Honeywell VISTA 20P, VISTA-20PSIA, VISTA-15P, VISTA-15PSIA Features and Installation Highlights

Page 5

S E C T I O N 1

Features and Installation Highlights

This manual applies to the following Honeywell security systems:

ADEMCO VISTA-20P/ADEMCO VISTA-20PSIA/ADEMCO VISTA-20PCN (collectively referred to as VISTA-20P series), ADEMCO VISTA-15P/ADEMCO VISTA-15PSIA/ADEMCO VISTA-15PCN (collectively referred to as VISTA-15P series)

Features and procedures apply to all, except where differences are noted.

SIA Installations: The VISTA-20PSIA and VISTA-15PSIA are certified SIA-compliant controls that meet SIA specifications for False Alarm Reduction. The other controls described in this manual are not certified as SIA compliant, but can be programmed for False Alarm Reduction. To program for False Alarm Reduction, follow the SIA Guidelines noted in the applicable programming fields.

NOTE: Throughout this manual, device model numbers are ADEMCO model numbers unless otherwise noted.

Capabilities and Functions

Feature/Function

ADEMCO VISTA-20P Series

ADEMCO VISTA-15P Series

Partitions

• 2 partitions, can protect two independent

VISTA-15P is not a partitioned system.

 

areas

 

 

• Common zone option allows either

 

 

partition to arm, while leaving a common

 

 

area (ex. lobby or foyer) disarmed for

 

 

access into the other partition.

 

Zones

Up to 48 protection zones plus 16 keyfob

Up to 32 zones plus 8 keyfob zones (zones

 

zones (zones 49-64) for total of 64 zones:

49-56) for total of 40 zones:

 

• 8 basic hardwired zones (zones 1-8) with

• 6 basic hardwired zones (zone 1-6)

 

optional zone-doubling feature

• Up to 16 additional wired zones (zones 9-

 

• Up to 40 additional wired zones (zones 9-

24) using up to 2 4219/4229 modules

 

48) using up to 5 4219/4229 modules

• Up to 26 wireless transmitter zones

 

• Up to 40 wireless transmitter zones (5800

(5800 series; zones 9-34)

 

series; zones 9-48)

• Up to 2 configurable zone types

 

• Up to 4 configurable zone types

 

Security Codes

Up to 48 Security Codes, with separate

Up to 32 Security Codes, with separate

 

authority levels and partition access

authority levels

One-button arming

Dedicated keys can arm the system.

Dedicated keys can arm the system.

Schedules

Up to 32; can control devices and/or auto-

Up to 8; can control devices and/or auto-

 

arm/disarm

arm/disarm

Keypad macros

Up to 4; activated by wired keypads

Up to 2; activated by wired keypads

Paging

Up to 4 pagers; certain system conditions

Up to 2 pagers; certain system conditions

 

can report to pagers; can use a dedicated

can report to pagers; can use a dedicated

 

key on keypads to send a signal to a pager

key on keypads to send a signal to a pager

Event Logging

100 events; log display is done via Ademco

50 events; log display is done via Ademco

 

Compass Downloader software or

Compass Downloader software or

 

installer/master code at Keypad

installer/master code at Keypad

Zone descriptors

Can assign for all zones (for alpha display keypads and/or 4285/4286 Phone Module).

Bell supervision

Optional, detects external sounder wiring short or open; causes a trouble condition,

 

keypad display, and sends a report to the central monitoring station, if enabled.

RF jam detection

Optional, for wireless systems detects a condition that may impede proper RF reception

 

(i.e., jamming or other RF interference); causes keypad display, and sends a report to the

 

central monitoring station (if trouble reporting is enabled).

Telephone Line

Built-in option can monitor the telephone line voltage and can cause a local display, or a

Monitoring

display and trouble/alarm sound

 

Downloading

Via an IBM compatible computer, Compass downloading software, and a compatible

 

HAYES or CIA modem specified by Ademco.

 

1-1

Image 5
Contents Ademco Vista Series Recommendations for Proper Protection Table Of Contents Table Of Contents Capabilities and Functions Features and Installation HighlightsDevice Important Installation Highlights Installer Please ReadCompatible Devices Installing the Control Cabinet and PC Board Mounting and Wiring the ControlAuxiliary Device Current Draw Worksheet Wire Run Chart AC Power, Battery, and Ground ConnectionsSounder Bell Connections Connecting the Keypads and Other Addressable DevicesBasic Connections Supervised outputKeypad Notes Table of Device AddressesLong Range Radio Connections Size MA or less 100 mA 300 mA 500 mA 600 mAHardwire Zones and Zone Expansion Zones Smoke Detector NotesCompatible Receivers Installing the RF Receiver and Wireless Transmitter ZonesRF Receiver No. of Zones Receiver ConnectionsInstalling Installing a 5800TMTransmitter Battery Life ModuleKeyswitch Connections Installing a Keyswitch4204/4229 Relay Modules Powerline Carrier DevicesWith the control as shown below On-Board TriggersPhone Line 4285/4286 Phone Module Phone Module ProblemsBank Audio Alarm Verification Connections AAV, listen-InMechanics of Programming Programming OverviewAbout Programming Zone Type Definitions Hr Silent Alarm Alarm by NightAlarm Auxiliary AlarmKeyswitch No AlarmConfigurable Response TypeData Field Programming System Setup Fields ∗20 ∗29About Data Field Programming Zone Sounds & Timing ∗31-∗39Dialer Programming ∗40 ∗50 Dynamic Signaling Delay Burglary Dialer DelayDynamic Signaling Priority Zone Programming Menu ModeSystem Status Report Codes Miscellaneous System Fields Program Mode Lockout Options Misc. Fault Delay TimeEvent Log Enables Phone Line Monitor EnablePager Programming Fields Clean Me Option 172Pager Delay Option for AlarmsPager 1 Characters Pager 1 Report OptionsConfigurable Zone Type Configurable Zone Type FieldsConfigurable Zone Type Options Zone Type 90 Report CodesZone Conditions Represented Entries Configurable Zone Type ChartsKeypad Programming Fields Touch Screen Keypad AUI EnableInstallation and Setup Guide Zone Programming Procedure Menu Mode ProgrammingZones and Partitions About Zone Programming ∗56 and ∗58 Menu ModesZone Number Hardwire TypeSummary Screen Zone Type ZTSerial number Entry and Loop Number Entry Input Device typeLoop Number Change Enroll SummaryCompleting Zone Programming ∗58 Expert Programming Mode ProceduresSerial number Zone ProgrammingTo Delete a Serial Number ConfirmTemplate Number Wireless Key Programming TemplatesTemplate Display PartitionWireless Key Transmitter Wireless Key Predefined Default Templates5804BD 2-Way Wireless Key Transmitter Not ConfirmedMenu Mode Output Device Mapping About Output Device Programming *79/*80 Menu ModeProgramming Output Devices Output IdentificationModule Addresses Output TypeRelay Position Activated By Menu Mode Defining Output FunctionsOutput Function No 01-08 = zone list ∗ to continue Output Action= off = Change Device State = Close for 2 seconds = Stay ClosedZone List Programming About Zone Lists *81 Menu ModeProgramming Function Keys About Function Keys *57 Menu ModeFunction Key Partition NumbeProgramming Zone Descriptors Menu Mode ∗82 About Descriptor Programming *82 Menu ModeSecond 3-Digit Index No Accept First WordAccept Second Word Assigning Partition/Custom Message DescriptorsFor Entering Zone Descriptors Character Ascii Chart For Adding Custom WordsStart Time Programming Installer and User SchedulesSchedule Number Randomize For events 01 Repeat Option= repeat every third week 4 = repeat every fourth week Panel Communication with Central Station System Communication and OperationReport Code Formats DigitCode for Type +1/4+1 Report Standard Expanded WhereCode Definition Ademco Contact IDSome event codes may not apply to certain control panels System Security Codes Keyfob must be enrolled in system first see Wireless KeyAttributes Values Level User No FunctionsKeypad Functions Keypad CommandsVoice Keypads Function DescriptionKeys Displayed as Zone ∗ /1 ∗ /# Setting the Real-Time ClockAlpha Display Fixed Disp Meaning Various System Trouble DisplaysInstallation and Setup Guide About Test Procedures Testing the SystemChecking Transmitter Enrollment Sniffer Mode System TestAutomatic Standby Battery Tests Go/No Go Test ModeDialer Communication Test and Periodic Test Reports Automatic Periodic Test ReportSecurity Control Specifications & AccessoriesElectrical CommunicationDetector Type Wire Smoke DetectorModel Product Input Type Description Series Transmitter Input Loop IdentificationCompatible 5800 Series Transmitters Table To be transmitted 5827 Wireless KeypadCan be used to turn the burglary protection on and off Industrie Canada Regulatory Agency StatementsUL Notices Page Installation and Setup Guide Page Installation and Setup Guide Limitations of this Alarm System Limitations and Warranty10-8 Index 10-10 Summary of Connections K5305-1V5 10/04 Rev. a Limited Warranty