INSTALLATION INSTRUCTIONS OVERVIEW

Location - All Models

Select a location near the center of the space to be heated. Overflow heat will circulate through doorways into adjacent rooms.

The furnace is to be located on an outside wall. Locate wall studs so that wall opening will be located between wall studs. One wall stud can be used for attachment of inside wall plate. The wall opening required as shown in Figure 3 is a minimum diameter of 6 1/4" (159 mm). The inside wall plate and the outside wall plate are large enough to permit a wall opening diameter of 8" (203 mm). A template is provided in furnace carton for positioning furnace on the wall. Also, refer to Figure 3 for positioning the furnace on wall and for locating gas line connection.

For large homes or spread-out floor plans, two or more furnaces are recommended.

Do not locate furnace where a door could swing over the outer casing, or where circulation could be retarded by furniture or cabinets. See Figure 4.

Do not install in a closet, alcove or small hallway where the furnace could be isolated by closing doors to the heated space. See Figures 5 and 6.

When location is selected, check the walls to make sure there are no obstructions such as pipes, electric wiring, etc., which would interfere with the installation of the furnace or vent pipe.

See Page 18, Box 4 for dimensions.

Figure 3

Figure 4

Figure 5

Figure 6

Page 14

24632-0-0508

Image 14
Contents Installation Table of Contents Included in the BOX Hardware Packets Tools NeededHigh Altitude Specifications GAS SpecificationsSpecifications Unit Dimensions Important Safety Information Follow State and Local codes for installationSafety Information for Users of LP-GAS LP-GAS Warning OdorInstructions to Installer IntroductionRequirements for Massachusetts DIRECTLYBELOW. Keepclear OFALLOBSTRUC- TionsDescription US Installations1 Termination ClearancesGAS Supply Locating Gas SupplyGAS Supply ClearancesInstallation Instructions Overview Location All ModelsInstallation and Assembly Installation OverviewClearances to Combustibles Mounting Template for HWDV080BDV HWDV181BDV Pilot Hole Interior Installation of the Front of the Unit Cutting the Vent Tubes Marker Flue Outlet Tube Collar Exterior Installation of the Venting DIA. Vent CAP Collar Furnace Cement Screws Reassembly and Resealing VENT-AIR Intake System DIA. Vent CAP Collar Furnace Cement Screws Installation of Optional Blower KIT HW125SCB Installation of Optional Blower KIT HW125SCB Installation of Optional Blower KIT HW125SCB Pull blower cord from bottom to remove any excess wire from Before Operating Appliance Before Operating Appliance Before Operating Appliance What to do if YOU Smell GAS Operating Instructions What to do if YOU Smell GASLighting Instructions To Turn OFF GAS to AppliancePilot Flame Characteristics Main Burner Flame CharacteristicsMaintenance Instructions Operation Frequency Faults to be Remarks PreventedProblem Causes Solution TroubleshootingHOW to Order Repair Parts Parts List Index no Description HWDV080 HWDV181Bulb Clip Parts View Service Notes Service Notes Service Notes Freeburg Ave. Belleville, IL 62220 PH877-459-1583 FAX