Table 7 – Electrical Data
|
| VOLTS |
| OPERATING |
| UNIT | MAX WIRE | MAX FUSE/ |
| ||
FURNACE |
| VOLTAGE* | MAX UNIT | MIN WIRE | |||||||
HERTZ |
| AMPACITY# | LENGTH} | CKT BKR{ | |||||||
| MODEL | (VOLTS) |
| (AMPS) | GAGE | ||||||
| PHASE |
|
| (AMPS) | FT. (M) | (AMPS) | |||||
|
|
|
|
|
|
| |||||
|
|
| MAX | MIN |
|
| |||||
|
|
|
|
|
|
|
|
|
| ||
045 | 1 | 127 | 104 | 8.1 | 10.9 | 34 (10) | 15 | 14 | |||
070 | 1 | 127 | 104 | 9.5 | 12.6 | 29 (9) | 15 | 14 | |||
090 | 1 | 127 | 104 | 10.3 | 13.4 | 27 (8) | 15 | 14 | |||
110 | 1 | 127 | 104 | 13.1 | 16.9 | 34 (10) | 20 | 12 | |||
135 |
| 1 | 127 | 104 | 13.1 | 16.9 | 34 (10) | 20 | 12 |
* Permissible limits of the voltage range at which the unit operates satisfactorily.
#Unit ampacity = 125 percent of largest operating component’s full load amps plus 100 percent of all other potential operating components’ (EAC, humidifier, etc.) full load amps.
{
} Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.
GAS
SUPPLY
MANUAL
SHUTOFF
VALVE (REQUIRED)
SEDIMENT TRAP
UNION
58PHA
A02035
Fig. 22 - Typical Gas Pipe Arrangement
ELECTRICAL CONNECTIONS
!WARNING
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Blower access panel door switch opens
See Fig. 25 for field wiring diagram showing typical field
!WARNING
ELECTRICAL SHOCK AND FIRE HAZARD
Failure to follow this warning could result in personal injury, death, or property damage.
The cabinet MUST have an uninterrupted or unbroken ground according to NEC ANSI/NFPA
21