Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA, K5305-1V5 Summary of Connections

Page 79

10-11

Figure 17. Summary of Connections

24-HR BATTERY STANDBY REQUIRED FOR

BATTERY FUSE

 

 

 

8-PIN CONNECTOR

 

 

 

 

 

 

ADEMCO No. 4219

 

 

 

 

 

 

 

 

 

 

4-WIRE SMOKE DETECTOR CONNECTIONS

 

 

 

USED FOR 1361X10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRE INSTALLATIONS. USE 12V, 17.2AH

 

3A FOR REPLACEMENT,

 

 

 

 

 

 

 

 

WIRED EXPANSION MODULE

 

 

 

 

 

+ 5

 

 

 

 

 

 

BATTERY FOR 600mA AUX POWER. SEE

 

 

 

TRANSFORMER

 

 

 

 

OPTIONAL ADDITIONAL40TOUPFOR ZONES OREITHERFROM( BOTH GROUPS)

 

 

(8 ADD'L EOLR WIRED ZONES)

 

 

 

 

 

 

 

 

 

 

 

 

 

USE SAME VALUE

 

17OUTPUT

 

 

 

 

 

 

 

SET UNIT’S

 

AUX PWR

 

 

 

RELAY

 

 

 

 

 

 

 

 

 

 

 

1)(TRIG.

AUX+12 GND 18OUTPUT 2)(TRIG.

 

 

 

 

 

 

 

-AND/OR-

 

 

 

 

 

 

 

 

 

 

 

INSTRUCTIONS.

 

 

(e.g. ADEMCO No. 90-12)

 

CONNECTIONS AND FOR

 

 

 

 

 

 

 

 

 

 

DIP SWITCH

 

OUTPUT

PROGRAM RELAY

 

BLK

+

RED

BATTERY CAPACITY FOR EMERGENCY

 

 

 

 

 

 

ON-BOARD TRIGGERS

 

 

 

 

 

 

ADEMCO No. 4229

 

 

FOR DEVICE

TERMINALS

AS ZONE TYPE 54

 

 

 

 

BURGLARY STANDBY USE AT LEAST 4 HRS

 

 

 

 

 

SEE INSTRUCTIONS.

(USE SA4120XM-1

 

BLK

(8 ADD'L EOLR WIRED ZONES PLUS 2

 

7 - 15

 

 

 

4

 

 

 

 

 

POWER

 

 

ñ

 

 

 

 

 

1 2

3 4

5

6

7 8

 

RED

 

 

OUTPUT RELAYS)

 

 

SEE

 

 

 

 

 

 

N.C.

 

N.O.

SUPERVISION

CHARGING VOLTAGE

BATTERY

 

BLACK

 

FLYING LEADS

 

 

 

 

 

SYNC

 

 

 

GRN

ADEMCO No. 4204 RELAY MODULE

 

 

 

 

 

UPON FIRE ALARM RESET

 

 

USE N.O.

13.8VDC. MAXIMUM

12V, 4AH

+

+

ñ

 

 

 

 

 

 

COM

TO

 

 

YEL

 

(4 OUTPUT RELAYS)

 

 

 

 

 

 

 

 

 

 

 

VIOLET

CONTACT,

CHARGING CURRENT

 

 

RED

 

FOR BATTERY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO OUTPUT 17

+

 

WHICH CLOSES

 

 

 

 

 

 

 

 

 

 

TRANS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHEN POWER

 

 

 

 

CONNECTION

 

 

 

 

 

 

DATA

 

 

 

 

AND/OR

 

 

 

SET

 

 

 

PROGRAM OUTPUT 17 FOR

 

 

650mA.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"OUT NORM LOW" = YES IN

4-WIRE SMOKE

 

IS APPLIED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADEMCO 5881* Type

 

 

RECEIVER’S

 

79 MENU MODE AND AS ZONE

OR COMBUSTION

2000

 

SEALED LEAD-ACID TYPE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RF RECEIVER

 

 

DIP SWITCH

 

TYPE 54 IN 80 MENU MODE

DETECTOR

OHMS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BLK

 

 

 

 

FOR DEVICE

 

 

MAX. CURRENT = 100 mA

 

 

EOLR

 

BATTERY NORMALLY NEED NOT BE

 

 

 

 

 

 

 

 

 

 

 

TO TERM 4

 

BLK

 

 

 

WIRELESS ZONES

 

 

ADDRESS

 

 

 

(UP TO 16 DETECTORS

 

 

 

 

REPLACED FOR AT LEAST 3 YRS.

 

 

 

 

 

 

 

 

 

 

 

 

 

RED

 

 

 

 

 

 

 

 

 

 

PLUS EOL MODULE)

 

 

 

 

 

 

 

 

RED JUMPER

 

 

 

 

 

TO TERM 5

 

RED

 

 

5881L:

UP TO 8

 

 

 

OF “0”.

 

 

TO ZONE TERM. (+)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GRN

 

 

 

 

SEE

 

 

 

HEAT

 

 

 

TO DETERMINE TOTAL STANDBY LOAD

 

 

 

 

 

ñ

+

 

 

TO TERM 6

 

GRN

 

 

5881M: UP TO 16

 

 

 

INSTRUCTIONS.

 

(ZONES 2 - 8 ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5881H: UP TO 56

 

 

 

 

 

 

 

DETECTOR

 

 

 

 

 

 

CUT FOR BELL SUPERVISION.

 

 

 

YEL

 

 

 

 

 

TO ZONE TERM. ( )

 

 

 

ON BATTERY, ADD 100mA TO TOTAL OF

 

 

 

ALSO, CONNECT 2000 OHM

 

TO TERM 7

 

YEL

 

 

*5882 IN CANADA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUX. POWER OUTPUT AND REMOTE

 

 

 

 

RESISTOR DIRECTLY ACROSS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEYPAD CURRENTS.

 

 

 

 

 

SOUNDER.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USE UL LISTED LIMITED ENERGY

 

1

2

 

3

4

 

 

 

5

 

6

7

8

9

10

11

12

13

14

15

16

 

17

18

 

19

20

 

21

22

23

24

25

CABLE FOR ALL CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLASS 2 PLUG-IN TRANSFORMER

 

 

 

 

 

RETURN)-(

 

}

 

 

 

 

HI

LO

LO

HI

HI

LO

LO

HI

HI

LO

LO

HI

HI

LO

LO

HI

 

}INCOMING}

 

16.5VAC, 25VA

 

 

 

 

 

 

 

 

 

 

 

 

 

(e.g. ADEMCO No. 1321).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TIP

RING

TIP

RING

 

(USE No. 1321CN IN CANADA)

 

USAGE, INCLUDING

 

 

 

 

BLK

PWRKEYPADRED:( + )

KEYPADYELLOW:DATA OUT

SMOKEWIRE-2FORUSED DETECTORS

 

 

 

 

• MAXIMUM LOOP RESISTANCE: (EACH ZONE) 300 OHMS (PLUS EOLR)

 

(BROWN) (GRAY)

(GREEN)

(RED)

 

DESCRIBING PROPER INSTALLATION,

 

 

 

 

INDATAGREEN:FROM KEYPAD

 

 

 

 

 

 

 

 

 

 

USE 1361X10 TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HANDSET

 

 

EARTH

IN ACCORDANCE WITH THE NATIONAL

 

 

 

 

 

GROUNDKEYPAD

AUX. POWER

 

 

 

 

1ZONE

 

2ZONE

 

3ZONE

4ZONE

 

 

5ZONE

6ZONE

7ZONE

 

8ZONE

ONLY20P-VISTA

 

 

DOC LOAD NO.: 3

 

GROUND

INTERFACE IN PLACE OF 1321 OR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHONE LINE

1321CN WHEN POWER LINE CARRIER

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TELEPHONE WIRING

SEE

DEVICES ARE BEING USED. (SEE

 

 

 

 

 

 

10.5-13.8VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(VIA RJ31X* JACK AND DIRECT

INSTRUCTIONS

INSTRUCTIONS FOR CONNECTIONS)

 

TO 110VAC

 

 

 

600mA MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FOR PROPER

 

 

 

UNSWITCHED

 

 

(500mA MAX.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONNECT CORD)

GROUNDING

THIS EQUIPMENT SHOULD BE INSTALLED

OUTLET (24HR)+

 

 

 

FOR UL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*CA38A IN CANADA

 

ñ

INSTALLATIONS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRE PROTECTION ASSOCIATION'S

 

ALARM OUTPUT

BLACK:

ALL OUTPUTS

 

 

 

2000

2000

 

2000

2000

 

2000

2000

2000

2000

 

 

 

 

 

 

STANDARD 72, CHAPTER 2 (NATIONAL

 

ARE POWER

 

 

 

 

 

FOR CONNECTION OF OPTIONAL 4285 OR 4286 VIP

 

 

 

 

 

 

LIMITED.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIRE PROTECTION ASSOCIATION,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODULES TO PHONE TERMINALS, SEE INSTRUCTIONS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BATTERY-MARCH PARK, QUINCY,MA

 

10.5–13.8VDC, 2A MAX.

 

 

 

 

 

 

 

 

OHMS

OHMS

 

OHMS

OHMS

OHMS

OHMS

OHMS

OHMS

WARNING:TO PREVENT RISK OF SHOCK,

02269).

 

 

 

 

 

 

 

 

 

 

 

PRINTED INFORMATION

 

 

(600mA MAX. FOR UL

NOTE:

 

 

 

 

 

 

 

EOLR

EOLR

 

EOLR

EOLR

EOLR

EOLR

EOLR

EOLR

DISCONNECT TELEPHONE LINE AT TELCO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPERATION,TESTING, MAINTENANCE,

 

AUX POWER) STEADY

KEYPAD (S)

 

 

REMOTE

 

BE

 

 

 

 

• RESPONSE, ZONES 1-8:10, 350, OR 700 MSEC (PROGRAMMABLE)

JACK BEFORE SERVICING THIS UNIT.

 

CURRENT (IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

KEYPADS

 

12

13

14

 

 

 

 

 

 

 

EVACUATION PLANNING AND REPAIR

 

FOR BURGLARY/PANIC,

BOTH

 

 

 

 

 

CAN

 

MAXIMUM NUMBER OF 2-WIRE SMOKE DETECTORS ON ZONE 1 IS 16;

 

COMPLIES WITH FCC RULES, PART 68.

 

 

 

 

 

 

 

 

 

 

 

SERVICE IS TO BE PROVIDED WITH THIS

 

TEMPORAL PULSE

 

 

 

 

AND OTHER

 

 

 

 

DETECTORS MUST HAVE COMPATIBILITY IDENTIFIER AS "A".

 

 

FCC REGISTRATION NO. 5GBUSA-44003-AL-E

 

PARTITIONS)

 

 

 

 

 

 

 

 

EQUIPMENT.

 

 

SOUNDING FOR FIRE.

 

ADDRESSABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RINGER EQUIVALENCE: 0.1B.

 

 

 

AND ALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAN USE ADEMCO No. 702

 

 

 

DEVICES

 

 

 

 

 

 

 

 

 

 

 

 

POWER SHUTDOWN NOTE:

 

 

 

 

 

 

 

 

OTHER DEVICES

 

 

 

2k

TAMPER

2k

 

 

 

 

 

ZONE

 

 

 

 

 

 

 

CONNECTION OF THE FIRE ALARM

 

SIREN, OR 12V BELL).

 

(e.g. 5800TM,

 

 

 

 

 

 

 

THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES.

 

DRAWING

 

 

 

 

CONTACTS

 

 

 

 

 

PAIRS

 

SYSTEM SHUTS DOWN SENSOR

SIGNAL TO A FIRE ALARM

 

 

SEE INSTRUCTIONS.

 

 

4285/4286, LRR,

 

 

 

 

 

10

 

11

 

OPERATION IS SUBJECT TO THE FOLLOWING TWO

 

 

POWER FROM

 

 

 

 

 

 

 

 

 

DETECTION PROCESSING IF

HEADQUARTERS OR A CENTRAL STATION

 

 

 

 

 

 

 

2 / 10

 

 

 

 

 

TERMS 4 & 5

 

 

4219, 4229,

 

 

 

 

 

 

 

 

 

 

 

CONTROL'S VOLTAGE DROPS

CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL

SHALL BE PERMITTED ONLY WITH THE

 

 

 

 

 

 

 

4204, 5881)

 

 

 

 

 

 

 

 

 

 

3 / 11

 

INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY

PERMISSION OF THE LOCAL AUTHORITY

 

 

 

 

 

MUST BE

 

 

 

 

 

 

 

 

 

 

ZONE 2

 

 

4 / 12

 

BELOW 9.6V.

 

 

 

INTERFERENCE RECEIVED, INCLUDING INTERFERENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HAVING JURISDICTION. THE BURGLAR

 

 

 

 

 

INCLUDED IN

 

REMOTE KEYPADS

 

2k

TAMPER

2k

 

 

 

 

 

5 / 13

 

 

 

 

 

 

THAT MAY CAUSE UNDESIRED OPERATION.

 

FOR COMPLETE

 

 

 

 

CONTACTS

 

 

 

 

3k

 

6 / 14

 

 

 

 

 

 

ALARM SIGNAL SHALL NOT BE

 

 

AUX CURRENT

 

CAN USE 6150 OR 6160

 

 

 

 

 

 

 

 

7 / 15

 

 

 

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS

CONNECTED TO A POLICE EMERGENCY

 

INFORMATION, SEE

DRAIN

 

 

 

KEYPADS. LOCAL

 

 

 

 

 

 

 

 

 

8 / 16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SYSTEM. IN ADDITION, THIS SYSTEM MUST BE CHECKED BY A QUALIFIED

 

INSTRUCTIONS K5305-1V2

 

 

 

 

 

 

 

 

 

ZONE 10

 

 

 

 

 

NUMBER.

 

 

CALCULATIONS.

PROGRAMMING

 

 

2k

2k

 

 

 

 

 

 

 

 

TECHNICIAN AT LEAST ONCE EVERY THREE (3) YEARS.

 

 

 

 

 

 

 

 

 

 

 

 

MUST BE DONE WITH A

 

 

 

 

6.2k

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE 3

ZONE 4

 

 

 

 

 

 

ALL DEVICES AND ACCESSORIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6139/6160, BUT NEED NOT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TYPICAL WIRING FOR

 

 

TYPICAL WIRING FOR

USED IN A CANADIAN INSTALLATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REMAIN IN THE SYSTEM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOUBLE BALANCED ZONE

 

 

ZONE DOUBLING

 

MUST BE LISTED FOR USE IN CANADA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(SET TO ADDRESS 16).

 

(VISTA-20P ONLY)

 

 

(VISTA-20P ONLY)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ADEMCO VISTA-20P / VISTA-20PSIA SERIES / VISTA-15P / VISTA-15PSIA SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUMMARY OF CONNECTIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V20P_V15P-SOC-V5

Image 79
Contents Ademco Vista Series Recommendations for Proper Protection Table Of Contents Table Of Contents Capabilities and Functions Features and Installation HighlightsCompatible Devices Important Installation Highlights Installer Please ReadDevice Installing the Control Cabinet and PC Board Mounting and Wiring the ControlAuxiliary Device Current Draw Worksheet Wire Run Chart AC Power, Battery, and Ground ConnectionsSupervised output Connecting the Keypads and Other Addressable DevicesSounder Bell Connections Basic ConnectionsSize MA or less 100 mA 300 mA 500 mA 600 mA Table of Device AddressesKeypad Notes Long Range Radio ConnectionsHardwire Zones and Zone Expansion Zones Smoke Detector NotesReceiver Connections Installing the RF Receiver and Wireless Transmitter ZonesCompatible Receivers RF Receiver No. of ZonesModule Installing a 5800TMInstalling Transmitter Battery LifeKeyswitch Connections Installing a Keyswitch4204/4229 Relay Modules Powerline Carrier DevicesWith the control as shown below On-Board TriggersPhone Line 4285/4286 Phone Module Phone Module ProblemsBank Audio Alarm Verification Connections AAV, listen-InAbout Programming Programming OverviewMechanics of Programming Zone Type Definitions Auxiliary Alarm Alarm by NightHr Silent Alarm AlarmResponse Type No AlarmKeyswitch ConfigurableZone Sounds & Timing ∗31-∗39 System Setup Fields ∗20 ∗29Data Field Programming About Data Field ProgrammingDialer Programming ∗40 ∗50 Zone Programming Menu Mode Burglary Dialer DelayDynamic Signaling Delay Dynamic Signaling PrioritySystem Status Report Codes Miscellaneous System Fields Phone Line Monitor Enable Misc. Fault Delay TimeProgram Mode Lockout Options Event Log EnablesPager Programming Fields Pager 1 Report Options 172Pager Delay Option for AlarmsClean Me Option Pager 1 CharactersZone Type 90 Report Codes Configurable Zone Type FieldsConfigurable Zone Type Configurable Zone Type OptionsZone Conditions Represented Entries Configurable Zone Type ChartsKeypad Programming Fields Touch Screen Keypad AUI EnableInstallation and Setup Guide About Zone Programming ∗56 and ∗58 Menu Modes Menu Mode ProgrammingZone Programming Procedure Zones and PartitionsZone Type ZT Hardwire TypeZone Number Summary ScreenEnroll Summary Input Device typeSerial number Entry and Loop Number Entry Loop Number ChangeCompleting Zone Programming ∗58 Expert Programming Mode ProceduresConfirm Zone ProgrammingSerial number To Delete a Serial NumberPartition Wireless Key Programming TemplatesTemplate Number Template DisplayNot Confirmed Wireless Key Predefined Default TemplatesWireless Key Transmitter 5804BD 2-Way Wireless Key TransmitterOutput Identification About Output Device Programming *79/*80 Menu ModeMenu Mode Output Device Mapping Programming Output DevicesRelay Position Output TypeModule Addresses Output Function No Menu Mode Defining Output FunctionsActivated By = Stay Closed Output Action01-08 = zone list ∗ to continue = off = Change Device State = Close for 2 secondsZone List Programming About Zone Lists *81 Menu ModePartition Numbe About Function Keys *57 Menu ModeProgramming Function Keys Function KeyProgramming Zone Descriptors Menu Mode ∗82 About Descriptor Programming *82 Menu ModeAssigning Partition/Custom Message Descriptors Accept First WordSecond 3-Digit Index No Accept Second WordFor Entering Zone Descriptors Character Ascii Chart For Adding Custom WordsSchedule Number Programming Installer and User SchedulesStart Time = repeat every third week 4 = repeat every fourth week Repeat OptionRandomize For events 01 Digit System Communication and OperationPanel Communication with Central Station Report Code FormatsCode for Type +1/4+1 Report Standard Expanded WhereSome event codes may not apply to certain control panels Ademco Contact IDCode Definition Level User No Functions Keyfob must be enrolled in system first see Wireless KeySystem Security Codes Attributes ValuesFunction Description Keypad CommandsKeypad Functions Voice KeypadsKeys Displayed as Zone ∗ /1 ∗ /# Setting the Real-Time ClockAlpha Display Fixed Disp Meaning Various System Trouble DisplaysInstallation and Setup Guide System Test Testing the SystemAbout Test Procedures Checking Transmitter Enrollment Sniffer ModeAutomatic Periodic Test Report Go/No Go Test ModeAutomatic Standby Battery Tests Dialer Communication Test and Periodic Test ReportsCommunication Specifications & AccessoriesSecurity Control ElectricalDetector Type Wire Smoke DetectorCompatible 5800 Series Transmitters Table Series Transmitter Input Loop IdentificationModel Product Input Type Description Can be used to turn the burglary protection on and off 5827 Wireless KeypadTo be transmitted Industrie Canada Regulatory Agency StatementsUL Notices Page Installation and Setup Guide Page Installation and Setup Guide Limitations of this Alarm System Limitations and Warranty10-8 Index 10-10 Summary of Connections K5305-1V5 10/04 Rev. a Limited Warranty