Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA, K5305-1V5 Pager Programming Fields

Page 31

Data Field Programming

*93 No. of Reports In Armed Period per Zone (Swinger Suppression)

0 = unlimited number of reports

1 = 1 report pair per zone per armed period 2 = 2 report pairs per zone per armed period

Selection limits the number of alarm/alarm restore message pairs per zone sent to the CS in an armed period.

SIA Guidelines: Must be set for option 1 or 2.

V20PSIA/V15PSIA:

Report Pairs: 1 = 1 report pair; 2 = 2 report pairs

Unlimited Reports Enable:

0 = restrict reports to the setting in entry 1

1 = unlimited reports for zones listed in zone list 7;

(use zone list 7 to list zones that require unlimited reporting; these zones ignore the setting in entry 1)

*94 Download Phone Number

Enter up to 20 digits as follows: 0–9, # +11 for “”,

# + 12 for “#”, # + 13 for a pause.

Enter the phone number of the downloading computer. Do not fill unused spaces. End field by entering ∗. To clear entries from field, press ∗94∗.

*95 Ring Count For Downloading

0–15 = number of rings before control picks up phone line.

Refer to the chart below and program accordingly.

phone

answer

down-

Set field 95 to…

 

module

machine

loading

 

yes

no

no

1-14 (not 0)

 

 

yes

yes

no

higher

than

number of

 

 

 

rings

set

on

answer

 

 

 

machine (e.g.,

if ans.

 

 

 

machine is 4 rings, set

 

 

 

this field to 5). This allows

 

 

 

access

to

the

phone

 

 

 

module

if

the

answer

 

 

 

machine is off.

 

yes

no

yes

1-14 (not 0)

 

 

yes

yes

yes

15 (bypasses

answer

 

 

 

machine)

 

 

no

no

no

0

 

 

 

no

yes

no

0

 

 

 

no

no

yes

1-14

 

 

 

no

yes

yes

15

 

 

 

NOTE: If “15” is entered to bypass an answering machine, and a 4285 or 4286 Phone Module is included in the system, you should note the following:

When calling in from an off-premises phone, the user should make the initial call, allow 1 or 2 rings only, then hang up, then call again. The phone module will now seize the line, and 2 long tones sound, followed by the usual voice prompt for the access code. If this procedure is not followed, phone module operation will not be possible.

*96 Command to Initialize CSID and Subscriber Account Number

Use this command, if necessary, to reset all subscriber account numbers and the internal CSID to the factory default values.

*97 Command to Reset System to Factory Default Values

Pressing ∗97 resets all data fields to the factory default values (shown on the Program Form).

IMPORTANT: Do not press ∗97 to load defaults if any programming has been done previously—data already programmed into the system will be changed!

*98 Command to Exit Program Mode (with installer code lockout)

Exits Programming Mode and prevents re-entry by: Installer Code + [8] + [0] + [0].

To enter the programming mode if ∗ 98 was used to exit, you must first power down the system. Then power up again, and press [∗] and [#] at the same time, within 50 seconds of powering up. See field *88 for other Program mode lockout options.

*99 Command to Exit Program Mode

Exits Programming Mode and allows re-entry by: Installer Code + [ 8] + [0] + [0]

or by: Pressing [∗] and [#] at the same time, within 50 seconds of power-up.

Pager Programming Fields

The system can send various reports to several pagers (VISTA-20P = up to 4; VISTA-15P = up to 2).

To program pager reporting, do the following:

1.Enter the pager phone number(s), preface characters, and pager report options in data fields *160 - *171:

2.Enable Pager Delay, if desired, in field *172 (delays alarm reporting for ALL pagers).

3.Make sure appropriate user open/close pager reports are enabled (see Security Codes, Assigning Attributes in Section 6. System Communication and Operation). Users that perform actions in partition 1 will, if enabled, attempt to report to all pagers enabled for open/close reporting in partition 1. Users that perform actions in partition 2 will, if enabled, attempt to report to all pagers enabled for open/close reporting in partition 2.

4.If using latchkey pager report, define the latchkey report schedule using Scheduling mode (master code + [#] [6] [4] then select event type 03). System must be armed for the Latchkey report to be sent.

5.If using a function key to manually send a message to a pager, use *57 Function Key Menu mode to define the key (function 01).

6.If reporting zone alarms and troubles to a pager, use *81 Zone List menu mode to assign the zones associated with each pager (zone lists 9-12).

VISTA-20P supports four pagers and partitioning; VISTA-15P supports two pagers and zone lists 9 and 10 only.

*160 Pager 1 Phone No.

Enter up to 20 digits.

If entering fewer than 20 digits, exit by pressing [∗] + next field number. To clear entries, press ∗160∗.

4-7

Image 31
Contents Ademco Vista Series Recommendations for Proper Protection Table Of Contents Table Of Contents Capabilities and Functions Features and Installation HighlightsCompatible Devices Important Installation Highlights Installer Please ReadDevice Installing the Control Cabinet and PC Board Mounting and Wiring the ControlAuxiliary Device Current Draw Worksheet Wire Run Chart AC Power, Battery, and Ground ConnectionsSupervised output Connecting the Keypads and Other Addressable DevicesSounder Bell Connections Basic ConnectionsSize MA or less 100 mA 300 mA 500 mA 600 mA Table of Device AddressesKeypad Notes Long Range Radio ConnectionsHardwire Zones and Zone Expansion Zones Smoke Detector NotesReceiver Connections Installing the RF Receiver and Wireless Transmitter ZonesCompatible Receivers RF Receiver No. of ZonesModule Installing a 5800TMInstalling Transmitter Battery LifeKeyswitch Connections Installing a Keyswitch4204/4229 Relay Modules Powerline Carrier DevicesWith the control as shown below On-Board TriggersPhone Line 4285/4286 Phone Module Phone Module ProblemsBank Audio Alarm Verification Connections AAV, listen-InAbout Programming Programming OverviewMechanics of Programming Zone Type Definitions Auxiliary Alarm Alarm by NightHr Silent Alarm AlarmResponse Type No AlarmKeyswitch ConfigurableZone Sounds & Timing ∗31-∗39 System Setup Fields ∗20 ∗29Data Field Programming About Data Field ProgrammingDialer Programming ∗40 ∗50 Zone Programming Menu Mode Burglary Dialer DelayDynamic Signaling Delay Dynamic Signaling PrioritySystem Status Report Codes Miscellaneous System Fields Phone Line Monitor Enable Misc. Fault Delay TimeProgram Mode Lockout Options Event Log EnablesPager Programming Fields Pager 1 Report Options 172Pager Delay Option for AlarmsClean Me Option Pager 1 CharactersZone Type 90 Report Codes Configurable Zone Type FieldsConfigurable Zone Type Configurable Zone Type OptionsZone Conditions Represented Entries Configurable Zone Type ChartsKeypad Programming Fields Touch Screen Keypad AUI EnableInstallation and Setup Guide About Zone Programming ∗56 and ∗58 Menu Modes Menu Mode ProgrammingZone Programming Procedure Zones and PartitionsZone Type ZT Hardwire TypeZone Number Summary ScreenEnroll Summary Input Device typeSerial number Entry and Loop Number Entry Loop Number ChangeCompleting Zone Programming ∗58 Expert Programming Mode ProceduresConfirm Zone ProgrammingSerial number To Delete a Serial NumberPartition Wireless Key Programming TemplatesTemplate Number Template DisplayNot Confirmed Wireless Key Predefined Default TemplatesWireless Key Transmitter 5804BD 2-Way Wireless Key TransmitterOutput Identification About Output Device Programming *79/*80 Menu ModeMenu Mode Output Device Mapping Programming Output DevicesRelay Position Output TypeModule Addresses Output Function No Menu Mode Defining Output FunctionsActivated By = Stay Closed Output Action01-08 = zone list ∗ to continue = off = Change Device State = Close for 2 secondsZone List Programming About Zone Lists *81 Menu ModePartition Numbe About Function Keys *57 Menu ModeProgramming Function Keys Function KeyProgramming Zone Descriptors Menu Mode ∗82 About Descriptor Programming *82 Menu ModeAssigning Partition/Custom Message Descriptors Accept First WordSecond 3-Digit Index No Accept Second WordFor Entering Zone Descriptors Character Ascii Chart For Adding Custom WordsSchedule Number Programming Installer and User SchedulesStart Time = repeat every third week 4 = repeat every fourth week Repeat OptionRandomize For events 01 Digit System Communication and OperationPanel Communication with Central Station Report Code FormatsCode for Type +1/4+1 Report Standard Expanded WhereSome event codes may not apply to certain control panels Ademco Contact IDCode Definition Level User No Functions Keyfob must be enrolled in system first see Wireless KeySystem Security Codes Attributes ValuesFunction Description Keypad CommandsKeypad Functions Voice KeypadsKeys Displayed as Zone ∗ /1 ∗ /# Setting the Real-Time ClockAlpha Display Fixed Disp Meaning Various System Trouble DisplaysInstallation and Setup Guide System Test Testing the SystemAbout Test Procedures Checking Transmitter Enrollment Sniffer ModeAutomatic Periodic Test Report Go/No Go Test ModeAutomatic Standby Battery Tests Dialer Communication Test and Periodic Test ReportsCommunication Specifications & AccessoriesSecurity Control ElectricalDetector Type Wire Smoke DetectorCompatible 5800 Series Transmitters Table Series Transmitter Input Loop IdentificationModel Product Input Type Description Can be used to turn the burglary protection on and off 5827 Wireless KeypadTo be transmitted Industrie Canada Regulatory Agency StatementsUL Notices Page Installation and Setup Guide Page Installation and Setup Guide Limitations of this Alarm System Limitations and Warranty10-8 Index 10-10 Summary of Connections K5305-1V5 10/04 Rev. a Limited Warranty