Carrier 58PHA/PHX instruction manual Upflow Application-Vent Elbow Up

Page 31

SEE NOTES: 1,2,4,7,8,9 on the page following these figures

A03208

Fig. 34 - Upflow Application-Vent Elbow Up

SEE NOTES: 1,2,3,4,7,8,9 on the pages following these figures

A03209

Fig. 35 - Upflow Application-Vent Elbow Right

SEE NOTES:1,2,3,4,5,7,8,9

58PHA

 

on the page following

 

these figures

 

 

A03210

Fig. 36 - Downflow Application-Vent Elbow Up then Left

SEE NOTES: 1,2,4,5,7,8,9 on the page following these figures

A03211

Fig. 37 - Downflow Application-Vent Elbow Up

31

Image 31
Contents Ama Furnace Reliability Hazard Safety ConsiderationsCUT Hazard IntroductionClearances to Combustibles Codes and StandardsVenting Electrostatic Discharge ESD Precautions ProcedureGeneral LocationCarbon Monoxide Poisoning Hazard Personal Injury AND/OR Property Damage Hazard Electrical Operation HazardLocation Relative to Cooling Equipment AIR for Combustion VentilationFire Hazard Furnace Corrosion HazardACH Side Return Air Inlet InstallationCombination of Indoor and Outdoor Air Bottom Return Air InletLeveling Legs Downflow InstallationA08556 Roll-Out Protection Opening Dimensions In. mmSuspended Furnace Support Platform Furnace SupportDuctwork Acoustical Treatment Supply Air Connections Filter Arrangement Carbon Monoxide and Poisoning HazardAIR Ducts General RequirementsUpflowdownflow Horizontal Horizontal Suspension with Straps GAS Piping Fire or Explosion Hazard Return Air ConnectionsFurnace Overheat Hazard Maximum Capacity of Pipe Air Delivery CFM With FilterUpflow Return Air Configurations and Restrictions Horizontal Return Air Configurations and Restrictions Electrical Connections Electrical Shock Hazard Electrical DataElectrical Shock and Fire Hazard Electrical Connection to J-BOX WiringFurnace MAY not Operate BOX RelocationVenting Power Cord Installation in Furnace J-BOXBX Cable Installation in Furnace J-BOX AccessoriesFurnace Control Masonry Chimney Requirements General Venting RequirementsSingle-Stage Furnace with Single-Speed Air Con Ditioner Humidfier Internal Area of Chimney Appliance Application RequirementsChimney Inspection Chart Burn Hazard Additional Venting RequirementsSidewall Venting Upflow Application-Vent Elbow Up See Notes 1,2,4,5,7,8,9 on See Notes 1,2,4,5,7,8,9 Venting Notes for Figures Using Tin Snips to Cut Tie PointsRounded End of Knockout Fire and Explosion Hazard START-UP, ADJUSTMENT, and Safety CheckFurnace Damage Hazard Follow exclusively the National Fuel Gas Code CanadaAltitude Derate Multiplier for U.S.A Gas Control Valve Speed Selection Check Safety ControlsFurnace Overheating Hazard Gas Rate Cu Ft./Hr ChecklistA08220 A08220A Electrical SHOCK, Fire or Explosion Hazard Service and Maintenance ProceduresElectrical Controls and Wiring Electrical Shock Hazard FIRE, INJURY, or Death HazardA08221 Service Filter Size Information In. / mm Care and Maintenance Fire or Explosion HazardCleaning AND/OR Replacing AIR Filter Carbon Monoxide Poisoning Fire HazardUnit Damage Hazard Cleaning Heat ExchangerIgniter Position-Side View Sequence of Operation Cleaning Heat Exchanger CellTwo-Speed Cooling Cooling ModeThermidistat Mode Continuous Blower ModeTroubleshooting Wiring DiagramsHeat pump Wiring Diagram Troubleshooting Guide Catalog No 58PHA---03SI