About this Manual
This manual provides advanced information for planning, installing programming, operating, and testing a CareGard system. Complete operation instructions are available in the CareGard User Instructions (Part No.
Special Installation Requirements
This system is designed to be used as an emergency notification system. Some installations may require configurations dictated by city or state codes, or insurance.
ETL Listed Installations
The following are requirements for ETL listed installations:
Basic System
•Control Panel
•Backup Battery
•Standard Class II 9 VAC 700 mA Power Transformer
•Wrist Panic
Digital Alarm Communicator System (UL 1635)
These options are required only if the system is set up for central station reporting.
•Option 3: Primary Phone Number programmed
•Option 10: Phone Mod 1 set to 0 or 1
•Option 14: Auto Phone Test set to 001
•Option 15: RF Timeout set to 4 hours
•Option 17: AC Power Failure Report set to 15 minutes
•Option 18: CPU Low Battery Report set to on
•Option 27: RF Jam Detect set to on
Home Health Care Signaling Equipment (UL 1637)
•Basic System
•Panic Sensor
Central Station Reporting
The panel has been tested with the following central station receivers using SIA and Contact ID reporting formats:
•Radionics D6600 Central Station Receiver
•
1 | About this Manual |