Carrier 58PHA/PHX instruction manual Furnace Control

Page 24

BLOWER OFF-DELAY

24-V THERMOSTAT TERMINALS

3-AMP FUSE

LED OPERATION

&DIAGNOSTIC

TWINNING AND/OR

COMPONENT TEST

TERMINAL

HUMIDIFIER TERMINAL (24-VAC 0.5 AMP. MAX)

58PHA

LIGHT

BLOWER SPEED

HEAT

COOL

TRANSFORMER

24-VAC CONNECTIONS

SELECTION FAN

TERMINALS

SPARE 2

SPARE 1

115-VAC (L2)

NEUTRAL

CONNECTIONS

EAC-1 TERMINAL

(115-VAC 1.0 AMP. MAX.)

115-VAC (L1)

NEUTRAL

CONNECTIONS

PL1-LOW VOLTAGE

DRAIN HARNESS

CONNECTOR

PL2-HOT SURFACE

IGNITER & INDUCER

MOTOR CONNECTOR

A08063

Fig. 24 - Furnace Control

 

 

 

 

 

 

FIELD 24-V WIRING

 

 

 

 

 

 

FIELD 115-, 208/230-, 460-V WIRING

 

 

 

 

 

 

FACTORY 24-V WIRING

 

 

 

 

 

 

FACTORY 115-V WIRING

 

 

 

NOTE 2

 

THERMOSTAT

 

 

 

FIVE WIRE

 

W C R

G Y

FIELD-SUPPLIED

 

 

 

TERMINALS

 

 

 

 

 

 

 

THREE-WIRE

 

 

 

 

DISCONNECT

 

HEATING-ONLY

 

 

 

 

208/230- OR

BLOWER DOOR SWITCH

 

 

 

 

 

 

 

 

460-V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THREE

BLK

BLK

 

 

W

 

 

PHASE

 

 

 

 

 

WHT

WHT

 

C

R

 

 

 

 

O

 

 

 

 

 

 

 

N

 

 

 

208/230-V

 

GND

GND

T

 

 

 

SINGLE

115-V FIELD-

AUXILIARY

R

G

 

 

PHASE

O

 

 

 

 

 

SUPPLIED

J-BOX

L

COM

 

 

GND

DISCONNECT

 

 

NOTE 1

 

CONDENSING

 

 

 

 

Y/Y2

 

UNIT

 

 

 

 

 

 

 

 

 

 

 

24-V

 

TWO

 

 

 

TERMINAL

 

WIRE

 

 

 

 

BLOCK

 

 

 

 

 

FURNACE

NOTES: 1.

Connect Y-terminal in furnace as shown for proper blower operation.

 

 

2. Some thermostats require a "C" terminal connection as shown.

 

 

 

 

3. If any of the original wire, as supplied, must be replaced, use same type or equivalent wire.

A99440

Fig. 25 - Heating and Cooling Application Wiring Diagram with 1-Stage Thermostat

24

Image 24
Contents Ama Safety Considerations Furnace Reliability HazardIntroduction CUT HazardCodes and Standards Clearances to CombustiblesElectrostatic Discharge ESD Precautions Procedure VentingLocation GeneralCarbon Monoxide Poisoning Hazard Electrical Operation Hazard Personal Injury AND/OR Property Damage HazardAIR for Combustion Ventilation Fire HazardFurnace Corrosion Hazard Location Relative to Cooling EquipmentACH Installation Combination of Indoor and Outdoor AirBottom Return Air Inlet Side Return Air InletDownflow Installation Leveling LegsA08556 Opening Dimensions In. mm Suspended Furnace SupportPlatform Furnace Support Roll-Out ProtectionFilter Arrangement Carbon Monoxide and Poisoning Hazard AIR DuctsGeneral Requirements Ductwork Acoustical Treatment Supply Air ConnectionsUpflowdownflow Horizontal Horizontal Suspension with Straps Return Air Connections GAS Piping Fire or Explosion HazardFurnace Overheat Hazard Air Delivery CFM With Filter Maximum Capacity of PipeUpflow Return Air Configurations and Restrictions Horizontal Return Air Configurations and Restrictions Electrical Data Electrical Connections Electrical Shock HazardElectrical Shock and Fire Hazard Wiring Furnace MAY not OperateBOX Relocation Electrical Connection to J-BOXPower Cord Installation in Furnace J-BOX BX Cable Installation in Furnace J-BOXAccessories VentingFurnace Control General Venting Requirements Masonry Chimney RequirementsSingle-Stage Furnace with Single-Speed Air Con Ditioner Humidfier Appliance Application Requirements Internal Area of ChimneyChimney Inspection Chart Additional Venting Requirements Burn HazardSidewall Venting Upflow Application-Vent Elbow Up See Notes 1,2,4,5,7,8,9 on See Notes 1,2,4,5,7,8,9 Using Tin Snips to Cut Tie Points Venting Notes for FiguresRounded End of Knockout START-UP, ADJUSTMENT, and Safety Check Fire and Explosion HazardFurnace Damage Hazard Canada Follow exclusively the National Fuel Gas CodeAltitude Derate Multiplier for U.S.A Gas Control Valve Check Safety Controls Speed SelectionFurnace Overheating Hazard Checklist Gas Rate Cu Ft./HrA08220 A08220A Service and Maintenance Procedures Electrical Controls and Wiring Electrical Shock HazardFIRE, INJURY, or Death Hazard Electrical SHOCK, Fire or Explosion HazardA08221 Service Care and Maintenance Fire or Explosion Hazard Cleaning AND/OR Replacing AIR FilterCarbon Monoxide Poisoning Fire Hazard Filter Size Information In. / mmCleaning Heat Exchanger Unit Damage HazardIgniter Position-Side View Cleaning Heat Exchanger Cell Sequence of OperationCooling Mode Thermidistat ModeContinuous Blower Mode Two-Speed CoolingWiring Diagrams TroubleshootingHeat pump Wiring Diagram Troubleshooting Guide Catalog No 58PHA---03SI