Epson HWDV080DV(N, P)-1 installation instructions DIA. Vent CAP Collar Furnace Cement

Page 24

EXTERIOR INSTALLATION OF THE VENTING

4

5

6

If installing onto vinyl, aluminum, or any type of siding that may warp or discolor, attach vent shield using two of the screws that attach the outside wall mounting plate.

3” DIA. VENT CAP COLLAR

FURNACE CEMENT

Apply furnace cement (not provided) to 3" (76 mm) diameter flue outlet collar on combustion chamber and to 3" (76 mm) diameter collar on vent cap.

FLUE OUTLET TUBE

COLLAR OF

FLUE OUTLET

Attach 3" (76 mm) diameter flue outlet tube onto flue outlet collar on combustion chamber.

Page 24

24632-0-0508

Image 24
Contents Installation Table of Contents Included in the BOX Hardware Packets Tools NeededGAS Specifications SpecificationsHigh Altitude Specifications Unit Dimensions Important Safety Information Follow State and Local codes for installationSafety Information for Users of LP-GAS LP-GAS Warning OdorInstructions to Installer IntroductionRequirements for Massachusetts DIRECTLYBELOW. Keepclear OFALLOBSTRUC- TionsDescription US Installations1 Termination ClearancesGAS Supply Locating Gas SupplyGAS Supply ClearancesInstallation Instructions Overview Location All ModelsInstallation and Assembly Installation OverviewClearances to Combustibles Mounting Template for HWDV080BDV HWDV181BDV Pilot Hole Interior Installation of the Front of the Unit Cutting the Vent Tubes Marker Flue Outlet Tube Collar Exterior Installation of the Venting DIA. Vent CAP Collar Furnace Cement Screws Reassembly and Resealing VENT-AIR Intake System DIA. Vent CAP Collar Furnace Cement Screws Installation of Optional Blower KIT HW125SCB Installation of Optional Blower KIT HW125SCB Installation of Optional Blower KIT HW125SCB Pull blower cord from bottom to remove any excess wire from Before Operating Appliance Before Operating Appliance Before Operating Appliance What to do if YOU Smell GAS Operating Instructions What to do if YOU Smell GASLighting Instructions To Turn OFF GAS to AppliancePilot Flame Characteristics Main Burner Flame CharacteristicsMaintenance Instructions Operation Frequency Faults to be Remarks PreventedTroubleshooting HOW to Order Repair PartsProblem Causes Solution Parts List Index no Description HWDV080 HWDV181Bulb Clip Parts View Service Notes Service Notes Service Notes Freeburg Ave. Belleville, IL 62220 PH877-459-1583 FAX