BEFORE OPERATING APPLIANCE
WARNING
Improper installation, adjustments, alterations, service or maintenance can cause property damage, personal injury or loss of life. Installation and service must be conducted by a Qualified Service Person.
Under no circumstances should these heaters be modified.
In case of gas leaks, close gas valve and call your Qualified Ser- vice Person.
ATTENTION INSTALLER: INSTRUCT YOUR CUSTOMER ABOUT THE CORRECT OPERATION OF THE APPLIANCE BEFORE YOU LEAVE.
Air must be purged from pipeline by depressing to pilot setting or by loosening gas inlet connection until you smell gas. Qualified service persons must conduct this procedure only for the first time the heater is operated, in a well ventilated room, with doors and windows open. If loosened, tighten gas inlet connection. Check gas inlet connection with a soapy water solution to assure no leaks are present. Do not regulate primary air burner. They both have been adjusted according to corresponding gas. If burner produces a permanent bright yellow flame when igniting or when ignited, call: (877)
ATTENTION INSTALLER:
The appliance must be isolated from the gas supply piping system by closing its equipment
The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
DO NOT RECESS INTO WALLS, BOOKCASES, ETC.
CHECK THE FOLLOWING BEFORE OPERATING APPLIANCE