58PHA
!CAUTION
FURNACE MAY NOT OPERATE
Failure to follow this caution may result in intermittent furnace operation.
Furnace control must be grounded for proper operation or else control will lock out. Control must remain grounded through green/yellow wire routed to gas valve and manifold bracket screw.
115-V WIRING
Verify that the voltage, frequency, and phase correspond to that specified on unit rating plate. Also, check to be sure that service provided by utility is sufficient to handle load imposed by this equipment. Refer to rating plate or Table 7 for equipment electrical specifications.
U.S. Installations: Make all electrical connections in accordance with National Electrical Code (NEC) ANSI/NFPA
Canadian Installations: Make all electrical connections in accordance with Canadian Electrical Code CSA C22.1 or authorities having jurisdiction.
!WARNING
FIRE HAZARD
Failure to follow this warning could result in personal injury, death, or property damage.
Do not connect aluminum wire between disconnect switch and furnace. Use only copper wire.
Use a separate, fused branch electrical circuit with a properly sized fuse or circuit breaker for this furnace. See Table 7 for wire size and fuse specifications. A readily accessible means of electrical disconnect must be located within sight of the furnace.
NOTE: Proper polarity must be maintained for
J-BOX RELOCATION
NOTE: If factory location of
NOTE: On
1. Remove and save two screws holding
NOTE: The
2.Cut wire tie on loop in furnace wires attached to
3.Move
4.Fasten
5.Route
ELECTRICAL CONNECTION TO J-BOX
1.Remove cover from furnace
2.Attach electrical box to furnace
3.Route furnace power wires through holes in electrical box and
4.Route and secure field ground wire to green ground screw on
5.Connect line voltage leads as shown in Fig. 25.
6.Reinstall cover to
Electrical Box on Furnace Casing Side
See Fig. 23.
!WARNING
FIRE OR ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death, or property damage.
If
1.Select and remove a hole knockout in the casing where the electrical box is to be installed.
NOTE: Check that duct on side of furnace will not interfere with installed electrical box.
2.Remove the desired electrical box hole knockout and positionthe hole in the electrical box over the hole in the furnace casing.
3.Fasten the electrical box to casing by driving two fieldsupplied screws from inside electrical box into casing steel.
4.Remove and save two screws holding
5.Pull furnace power wires out of
6.Route furnace power wires through holes in casing and electrical box and into electrical box.
7.Pull field power wires into electrical box.
8.Remove cover from furnace
9.Route field ground wire through holes in electrical box and casing, and into furnace
10.Reattach furnace
11.Secure field ground wire to
12.Complete electrical box wiring and installation. Connect line voltage leads as shown in Fig. 25. Use best practices (NEC in U.S. and CSA C22.1 in Canada) for wire bushings, strain relief, etc.
13.Reinstall cover to