GE 60-883-95R Adding Replacing Sensors, Supervised vs. Not Supervised, Programming Sensors

Page 25

Home and Away

If you will be away from home or unable to acknowledge medication reminders it’s necessary to temporarily turn them off.

¾When you’re Away from home:

ŠPress the Power/Home/Away button. The system announces “Medication Reminder Off”. If the Activity Check is scheduled it will be turned off as well. The Power/Home/Away button will blink when Medication Reminders are off.

¾When you return Home:

ŠPress the Power/Home/Away button. The system announces “Medication Reminder On.” If the Activity Check is scheduled it will be turned on as well.

Adding/

Replacing

Sensors

CareGard allows up to 24 sensors to be learned into the system. There are two methods for add- ing a sensor to the system. The first method uses the menu button on the back of the panel, the second uses the programming buttons.

Supervised vs. Not Supervised

Most sensors supported by CareGard can be programmed to be supervised or not supervised. The panel monitors supervised sensors and sounds trouble beeps or turns the Status light on when there is a problem with the sensor.

In most situations sensors should be left in the Supervised state. Portable panic sensors should be Not Supervised.

To Add or Replace a Sensor using the Menu Button on the back of the Panel

Note

Pressing the Menu button cycles through 5 functions; Phone Test, Sensor Test, Medication Reminder, Add Sensors and Delete all Sensors. The panel will announce the current function each time the button is pressed.

Important !

It is necessary to move quickly between the steps when adding sensors. Read these steps carefully before attempting to add a sensor. You may have as little as 5 seconds to move between steps.

The following table describes how to program each type of sensor. For complete programming and mounting instructions see the Installation Instructions for the device.

 

 

Table 7: Programming Sensors

 

 

 

Sensor Type

 

To Program

 

 

 

 

 

 

Personal Help Button

1.

Repeatedly press the Menu button on the back of the panel until the panel announces “Add

Pendant Help Button

 

sensor. Press Status to select.”

2.

Press the Status button on the front of the panel.

 

3.

Press the button on the sensor.

 

4.

Repeatedly press the Power/Home/Away button until you hear the sensor type you want.

 

 

Personal Help Button type possibilities:

 

 

Emergency Sensor type not supervised

 

 

Emergency Sensor type supervised

 

5.

Press the Status button to accept the sensor.

 

 

The system will announce the sensor name, type and number.

 

 

 

Adding/Replacing Sensors

20

Image 25
Contents CareGard FCC Part 15 Information to the User GE InterlogixContents Medication Reminders Activity CheckAdding/Replacing Sensors Troubleshooting Sensor Testing Phone Communication TestingDeleting Sensors System Monitoring ETL Listed Installations Special Installation RequirementsCentral Station Reporting Multi-Purpose Panic Control PanelPlugging in the Phone Line Locating the PanelLine Seizure No Line SeizurePowering up the System Plugging in the PowerAdjusting the Speaker Volume To activate a portable panic sensorMaster Access Code Access CodesUtility Access Code 1 Dealer Code Utility Access Code 2 Installer CodeSetting the Clock Entering Program ModeChanging an Access Code ¾ To hear the current setting for each option Numbered Options Settings¾ To change an option setting Function Default Range Desired SettingOption 1 Panel Voice Range = On/Off Default = On¾ To turn Panel Voice On or Off Option 3 Primary Phone Number Option 2 Account NumberOption 4 Secondary Phone Number Option 5 Numeric Pager/Voice Event Notification PhoneOption 7 Downloader Phone Number Phone Mod 1 SettingsOption 8 Phone Lock Option 9 Downloader CodePhone Mod 3 Settings Phone Mod 2 SettingsOption 11 Phone Mod Option 12 Numeric Pager/Voice Event Notification PhoneOption 17 AC Power Failure Report Option 15 RF TimeoutOption 13 Dtmf Dialing Option 14 Auto Phone TestRange = On/Off Default = Option 18 CPU Low Battery ReportRing/Hang/Ring Settings Option 19 Fail to CommunicateOption 22 Downloader Enable Option 21 Call Button EnableOption 26 AVM Mode Option 23 300 BaudRange = 3-6 Default = Option 28 Access Code LengthAccess Code Length Defaults Option 27 RF Jam DetectOption 31 Programming Report Option 30 Demo ModeOption 32 Supervisory Time Option 33 Modem SensitivityOption 39 No Audio on Alarm Cancel Option 38 Alarm Cancel TimeoutOption 36 Manual Mic Gain Option 37 VOX Receiver GainResetting Memory to Defaults Exiting Programming ModeUsing CareGard with Activity Check Set Option 42 Siren Time OutHome and Away Setting up Medication RemindersAcknowledging Medication Reminders Supervised vs. Not Supervised Adding Replacing SensorsProgramming Sensors Sensor Type To ProgramDoor/Window Sensor type possibilities Sensor Type To Trip Sensor Type Options Backup Battery AC PowerDeleting Sensors SystemReplacing the Backup Battery Sensor Low Battery¾ To replace the backup battery Sensor Supervisory FailureAutomatic Phone Test Sensor TestingPhone Test Central Station CommunicationVoice Event Notification Pager CommunicationRemote Phone Operation Pager Reporting MessageRemote Phone Operation System Function Phone CommandProblem Solution Troubleshooting GuideNumerics Index