesis ( ), next to the setting name. The menu appears to the right. For example this heading shows the Downloader Code shortcut to be 0000.

Downloader Code (0000)

System Programming

Shortcut numbers can be used from any setting location within tier 2.

￿To advance to tier 2 program menus:

￿With the system in program mode and the display showing SYSTEM PROGRAMMING, press # once. The display should show SECURITY.

Security Menu

The SECURITY menu lets you choose whether security settings affect the whole system (global) or a specific partition.

￿To access global or partition security menu items:

1.With the display showing SECURITY, press #. The display should show GLOBAL.

2.Press # again to advance to global settings, or press A or B to display PARTITION n, then press

# to advance to selected partition 1 or 2 settings.

The following describes how to program the security settings that appear under GLOBAL.

Downloader Code (0000)

Security-Global (Default = 12345)

 

 

The 5-digit downloader code is used in conjunction with downloader pro- gramming. The down-loader operator must have the panel account number and downloader code in order to perform any programming.

Note

The Downloader Code cannot be deleted from panel memory. To change the Downloader Code to its default setting, enter 12345 in the procedure to the right. The Downloader Code will be reset to defaults during a Memory Clear only if the Dealer Code is not set OR if the Dealer Code is used to initiate the Memory Clear.

To program a Downloader Code:

1.With the display showing DOWNLOADER CODE nnnnn (current code), enter the desired 5-digit code, + ƒ. The display flashes the entered code.

2.Press ƒ and the display shows the new code.

Installer Code (0001)

Security-Global (Default = 4321)

 

 

The 4-digit installer code is used for entering program mode and changing system settings. If a dealer code is programmed, only those settings not associated with phone numbers can be changed.

Note

The Installer Code cannot be deleted or cleared from panel memory. To change the Installer Code to its default setting, enter 4321.

To program a Downloader Code:

￿To program an Installer Code:

1.With the display showing INSTALLER CODE nnnn (current code), enter the desired 4-digit code. The display flashes the entered code.

2.Press # and the display shows the new code.

Concord Ultra

24

Image 29
Contents Concord Ultra Installation Instructions6HFXULW\ 466-2061Rev CFCC Part 15 Information to the User NoticesFCC Part 15 Class B ACTA PartPlanning the Installation ContentsInstalling the System About This ManualProgramming the Panel Testing the SystemTroubleshooting UL Listed Installations Special Installation RequirementsDefault TestingRequired Setting SIA System RequirementsUL Canada Listed Installations Planning the InstallationCentral Station Reporting FunctionStandard Panel Supervised Wireless SirenSuperBus 2000 Touchpads SnapCardsSuperBus 2000 Wireless Gateway Module SuperBus 2000 Cellular Backup ModuleSuperBus 2000 8Z Input Module HIM SuperBus 2000 4-RelayOutput Module HOMPower Total System Power and Wire Length GuidelinesWire Length Determine the Panel LocationMax. Wire Length Table 2: Total System Wire Length AllowedWire Type Total System WireTable 3: Minimum Device Current Draw Table 4: Wire RequirementsMounting the Panel Identify Panel Components Installing AntennasInstalling Optional SnapCards Connecting the Panel to Earth GroundFigure 4. Installing the Antennas Figure 5. Connecting the Panel to Earth GroundConnecting 2-WireSmoke Detectors Connecting Detection Devices to Panel Zone InputsConnecting Intrusion Detection Devices Connecting 4-WireSmoke Detectors Connecting SpeakersTable 5 Panel Minimum Available Power 15-WattSpeakerHardwire Interior Speaker Connecting Piezo SirensInterior Sirens Installing Supervised Wireless SirensExterior Sirens 1.Power up the panel see “Powering Up the Panel” SuperBus 2000 Phone Interface/Voice Module Installing SuperBus 2000 ModulesSuperBus 2000 Energy Saver Module Wiring-SpeakerSuperBus 2000 Automation Module SuperBus 2000 Cellular Backup ModuleSuperBus 2000 8Z Input Module SuperBus 2000 4-RelayOutput ModuleSetting Device Address on SuperBus 2000 Devices SuperBus 2000 Wireless Gateway ModuleInstalling an RJ-31XPhone Jack Figure 21. Connecting the SuperBus to the PanelConnecting the AC Power Transformer Programming Powering Up the Panelthe Panel Entering Program ModeMoving Through Program Mode Tiers and Menus Touchpad Button Programming FunctionsTable 6: Touchpad Button Functions Figure 26. Tier 1 Program MenusProgramming Tier 1 Menu Items Installer Code Using Shortcut NumbersSecurity-GlobalDefault = Security-GlobalDefault =SIA False Alarm Reduction Access Code LockSecurity-GlobalDefault = none Security-GlobalDefault = onSecurity-Partition 1-2Default = on Security-Partition 1-2Default = onSecurity-Partition 1-2Default = on Quick Exit partition 1: 0012, partition 2:Keyswitch Style partition 1: 0016, partition 2: Keyswitch Sensor partition 1: 0015, partition 2:Security-Partition 1-2Default = none Security-Partition 1-2Default = transitionRPTS OFF/ON current setting, press Phones-CSPhone 1-3Defaults: CSPhones-CSPhone 1-3Defaults: CS RPTS OFF/ON current setting, pressphone 3: phone 3:Phones-PagerPhone 1-5Default = none Phones-CSPhone 1-3Defaults: CSPhones-PagerPhone 1-5Default = on Phones-PagerPhone 1-5Default = off0154, pager 4: 0164, pager 5: 0153, pager 4: 0163, pager 5:Latchkey Rpts pager 1: 0135, pager 2: 0145, pager 0155, pager 4: 0165, pager 5:Phones-DownloaderPhone Default = none Auto Test ResetPhone Options-GlobalDefault = on Phone Options-GlobalDefault = offPhone Options-GlobalDefault = on Cancel MessagePhone Options-GlobalDefault = on Phone Options-GlobalDefault = onRemote Access partition 1: 0211, par Call Wait CancelPhone Options-GlobalDefault = 15 sec Phone Options-GlobalDefault = nonePhone Options-Partition1 only Default = none Phone Options-Partition 1-2Default = onPhone Options-Partition 1-2Default = on Phone Options-Partition 1-2Default = offTimers Menu Phone Access Key partition 1: 0216, partition 2:RF Tx Timeout Phone Options-Partition 1-2Default = #Timers-GlobalDefault = 7 days Activity TimeoutTimers-GlobalDefault 4 sec Timers-GlobalDefault = 24 hoursTimers-Partition 1-2Default = 4 min Siren Timeout partition 1: 0313, partitionTimers-Partition 1-2Default = 4 min Timers-Partition 1-2Default = 22:00 10:00 pmTouchpad Options-GlobalDefault = none display shows HOUSE CODE nn-x current settingTouchpad Options-Partition 1-2Default = on Touchpad Options-Partition 1-2Default = onTouchpad Options-Partition 1-2Default = off Back In ServiceTouchpad Options-Partition 1-2Default = off Reporting-GlobalDefault = offBattery Restoral Low CPU BatteryTwo Trip Error Reporting-GlobalDefault = onReporting-GlobalDefault = off Reporting-GlobalDefault = offReporting-GlobalDefault = off Reporting-GlobalDefault = weeklyReporting-GlobalDefault = off Reporting-GlobalDefault =Reporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offReporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offReporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offAlarm Verify partition 1: 06108, partition 2: Freeze Alarm partition 1: 06107, partition 2:Disable Trouble Beeps Reporting-Partition 1-2Default = offSiren Options-GlobalDefault = Siren Options-GlobalDefault = offSiren Options-GlobalDefault = off Siren Options-Partition1 Default = offLearn Sensors Table 7: How to Trip SensorsSensors Default = none Sensors Default = none Sensors Default = noneSensors Default = none Sensor TextAudio Verification-Partition1 Default = off Access TimeoutAudio Verification-Partition1 Default = Audio Verification-Partition1 Default = offAccessory Modules Menu Access CodeAudio Verification-Partition1 Default = 02 sec This setting determines how long AVM accessPartition Assign Device IDOutput Programming Status BeepsFreeze Temp Key BeepsTemperature Cellular SystemOutput Text output 1: 10110, output 2: Acc. Modules--SnapCards-OutputText Default = noneoutput 3 10112, output Onboard Options MenuOnboard Options-InputsDefault = off Two Wire Smokerent setting Onboard Options-InputsDefault = offExiting Programming Mode Onboard Options-Output Text-Output1, 2 DefaultEntering User Programming Mode Output Text Output 1-1120,OutputTime and Date Default = 01/01/00 Time and Date Default = 00:00User Codes-Reg.User Codes-UserNNN Default = none TimeRemote Access 030nnn2 where nnn=user number Direct Bypassing 030nnn1 where nnn=user numberPartition Jump 030nnn3 where nnn=user number System Tests 030nnn4 where nnn=user numberUser Codes-PartitionMaster Code Default = none Latchkey Report 030nnn5 where nnn=user numberUser Codes-SystemMaster Code Default = Options Default = onSet Up Schedules Menu VolumeOptions Default = Options Default =Default = 00:00 Set Up Schedules 05XXY, whereAttach Schedules To Events Default = off XX=schedule 00 thru 15 and3.Press A or B until the desired light appears Energy Saver Default = 50F Attach Schedules To Events Default = offEnergy Saver Default = 90F Attach Lights To Sensors Default =Default = N/A Basic System CommandsTable 9: Basic Touchpad Commands Downloader ProgrammingTable 9 Basic Touchpad Commands Continued Testing Zones/SensorsIf a Wireless Sensor Does Not Test Testing Central Station/Pager Communication Testing Phone CommunicationTable 10: Pager System Event Codes Table 11: Pager Sensor/Zone Code and NumbersTesting Light Control Testing Outputs and SirensTesting the Energy Saver Module ESM Table 12: System Alarm SoundsAdjusting Touchpad Display Contrast Table 13: Current Phone Settings Testing Cellular Backup Communication2.Check for proper panel and transformer wiring Central station/pager is not receiving reports System indicates Sensor/Touchpad nn low batterySystem doesn’t go into alarm when zone is tripped Smoke sensor beeps once every 44 seconds Cellular backup report does not occur Module doesn’t communicate with alarm.com Appendix A System Planning Worksheets Table A1: Wireless DevicesTable A3: Zone and Sensor Assignments Table A2: Hardwire DevicesTable A3: Zone and Sensor Assignments Continued Concord Ultra Table A3 Zone and Sensor Assignments ContinuedSetting reference default Table A4 System Settings Index and RecordSetting Shortcut NoException Reports phones Off Phone Test On Appendix B Reference Tables Cross-Zoning Table B1: Sensor Group Characteristics ContinuedTable B2: Item Numbers and Sensor Text Table B4: Sensor Group Event Trigger Numbers Table B3: System Event Trigger NumbersSystem Event DescriptionTable B5: Sensor Number Event Trigger Numbers Table B4 Sensor Group Event Trigger NumbersSensor Group Trigger NoSensor Table B5: Sensor Number Event Trigger NumbersTable B5: Sensor Number Event Trigger Numbers Table B6: System Feature Event Trigger NumbersTable B7: Response Characteristics Table B6: System Feature Event Trigger NumbersFeature Response CharacteristicsConcord Ultra Notes for Table B8: Response NumbersTo Enter Programming Mode: 8 + Installer or #* # * #Concord Ultra Dealer Code + 0 +Tier 2 Menus Continued #* # * # * # * # * #Concord Ultra Timers #* ##* # * # Concord UltraConcord Ultra Concord Ultra #* #Software Version SIA False AlarmDownloader Code Central Station ReportsDialer Abort Delay Exit DelayDisarming DownloaderConcord Ultra Optional SuperBus 2000 Module Connections