58PHA
Table 12 – Gas Rate (Cu Ft./Hr.)
SECONDS |
| SIZE OF TEST DIAL |
| SECONDS |
| SIZE OF TEST DIAL | ||||
FOR 1 REVOLUTION | 1 |
| 2 Cu Ft. |
| 5 Cu Ft. | FOR 1 REVOLUTION | 1 Cu Ft. |
| 2 Cu Ft. | 5 Cu Ft. |
Cu Ft. |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
| |
10 | 360 |
| 720 |
| 1800 | 50 | 72 |
| 144 | 360 |
11 | 327 |
| 655 |
| 1636 | 51 | 71 |
| 141 | 355 |
12 | 300 |
| 600 |
| 1500 | 52 | 69 |
| 138 | 346 |
13 | 277 |
| 555 |
| 1385 | 53 | 68 |
| 136 | 340 |
14 | 257 |
| 514 |
| 1286 | 54 | 67 |
| 133 | 333 |
15 | 240 |
| 480 |
| 1200 | 55 | 65 |
| 131 | 327 |
16 | 225 |
| 450 |
| 1125 | 56 | 64 |
| 129 | 321 |
17 | 212 |
| 424 |
| 1059 | 57 | 63 |
| 126 | 316 |
18 | 200 |
| 400 |
| 1000 | 58 | 62 |
| 124 | 310 |
19 | 189 |
| 379 |
| 947 | 59 | 61 |
| 122 | 305 |
20 | 180 |
| 360 |
| 900 | 60 | 60 |
| 120 | 300 |
21 | 171 |
| 343 |
| 857 | 62 | 58 |
| 116 | 290 |
22 | 164 |
| 327 |
| 818 | 64 | 56 |
| 112 | 281 |
23 | 157 |
| 313 |
| 783 | 66 | 54 |
| 109 | 273 |
24 | 150 |
| 300 |
| 750 | 68 | 53 |
| 106 | 265 |
25 | 144 |
| 288 |
| 720 | 70 | 51 |
| 103 | 257 |
26 | 138 |
| 277 |
| 692 | 72 | 50 |
| 100 | 250 |
27 | 133 |
| 267 |
| 667 | 74 | 48 |
| 97 | 243 |
28 | 129 |
| 257 |
| 643 | 76 | 47 |
| 95 | 237 |
29 | 124 |
| 248 |
| 621 | 78 | 46 |
| 92 | 231 |
30 | 120 |
| 240 |
| 600 | 80 | 45 |
| 90 | 225 |
31 | 116 |
| 232 |
| 581 | 82 | 44 |
| 88 | 220 |
32 | 113 |
| 225 |
| 563 | 84 | 43 |
| 86 | 214 |
33 | 109 |
| 218 |
| 545 | 86 | 42 |
| 84 | 209 |
34 | 106 |
| 212 |
| 529 | 88 | 41 |
| 82 | 205 |
35 | 103 |
| 206 |
| 514 | 90 | 40 |
| 80 | 200 |
36 | 100 |
| 200 |
| 500 | 92 | 39 |
| 78 | 196 |
37 | 97 |
| 195 |
| 486 | 94 | 38 |
| 76 | 192 |
38 | 95 |
| 189 |
| 474 | 96 | 38 |
| 75 | 188 |
39 | 92 |
| 185 |
| 462 | 98 | 37 |
| 74 | 184 |
40 | 90 |
| 180 |
| 450 | 100 | 36 |
| 72 | 180 |
41 | 88 |
| 176 |
| 439 | 102 | 35 |
| 71 | 178 |
42 | 86 |
| 172 |
| 429 | 104 | 35 |
| 69 | 173 |
43 | 84 |
| 167 |
| 419 | 106 | 34 |
| 68 | 170 |
44 | 82 |
| 164 |
| 409 | 108 | 33 |
| 67 | 167 |
45 | 80 |
| 160 |
| 400 | 110 | 33 |
| 65 | 164 |
46 | 78 |
| 157 |
| 391 | 112 | 32 |
| 64 | 161 |
47 | 76 |
| 153 |
| 383 | 116 | 31 |
| 62 | 155 |
48 | 75 |
| 150 |
| 375 | 120 | 30 |
| 60 | 150 |
49 | 73 |
| 147 |
| 367 |
|
|
|
|
|
Checklist
1.Put away tools and instruments. Clean up debris.
2.Verify that blower
3.Verify that blower and burner access doors are properly installed.
4.Cycle test furnace with room thermostat.
5.Check operation of accessories per manufacturer’s instructions.
6.Review User’s Guide with owner.
7.Attach literature packet to furnace.
40