Goodman Mfg MVC95, CVC9/95 installation instructions Product Description

Page 2

SHIPPING INSPECTION

6

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

6

TO THE INSTALLER

6

IMPORTANT NOTE TO THE OWNER REGARDING PRODUCT WARRANTY

6

PRODUCT DESCRIPTION

7

FEATURES

7

PRODUCT APPLICATION

7

LOCATION REQUIREMENTS & CONSIDERATIONS

8

CLEARANCES AND ACCESSIBILITY

9

FURNACE SUSPENSION

9

EXISTING FURNACE REMOVAL

9

THERMOSTAT LOCATION

10

COMBUSTION & VENTILATION AIR REQUIREMENTS

10

INSTALLATION POSITIONS

10

HORIZONTAL APPLICATIONS & CONSIDERATIONS

11

DRAIN TRAP AND LINES

11

LEVELING

11

ALTERNATE VENT/FLUE AND COMBUSTION AIR CONNECTIONS

11

ALTERNATE ELECTRICAL AND GAS LINE CONNECTIONS

12

DRAIN PAN

12

FREEZE PROTECTION

12

FURNACE SUSPENSION

12

PROPANE GAS/HIGH ALTITUDE INSTALLATIONS

12

VENT/FLUE PIPE & COMBUSTION AIR PIPE

12

DUAL CERTIFICATION: NON-DIRECT/DIRECTVENT

12

MATERIALS AND JOINING METHODS

13

PROPER VENT/FLUE AND COMBUSTION AIR PIPING PRACTICES

13

TERMINATION LOCATIONS

13

CANADIAN VENTING REQUIREMENTS

14

STANDARD FURNACE CONNECTIONS

14

ALTERNATE FURNACE CONNECTIONS

15

NON-DIRECTVENT (SINGLE PIPE) PIPING

17

DIRECT VENT (DUAL PIPE) PIPING

18

VENT/INTAKE TERMINATIONS FOR INSTALLATION OF MULTIPLE DIRECT VENT FURNACES

20

CONCENTRIC VENT TERMINATION

20

SIDE WALL VENT KIT

20

CONDENSATE DRAIN LINES & DRAIN TRAP

21

STANDARD RIGHT OR LEFT SIDE DRAIN HOSE CONNECTIONS

21

UPRIGHT INSTALLATIONS-TRAP ON RIGHT SIDE

22

UPRIGHT INSTALLATIONS-TRAP ON LEFT SIDE

24

HORIZONTAL INSTALLATIONS

25

ELECTRICAL CONNECTIONS

27

WIRING HARNESS

27

115 VOLT LINE CONNECTIONS

27

JUNCTION BOX RELOCATION

27

24 VOLT THERMOSTAT WIRING

28

SINGLE-STAGEHEATING THERMOSTAT APPLICATION

28

24 VOLT DEHUMIDISTAT WIRING

29

FOSSIL FUEL APPLICATIONS

29

2

Image 2
Contents Type FSP Category IV Direct or Non Direct Vent Air Furnace Product Description Normal Sequence of Operation Troubleshooting Safety Precautions What to do if YOU Smell GASProduct Description & Application ElectrostaticdischargeesdprecautionsTotheinstaller ShippinginspectionProductapplication FeaturesProduct Description Location Requirements & Considerations Existingfurnaceremoval ClearancesandaccessibilityFurnacesuspension Thermostatlocation Installation PositionsCombustion & Ventilation AIR Requirements HorizontalFurnace AlternateVent/FlueLocation RecommendedInstallationPositionsHorizontal Applications & Considerations Propane GAS/HIGH Altitude Installations VENT/FLUE Pipe & Combustion AIR PipeTerminationlocations MaterialsandjoiningmethodsPROPERVENT/FLUEANDCOMBUSTIONAIRPIPINGPRACTICES Canadianventingrequirements Increased Clearance ConfigurationVent Termination Clearances StandardfurnaceconnectionsVent/FluePipeCuts AlternatefurnaceconnectionsRemove Pipe Relocate Upflow NON-DIRECTVENTSINGLEPIPEPIPINGHorizontalTerminationSinglePipe Vertical Termination Single PipeAlternate Vertical Termination Single Pipe DirectventdualpipepipingVertical Terminations Dual Pipe Standard Horizontal Terminations Dual PipeConcentricventtermination Alternate Horizontal Vent Termination Dual PipeHorizontalVentingOfMultipleUnits Side Wall Vent KITStandardrightorleftsidedrainhoseconnections Condensate Drain Lines & Drain TrapHose and Tube Identification UPRIGHTINSTALLATIONS-TRAPONRIGHTSIDE Drain Trap MountingExternally UPRIGHTINSTALLATIONS-TRAP on Leftside Horizontalinstallations Counterflow furnacesCut Junctionbox Relocation WiringharnessElectrical Connections 115VOLT Line ConnectionsSINGLE-STAGE Heatingthermostatapplication Thermostat Wiring Diagrams24VOLTTHERMOSTATWIRING Accessory load specifications are as follows Fossilfuelapplications24VOLTHUMIDIFIER Accessories WiringGAS Supply and Piping HighaltitudederateGaspipingconnections Natural Gas Capacity of Pipe Cubic Feet of Gas Per Hour CFHHorizontal Upflow Model Gas Piping ConnectionsPropanegastanksandpiping PropaneGasInstallationTypCoupling Degree elbow Inch close nipple Duct Work -AIR Flow Propane Gas Piping ChartCirculating AIR & Filters Checking Duct StaticDuctFlangeCutOuts Consult proper tables for the quantity of airChecking Static Pressure 80% Furnace Shown, 90% Similar BottomreturnairopeningupflowmodelsFollowing figure shows possible filter locations Startup Procedure & AdjustmentStartup Procedure &ADJUSTMENT If you smell gas after five minutes, immediately follow TemperatureSet the thermostat to the lowest setting White-Rodgers Model 36G54 Two-StageHoneywell Model VR9205 Connected to Manometer GasmanifoldpressuremeasurementandadjustmentTurn on the gas supply Measuring Inlet Gas Pressure Alt. MethodTemperaturerise GasinputratemeasurementnaturalgasonlyTemperature Rise Measurement CirculatorblowerspeedsAirflowTable Comfortnet System Heat Off Delay DipswitchesBlowerheat Offdelay Timings OverviewSystem Wiring using Four-Wires System System OperatingPear. Use Touch To step through the list of installed equipComfortnetsystemadvancedfeatures Value. TouchConfiguration Networktroubleshooting Is 30 seconds Non-CT compatible single stage AC unitNormal Sequence of Operation SystemtroubleshootingPower UP HeatingmodeFanonlymode Operational Checks & Safety Circuit DescriptionCoolingmode Troubleshooting Troubleshooting & Maintenance Operational ChecksSafety Circuit Description Follow the manufacturer’s directions for service Troubleshooting & MaintenanceMaintenance Induced Draft Blower Transformer Door Switch Before Leaving AN InstallationRepair and Replacement Parts MiscellaneousDIP Switches BankTroubleshooting Chart InternalLimit Chart MessageInvalid Trips Status Codes Wiring Diagram CVC9AA, *MVC95AACVC9AB, *MVC95AB

MVC95, CVC9/95 specifications

Goodman Manufacturing has established itself as a leader in the HVAC industry, and among its stellar lineup, the Goodman CVC9/95 and MVC95 stand out for their remarkable features, technologies, and efficiency.

The Goodman CVC9/95 is a high-performance gas furnace, designed for homeowners seeking reliability and cost-effective heating solutions. It operates with an impressive 95% Annual Fuel Utilization Efficiency (AFUE), which means that a significant portion of the fuel it consumes is converted into heat. This level of efficiency not only contributes to lower energy bills but also reduces greenhouse gas emissions, making it an environmentally friendly choice.

One of the standout features of the CVC9/95 is its multi-speed ECM blower motor. This technology adjusts the airflow according to the heating demands of the home, ensuring consistent and comfortable temperatures. The ECM motor also operates quietly, enhancing the comfort of your living space without the disruptive noise often associated with traditional furnaces.

The MVC95, on the other hand, offers similar efficiency with its also 95% AFUE rating. This model is equipped with a patented ignition system that enhances reliability with minimal maintenance needs. Its durable construction includes a heavy-gauge steel cabinet and an insulated blower compartment that minimizes heat loss. This design not only supports optimal performance but also contributes to its longevity.

Both models come with a self-diagnostic control board that provides straightforward troubleshooting capabilities, making it easier for technicians to ensure that your system is operating at peak performance. This feature aids in timely maintenance, which is crucial for extending the lifespan of the unit.

Additionally, Goodman backs their products with a strong warranty, offering a lifetime limited warranty on the heat exchanger and a 10-year limited parts warranty. This assurance provides homeowners peace of mind regarding their investment.

In the landscape of HVAC solutions, the Goodman CVC9/95 and MVC95 models exemplify a commitment to quality, efficiency, and advanced technology. Whether for new constructions or replacements, these furnaces offer superior heating performance coupled with modern conveniences, making them an invaluable choice for homeowners seeking effective climate control solutions. With their low emissions and high efficiency, choosing Goodman means investing in both comfort and sustainability.