Epson P)-1, HWDV080DV(N installation instructions GAS Specifications, High Altitude Specifications

Page 5

GAS SPECIFICATIONS

MODEL

FUEL

 

MAXIMUM INPUT

MINIMUM INPUT

 

 

 

 

 

HW080

 

 

8,000 Btu/hr

5,000 Btu/hr

HW181

Propane/LP -- Natural gas

 

18,000 Btu/hr

9,000 Btu/hr NAT

 

 

9,500 Btu/hr LP

 

 

 

 

MANIFOLD PRESSURE

 

 

Natural gas: 4" water column pressure

 

Propane/LP gas: 10.0" water column pressure

 

 

Gas Inlet

 

3/8"

 

SUPPLY

MINIMUM PRESSURE

 

MAXIMUM PRESSURE

Natural Gas

5" W.C.P.

 

10.5" W.C.P.

LP Gas

11" W.C.P.

 

13" W.C.P.

Note: Appliance input ratings are based on sea level operation and need not be changed for operation up to 2,000 feet.

SPECIFICATIONS

MODELS

 

HWDV080(B)DV

HWDV181(B)DV

 

 

 

 

COMBUSTION

 

ATMOSPHERIC BURNER

STANDARD HEATING SPACE

 

85 - 250 Sq. Ft.

169 - 529 Sq. Ft.

 

HEIGHT

21 11/16"

25

3/16"

EXTERNAL DIMENSIONS INCHES

WIDTH

18

5/16"

22

5/16"

 

DEPTH

8

7/8"

9

3/8"

NET WEIGHT LBS.

 

33.5

45.5

MAX. GAS CONSUMPTION

 

8,000 Btu/hr.

18,000 Btu/hr.

SAFETY DEVICES

 

Safety valve (thermocouple)

Warning: This direct vent wall furnace is equipped for Natural or Propane gas. Field conversion is not permitted.

HIGH ALTITUDE SPECIFICATIONS

For altitudes/elevations above 2,000 feet (610 m), input ratings should be reduced at the rate of 4% for each 1,000 feet (305 m) above sea level. Canadian High Altitudes for locations having an elevation above mean sea level between 2,000 feet (609.9 m) and 4,500 feet

(1,370 m), use orifices as indicated in the following table:

 

0 - 2,000 feet (0 - 610 m)

2,000 - 4,500 feet (610 - 1 370 m)

Model

Main Burner Orifice/Gas Pressure

Main Burner Orifice/Gas Pressure

 

Natural Gas

LP Gas

Natural Gas

LP Gas

HW080

#55 (4")

#66 (10")

#1.27 mm (4")

#67 (10")

HW181

#49 (4")

#56 (10")

#50 (4")

#57 (10")

24632-0-0508

Page 5

Image 5
Contents Installation Table of Contents Included in the BOX Tools Needed Hardware PacketsHigh Altitude Specifications GAS SpecificationsSpecifications Unit Dimensions Follow State and Local codes for installation Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASIntroduction Instructions to InstallerDIRECTLYBELOW. Keepclear OFALLOBSTRUC- Tions Requirements for MassachusettsTermination Clearances Description US Installations1Locating Gas Supply GAS SupplyClearances GAS SupplyLocation All Models Installation Instructions OverviewInstallation Overview Installation and AssemblyClearances to Combustibles Mounting Template for HWDV080BDV HWDV181BDV Pilot Hole Interior Installation of the Front of the Unit Cutting the Vent Tubes Marker Flue Outlet Tube Collar Exterior Installation of the Venting DIA. Vent CAP Collar Furnace Cement Screws Reassembly and Resealing VENT-AIR Intake System DIA. Vent CAP Collar Furnace Cement Screws Installation of Optional Blower KIT HW125SCB Installation of Optional Blower KIT HW125SCB Installation of Optional Blower KIT HW125SCB Pull blower cord from bottom to remove any excess wire from Before Operating Appliance Before Operating Appliance Before Operating Appliance What to do if YOU Smell GAS What to do if YOU Smell GAS Operating InstructionsTo Turn OFF GAS to Appliance Lighting InstructionsMain Burner Flame Characteristics Pilot Flame CharacteristicsOperation Frequency Faults to be Remarks Prevented Maintenance InstructionsProblem Causes Solution TroubleshootingHOW to Order Repair Parts Index no Description HWDV080 HWDV181 Parts ListBulb Clip Parts View Service Notes Service Notes Service Notes Freeburg Ave. Belleville, IL 62220 PH877-459-1583 FAX