GE 60-960-95 installation instructions Key Beeps, Freeze Temp, Temperature, Cellular System

Page 57
Key Beeps

 

Key Beeps

Acc. Modules--Bus Device-Unit ID-Keypad Options (Default = on)

 

 

 

 

 

This setting determines whether or not selected

￿To turn Key Beeps on or off:

 

touchpads beep when their buttons are pressed.

1.

With the display showing the desired touchpad, press # then A or B

 

This feature is usually turned off for a touchpad

 

until the display shows KEYPAD OPTIONS. Next, press # then A or B

 

that is located in or near bedrooms, to avoid dis-

 

until the display shows KEY BEEPS OFF/ON (current setting).

 

turbing sleeping persons.

2.

Press 1 (off) or 2 (on) to select the desired setting. The display flashes

 

 

 

 

the entered selection.

 

 

 

3.

Press # and the display shows the new setting.

 

 

 

 

 

 

 

 

 

Freeze Temp

Acc. Modules--Bus Device-Unit ID-Energy Options (Default = 42°F)

 

 

 

 

 

This setting determines the temperature point that

￿To change the Freeze Temp setting:

 

the Energy Saver Module detects a potential

1.

With the display showing the desired bus device press #, then A or B

 

freeze (heating failure) condition. The adjustable

 

until the display shows ENERGY OPTIONS. Next, press # then A or B

 

range is from 40° to 90°F.

 

until the display shows FREEZE TEMP nn DEGREES (current setting).

 

 

 

2.

Enter the desired freeze temperature (40°–90° F). The display flashes

 

 

 

 

the entered selection.

 

 

 

3.

Press # and the display shows the new setting.

 

 

 

 

 

 

 

 

Temperature

 

Acc. Modules--Bus Device-Unit ID-Energy Options (Default = none)

 

 

 

 

 

This setting lets you adjust the Energy Saver Module (ESM) room temperature setting to match the premises thermostat. The adjustable range is from 40°–90°F.

Note

To ensure accuracy, wait at least 15 minutes before setting the ESM temperature to allow the ESM to warm or cool to actual room temperature.

￿To change the ESM Temperature setting:

1.With the display showing the desired bus device press #, then A or B until the display shows ENERGY OPTIONS. Next, press # and then A or B until the display shows TEMPERATURE nn DEGREES (current setting).

2.Enter the desired temperature (40°–90° F). The display flashes the entered selection.

3.Press # and the display shows the new setting.

Cellular System

Acc. Modules--Bus Device-Unit ID-Cellular Options (Default = B)

 

 

This setting determines the cellular transmis- sion system (A or B) used for cellular commu- nication. This information is provided by the cellular provider based on installation ZIP code.

￿To set the Cellular System:

1.With the display showing the desired bus device press 1, (B) or 2 (A). The display flashes the entered selection.

2.Press # and the display shows the new setting.

The following describes how to program the settings that appear under SNAPCARDS.

Concord Ultra

52

Image 57
Contents Concord Ultra Installation Instructions6HFXULW\ 466-2061Rev CFCC Part 15 Information to the User NoticesFCC Part 15 Class B ACTA PartPlanning the Installation ContentsInstalling the System About This ManualProgramming the Panel Testing the SystemTroubleshooting UL Listed Installations Special Installation RequirementsDefault TestingRequired Setting SIA System RequirementsUL Canada Listed Installations Planning the InstallationCentral Station Reporting FunctionStandard Panel Supervised Wireless SirenSuperBus 2000 Touchpads SnapCardsSuperBus 2000 Wireless Gateway Module SuperBus 2000 Cellular Backup ModuleSuperBus 2000 8Z Input Module HIM SuperBus 2000 4-RelayOutput Module HOMPower Total System Power and Wire Length GuidelinesWire Length Determine the Panel LocationMax. Wire Length Table 2: Total System Wire Length AllowedWire Type Total System WireTable 4: Wire Requirements Mounting the PanelTable 3: Minimum Device Current Draw Identify Panel Components Installing AntennasInstalling Optional SnapCards Connecting the Panel to Earth GroundFigure 4. Installing the Antennas Figure 5. Connecting the Panel to Earth GroundConnecting Detection Devices to Panel Zone Inputs Connecting Intrusion Detection DevicesConnecting 2-WireSmoke Detectors Connecting 4-WireSmoke Detectors Connecting SpeakersTable 5 Panel Minimum Available Power 15-WattSpeakerHardwire Interior Speaker Connecting Piezo SirensInstalling Supervised Wireless Sirens Exterior SirensInterior Sirens 1.Power up the panel see “Powering Up the Panel” SuperBus 2000 Phone Interface/Voice Module Installing SuperBus 2000 ModulesSuperBus 2000 Energy Saver Module Wiring-SpeakerSuperBus 2000 Automation Module SuperBus 2000 Cellular Backup ModuleSuperBus 2000 8Z Input Module SuperBus 2000 4-RelayOutput ModuleSetting Device Address on SuperBus 2000 Devices SuperBus 2000 Wireless Gateway ModuleInstalling an RJ-31XPhone Jack Figure 21. Connecting the SuperBus to the PanelConnecting the AC Power Transformer Programming Powering Up the Panelthe Panel Entering Program ModeMoving Through Program Mode Tiers and Menus Touchpad Button Programming FunctionsTable 6: Touchpad Button Functions Figure 26. Tier 1 Program MenusProgramming Tier 1 Menu Items Installer Code Using Shortcut NumbersSecurity-GlobalDefault = Security-GlobalDefault =SIA False Alarm Reduction Access Code LockSecurity-GlobalDefault = none Security-GlobalDefault = onSecurity-Partition 1-2Default = on Security-Partition 1-2Default = onSecurity-Partition 1-2Default = on Quick Exit partition 1: 0012, partition 2:Keyswitch Style partition 1: 0016, partition 2: Keyswitch Sensor partition 1: 0015, partition 2:Security-Partition 1-2Default = none Security-Partition 1-2Default = transitionRPTS OFF/ON current setting, press Phones-CSPhone 1-3Defaults: CSPhones-CSPhone 1-3Defaults: CS RPTS OFF/ON current setting, pressphone 3: phone 3:Phones-PagerPhone 1-5Default = none Phones-CSPhone 1-3Defaults: CSPhones-PagerPhone 1-5Default = on Phones-PagerPhone 1-5Default = off0154, pager 4: 0164, pager 5: 0153, pager 4: 0163, pager 5:Latchkey Rpts pager 1: 0135, pager 2: 0145, pager 0155, pager 4: 0165, pager 5:Phones-DownloaderPhone Default = none Auto Test ResetPhone Options-GlobalDefault = on Phone Options-GlobalDefault = offPhone Options-GlobalDefault = on Cancel MessagePhone Options-GlobalDefault = on Phone Options-GlobalDefault = onRemote Access partition 1: 0211, par Call Wait CancelPhone Options-GlobalDefault = 15 sec Phone Options-GlobalDefault = nonePhone Options-Partition1 only Default = none Phone Options-Partition 1-2Default = onPhone Options-Partition 1-2Default = on Phone Options-Partition 1-2Default = offTimers Menu Phone Access Key partition 1: 0216, partition 2:RF Tx Timeout Phone Options-Partition 1-2Default = #Timers-GlobalDefault = 7 days Activity TimeoutTimers-GlobalDefault 4 sec Timers-GlobalDefault = 24 hoursTimers-Partition 1-2Default = 4 min Siren Timeout partition 1: 0313, partitionTimers-Partition 1-2Default = 4 min Timers-Partition 1-2Default = 22:00 10:00 pmTouchpad Options-GlobalDefault = none display shows HOUSE CODE nn-x current settingTouchpad Options-Partition 1-2Default = on Touchpad Options-Partition 1-2Default = onTouchpad Options-Partition 1-2Default = off Back In ServiceTouchpad Options-Partition 1-2Default = off Reporting-GlobalDefault = offBattery Restoral Low CPU BatteryTwo Trip Error Reporting-GlobalDefault = onReporting-GlobalDefault = off Reporting-GlobalDefault = offReporting-GlobalDefault = off Reporting-GlobalDefault = weeklyReporting-GlobalDefault = off Reporting-GlobalDefault =Reporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offReporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offReporting-Partition 1-2Default = off Reporting-Partition 1-2Default = offAlarm Verify partition 1: 06108, partition 2: Freeze Alarm partition 1: 06107, partition 2:Disable Trouble Beeps Reporting-Partition 1-2Default = offSiren Options-GlobalDefault = Siren Options-GlobalDefault = offSiren Options-GlobalDefault = off Siren Options-Partition1 Default = offTable 7: How to Trip Sensors Sensors Default = noneLearn Sensors Sensors Default = none Sensors Default = noneSensors Default = none Sensor Text Audio Verification-Partition1 Default = off Access Timeout Audio Verification-Partition1 Default = Audio Verification-Partition1 Default = offAccessory Modules Menu Access CodeAudio Verification-Partition1 Default = 02 sec This setting determines how long AVM accessPartition Assign Device IDOutput Programming Status BeepsFreeze Temp Key BeepsTemperature Cellular SystemOutput Text output 1: 10110, output 2: Acc. Modules--SnapCards-OutputText Default = noneoutput 3 10112, output Onboard Options MenuOnboard Options-InputsDefault = off Two Wire Smokerent setting Onboard Options-InputsDefault = offExiting Programming Mode Onboard Options-Output Text-Output1, 2 DefaultEntering User Programming Mode Output Text Output 1-1120,OutputTime and Date Default = 01/01/00 Time and Date Default = 00:00User Codes-Reg.User Codes-UserNNN Default = none TimeRemote Access 030nnn2 where nnn=user number Direct Bypassing 030nnn1 where nnn=user numberPartition Jump 030nnn3 where nnn=user number System Tests 030nnn4 where nnn=user numberUser Codes-PartitionMaster Code Default = none Latchkey Report 030nnn5 where nnn=user numberUser Codes-SystemMaster Code Default = Options Default = onSet Up Schedules Menu VolumeOptions Default = Options Default =Default = 00:00 Set Up Schedules 05XXY, whereAttach Schedules To Events Default = off XX=schedule 00 thru 15 and3.Press A or B until the desired light appears Energy Saver Default = 50F Attach Schedules To Events Default = offEnergy Saver Default = 90F Attach Lights To Sensors Default =Default = N/A Basic System CommandsTable 9: Basic Touchpad Commands Downloader ProgrammingTesting Zones/Sensors If a Wireless Sensor Does Not TestTable 9 Basic Touchpad Commands Continued Testing Central Station/Pager Communication Testing Phone CommunicationTable 10: Pager System Event Codes Table 11: Pager Sensor/Zone Code and NumbersTesting Light Control Testing Outputs and SirensTesting the Energy Saver Module ESM Table 12: System Alarm SoundsAdjusting Touchpad Display Contrast Table 13: Current Phone Settings Testing Cellular Backup Communication2.Check for proper panel and transformer wiring Central station/pager is not receiving reports System indicates Sensor/Touchpad nn low batterySystem doesn’t go into alarm when zone is tripped Smoke sensor beeps once every 44 seconds Cellular backup report does not occur Module doesn’t communicate with alarm.com Appendix A System Planning Worksheets Table A1: Wireless DevicesTable A3: Zone and Sensor Assignments Table A2: Hardwire DevicesTable A3: Zone and Sensor Assignments Continued Concord Ultra Table A3 Zone and Sensor Assignments ContinuedSetting reference default Table A4 System Settings Index and RecordSetting Shortcut NoException Reports phones Off Phone Test On Appendix B Reference Tables Cross-Zoning Table B1: Sensor Group Characteristics ContinuedTable B2: Item Numbers and Sensor Text Table B4: Sensor Group Event Trigger Numbers Table B3: System Event Trigger NumbersSystem Event DescriptionTable B5: Sensor Number Event Trigger Numbers Table B4 Sensor Group Event Trigger NumbersSensor Group Trigger NoSensor Table B5: Sensor Number Event Trigger NumbersTable B5: Sensor Number Event Trigger Numbers Table B6: System Feature Event Trigger NumbersTable B7: Response Characteristics Table B6: System Feature Event Trigger NumbersFeature Response CharacteristicsConcord Ultra Notes for Table B8: Response NumbersTo Enter Programming Mode: 8 + Installer or #* # * #Concord Ultra Dealer Code + 0 +#* # * # * # * # * # Concord UltraTier 2 Menus Continued Timers #* ##* # * # Concord UltraConcord Ultra Concord Ultra #* #Software Version SIA False AlarmDownloader Code Central Station ReportsDialer Abort Delay Exit DelayDisarming DownloaderConcord Ultra Optional SuperBus 2000 Module Connections