Epson HWDV080DV(N Maintenance Instructions, Operation Frequency Faults to be Remarks Prevented

Page 40

MAINTENANCE INSTRUCTIONS

WARNING:

Prior to any maintenance operation, it will be necessary to close the gas supply.

Only qualified personnel are allowed to operate these appliances without the front cabinet installed.

OPERATION

FREQUENCY

FAULTS TO BE

REMARKS

 

 

PREVENTED

 

External cleaning

As required

Dirty exterior

With wet rag or soft cloth. No

 

 

 

qualified persons required

General cleaning of appliances

As required. It is advisable to

Recirculation of suspended

To be performed by qualified

 

perform this operation annually.

particles in surrounding air,

personnel

 

 

deposits on the appliance

 

Gas leakage control

Only if the equipment has been

Gas leakage

Check with soapy water solution.

 

moved or if any gas circuit ele-

 

To be performed by qualified

 

ment has been changed.

 

personnel

Cleaning of pilot burner

As required

Clogging of same

To be performed by qualified

 

 

 

personnel

In case of doubt, please check with our Customer Service Department

Use soft dry cloth to wipe cabinet.

Use compressed air to remove dust from around pilot and main burner.

Use a vacuum cleaner or compressed air to clean cap and air inlet ring.

CLEANING BURNER AND PILOT

Cleaning of the burner and pilot may be performed by gently vacuuming loose particles and dust from the burner ports and cleaning the air intake. Clean the pilot burner with compressed air, pipe cleaner or toothbrush. Do not insert any object (pin, drill bit, etc.) through pilot orifice. This will destroy the orifice. Any service which requires disconnecting the gas supply line must be performed by a qualified service person.

Note: It is recommended to shut off pilot in off season.

Page 40

24632-0-0508

Image 40
Contents Installation Table of Contents Included in the BOX Hardware Packets Tools NeededSpecifications GAS SpecificationsHigh Altitude Specifications Unit Dimensions Important Safety Information Follow State and Local codes for installationSafety Information for Users of LP-GAS LP-GAS Warning OdorInstructions to Installer IntroductionRequirements for Massachusetts DIRECTLYBELOW. Keepclear OFALLOBSTRUC- TionsDescription US Installations1 Termination ClearancesGAS Supply Locating Gas SupplyGAS Supply ClearancesInstallation Instructions Overview Location All ModelsInstallation and Assembly Installation OverviewClearances to Combustibles Mounting Template for HWDV080BDV HWDV181BDV Pilot Hole Interior Installation of the Front of the Unit Cutting the Vent Tubes Marker Flue Outlet Tube Collar Exterior Installation of the Venting DIA. Vent CAP Collar Furnace Cement Screws Reassembly and Resealing VENT-AIR Intake System DIA. Vent CAP Collar Furnace Cement Screws Installation of Optional Blower KIT HW125SCB Installation of Optional Blower KIT HW125SCB Installation of Optional Blower KIT HW125SCB Pull blower cord from bottom to remove any excess wire from Before Operating Appliance Before Operating Appliance Before Operating Appliance What to do if YOU Smell GAS Operating Instructions What to do if YOU Smell GASLighting Instructions To Turn OFF GAS to AppliancePilot Flame Characteristics Main Burner Flame CharacteristicsMaintenance Instructions Operation Frequency Faults to be Remarks PreventedHOW to Order Repair Parts TroubleshootingProblem Causes Solution Parts List Index no Description HWDV080 HWDV181Bulb Clip Parts View Service Notes Service Notes Service Notes Freeburg Ave. Belleville, IL 62220 PH877-459-1583 FAX