GE 60-883-95R Option 21 Call Button Enable, Option 22 Downloader Enable, Option 23 300 Baud

Page 19

Option 21: Call Button Enable

 

Range = 1, 2, Off (Default = 1)

Determines how the panel Call button activates alarms. When set to 1, a sin-

¾ To program Call Button Enable:

gle press of the Call button will activate an alarm. When set to 2, pressing

1.

Press Add.

the Call button twice or pressing and holding the Call button will activate an

2.

Press Option #.

alarm. Delete will disable the Call button.

Note

3.

Press 2, then 1.

When this option is set to 2 and Option 1 is on, the panel will prompt the user to

4.

Enter a Call Button Enable setting using the

“Press again for emergency call or press Status to cancel.”

 

numbered buttons.

 

 

5.

Press Done.

 

 

 

Option 22: Downloader Enable

 

Range = On/Off (Default = On)

 

 

Determines whether the panel can be accessed using CareGard Configurator

¾ To Add or Delete Downloader Enable:

(on), or not (off).

1.

Press Add or Delete.

Note

2.

Press Option #.

Downloader is not currently supported.

3.

Press 2, then 2 again.

 

 

 

 

4.

Press Done.

 

 

 

Option 23: 300 Baud

 

Range = On/Off (Default = On)

 

 

Determines whether the baud rate used by the panel for central station or

¾ To Add or Delete 300 Baud:

modem communications is 300 bps (on) or 110 bps (off).

1.

Press Add or Delete.

 

 

2.

Press Option #.

 

 

3.

Press 2, then 3.

 

 

4.

Press Done.

 

 

 

Option 24: Audio Verification

 

Range = On/Off (Default = On)

 

 

Determines whether the system can perform 2-way voice audio sessions

¾ To Add or Delete Audio Verification:

with a central station operator (on), or not (off).

1.

Press Add or Delete.

Note

2.

Press Option #.

If this option is off, Option 26: AVM Mode will not work.

3.

Press 2, then 4.

 

 

 

 

4.

Press Done.

 

 

 

Option 25: Trouble Beeps

 

Range = On/Off (Default = Off)

 

 

Determines whether the panel sounds six beeps every minute when a trouble

¾ To Add or Delete Trouble Beeps:

condition occurs (on) or not (off) The following conditions cause trouble

1.

Press Add or Delete.

beeps:

2.

Press Option #.

AC Power Failure

3.

Press 2, then 5.

Low CPU Battery

4.

Press Done.

Sensor Failure (supervisory)

 

 

• Sensor Trouble (low battery)

 

 

Fail to communicate

 

 

RF Jam

 

 

Trouble beeps can be silenced by pressing the Status button. Trouble beeps

 

 

resume 4 hours later if the trouble condition is not cleared.

 

 

 

 

 

Option 26: AVM Mode

 

Range = On/Off (Default = Off)

 

 

Determines whether the panel hangs up and waits for a call-back from the

¾ To Add or Delete AVM Mode:

central station operator before starting an audio session (on) or stays on line

1.

Press Add or Delete.

with the central station for an instant audio session (off).

2.

Press Option #.

Note

3.

Press 2, then 6.

Option 24: Audio Verification must be on for this feature to work.

Option 26 affects the primary phone number only.

4.

Press Done.

 

 

 

 

Programming Options

14

Image 19
Contents CareGard FCC Part 15 Information to the User GE InterlogixContents Medication Reminders Activity CheckAdding/Replacing Sensors Troubleshooting Sensor Testing Phone Communication TestingDeleting Sensors System Monitoring ETL Listed Installations Special Installation RequirementsCentral Station Reporting Multi-Purpose Panic Control PanelNo Line Seizure Locating the PanelPlugging in the Phone Line Line SeizureTo activate a portable panic sensor Plugging in the PowerPowering up the System Adjusting the Speaker VolumeUtility Access Code 2 Installer Code Access CodesMaster Access Code Utility Access Code 1 Dealer CodeSetting the Clock Entering Program ModeChanging an Access Code Function Default Range Desired Setting Numbered Options Settings¾ To hear the current setting for each option ¾ To change an option settingOption 1 Panel Voice Range = On/Off Default = On¾ To turn Panel Voice On or Off Option 5 Numeric Pager/Voice Event Notification Phone Option 2 Account NumberOption 3 Primary Phone Number Option 4 Secondary Phone NumberOption 9 Downloader Code Phone Mod 1 SettingsOption 7 Downloader Phone Number Option 8 Phone LockOption 12 Numeric Pager/Voice Event Notification Phone Phone Mod 2 SettingsPhone Mod 3 Settings Option 11 Phone ModOption 14 Auto Phone Test Option 15 RF TimeoutOption 17 AC Power Failure Report Option 13 Dtmf DialingOption 19 Fail to Communicate Option 18 CPU Low Battery ReportRange = On/Off Default = Ring/Hang/Ring SettingsOption 23 300 Baud Option 21 Call Button EnableOption 22 Downloader Enable Option 26 AVM ModeOption 27 RF Jam Detect Option 28 Access Code LengthRange = 3-6 Default = Access Code Length DefaultsOption 33 Modem Sensitivity Option 30 Demo ModeOption 31 Programming Report Option 32 Supervisory TimeOption 37 VOX Receiver Gain Option 38 Alarm Cancel TimeoutOption 39 No Audio on Alarm Cancel Option 36 Manual Mic GainOption 42 Siren Time Out Exiting Programming ModeResetting Memory to Defaults Using CareGard with Activity Check SetHome and Away Setting up Medication RemindersAcknowledging Medication Reminders Sensor Type To Program Adding Replacing SensorsSupervised vs. Not Supervised Programming SensorsDoor/Window Sensor type possibilities Sensor Type To Trip Sensor Type Options System AC PowerBackup Battery Deleting SensorsSensor Supervisory Failure Sensor Low BatteryReplacing the Backup Battery ¾ To replace the backup batteryCentral Station Communication Sensor TestingAutomatic Phone Test Phone TestPager Reporting Message Pager CommunicationVoice Event Notification Remote Phone OperationRemote Phone Operation System Function Phone CommandProblem Solution Troubleshooting GuideNumerics Index