Menu Mode Programming

 

 

Confirm

 

XMIT TO CONFIRM

 

[] to continue

 

PRESS TO SKIP

 

• If “Yes” was entered at the SET TO CONFIRM? prompt previously (see first prompt

 

 

 

 

following entry into the ∗58 Expert Programming Mode), the display on the left will

 

 

appear. Confirm serial and loop numbers by activating the wireless key.

 

 

IMPORTANT:

 

 

When confirmed, the key is not active for arming/disarming until it is assigned to a user

 

 

number (using the assigning attributes command, attribute “4”). See System Operation

 

 

section for procedure.

 

 

Not Confirmed

 

Entd A022-4063

 

[] to continue

 

Rcvd A022-4064

 

If the serial number transmitted does not match the serial number entered, a display

 

 

 

 

similar to the one shown will appear. If the loop number does not match, it will also be

 

 

displayed.

 

 

If so, activate the button on the wireless key once again. If a match is not obtained (i.e.,

 

 

summary display does not appear), press the [#] key and then enter the correct serial

 

 

number.

 

 

If the serial number transmitted matches the serial number entered, the keypad will beep

 

 

3 times and will return you to the Zone Number prompt to enter the starting zone for the

 

 

next wireless key.

 

 

Or you can return to *58 Menu mode by pressing 00 at the Zone Number prompt.

 

 

NOTE: Following the successful enrollment of each wireless device, remove ONE of the

 

 

serial number labels from the device and affix it in the appropriate column on the ZONE

 

 

PROGRAMMING worksheet of the Programming Form; then enter the other information

 

 

(zone number, zone type, loop number, etc.) relevant to that device.

 

 

Wireless Key Predefined Default Templates

 

 

LOOP 3

YOU MUST

OFF

LOOP 2

PROGRAM

ON

 

THIS BUTTON

 

LOOP 1

LOOP 4

 

ENROLL AS "BR"

5 8 0 4 - 0 0 1 - V 1

5804 Wireless Key Transmitter

Note:

These transmitters are not intended for use in UL installations.

GREEN/YELLOW

 

 

 

LED

 

 

LOOP 2

RED/YELLOW

 

 

LOOP 4

LED

 

 

 

 

(YOU MUST

 

 

 

 

 

 

PROGRAM

 

 

 

THIS BUTTON)

LOOP 3

 

 

 

 

 

 

LOOP 1

• •

•••

••

ENROLL AS "BR"

••

 

 

 

5 8 0 4 B D - 0 0 7 - V 0

5804BD 2-Way Wireless Key

Transmitter

 

For 5804

 

 

 

For 5804BD

 

TEMPLATE 1

Loop

Function

Zone Type

 

TEMPLATE 4

Loop

Function

Zone Type

 

1

No Response

23

 

 

1

No Response

23

 

2

Disarm

22

 

 

2

No Response

23

 

3

Arm Away

21

 

 

3

Arm Away

21

 

4

No Response

23

 

 

4

Disarm

22

TEMPLATE 2

Loop

Function

Zone Type

 

TEMPLATE 5

Loop

Function

Zone Type

 

1

No Response

23

 

 

1

No Response

23

 

2

Disarm

22

 

 

2

Arm Stay

20

 

3

Arm Away

21

 

 

3

Arm Away

21

 

4

Arm Stay

20

 

 

4

Disarm

22

TEMPLATE 3

Loop

Function

Zone Type

 

TEMPLATE 6

Loop

Function

Zone Type

 

1

24-hour audible

7

 

 

1

24-hour audible

7

 

2

Disarm

22

 

 

2

Arm Stay

20

 

3

Arm Away

21

 

 

3

Arm Away

21

 

4

Arm Stay

20

 

 

4

Disarm

22

5-7

Image 43
Contents Ademco Vista Series Recommendations for Proper Protection Table Of Contents Table Of Contents Capabilities and Functions Features and Installation HighlightsCompatible Devices Important Installation Highlights Installer Please ReadDevice Installing the Control Cabinet and PC Board Mounting and Wiring the ControlAuxiliary Device Current Draw Worksheet Wire Run Chart AC Power, Battery, and Ground ConnectionsSupervised output Connecting the Keypads and Other Addressable DevicesSounder Bell Connections Basic ConnectionsSize MA or less 100 mA 300 mA 500 mA 600 mA Table of Device AddressesKeypad Notes Long Range Radio ConnectionsHardwire Zones and Zone Expansion Zones Smoke Detector NotesReceiver Connections Installing the RF Receiver and Wireless Transmitter ZonesCompatible Receivers RF Receiver No. of ZonesModule Installing a 5800TMInstalling Transmitter Battery LifeKeyswitch Connections Installing a Keyswitch4204/4229 Relay Modules Powerline Carrier DevicesWith the control as shown below On-Board TriggersPhone Line 4285/4286 Phone Module Phone Module ProblemsBank Audio Alarm Verification Connections AAV, listen-InAbout Programming Programming OverviewMechanics of Programming Zone Type Definitions Auxiliary Alarm Alarm by NightHr Silent Alarm AlarmResponse Type No AlarmKeyswitch ConfigurableZone Sounds & Timing ∗31-∗39 System Setup Fields ∗20 ∗29Data Field Programming About Data Field ProgrammingDialer Programming ∗40 ∗50 Zone Programming Menu Mode Burglary Dialer DelayDynamic Signaling Delay Dynamic Signaling PrioritySystem Status Report Codes Miscellaneous System Fields Phone Line Monitor Enable Misc. Fault Delay TimeProgram Mode Lockout Options Event Log EnablesPager Programming Fields Pager 1 Report Options 172Pager Delay Option for AlarmsClean Me Option Pager 1 CharactersZone Type 90 Report Codes Configurable Zone Type FieldsConfigurable Zone Type Configurable Zone Type OptionsZone Conditions Represented Entries Configurable Zone Type ChartsKeypad Programming Fields Touch Screen Keypad AUI EnableInstallation and Setup Guide About Zone Programming ∗56 and ∗58 Menu Modes Menu Mode ProgrammingZone Programming Procedure Zones and PartitionsZone Type ZT Hardwire TypeZone Number Summary ScreenEnroll Summary Input Device typeSerial number Entry and Loop Number Entry Loop Number ChangeCompleting Zone Programming ∗58 Expert Programming Mode ProceduresConfirm Zone ProgrammingSerial number To Delete a Serial NumberPartition Wireless Key Programming TemplatesTemplate Number Template DisplayNot Confirmed Wireless Key Predefined Default TemplatesWireless Key Transmitter 5804BD 2-Way Wireless Key TransmitterOutput Identification About Output Device Programming *79/*80 Menu ModeMenu Mode Output Device Mapping Programming Output DevicesRelay Position Output TypeModule Addresses Output Function No Menu Mode Defining Output FunctionsActivated By = Stay Closed Output Action01-08 = zone list ∗ to continue = off = Change Device State = Close for 2 secondsZone List Programming About Zone Lists *81 Menu ModePartition Numbe About Function Keys *57 Menu ModeProgramming Function Keys Function KeyProgramming Zone Descriptors Menu Mode ∗82 About Descriptor Programming *82 Menu ModeAssigning Partition/Custom Message Descriptors Accept First WordSecond 3-Digit Index No Accept Second WordFor Entering Zone Descriptors Character Ascii Chart For Adding Custom WordsSchedule Number Programming Installer and User SchedulesStart Time = repeat every third week 4 = repeat every fourth week Repeat OptionRandomize For events 01 Digit System Communication and OperationPanel Communication with Central Station Report Code FormatsCode for Type +1/4+1 Report Standard Expanded WhereSome event codes may not apply to certain control panels Ademco Contact IDCode Definition Level User No Functions Keyfob must be enrolled in system first see Wireless KeySystem Security Codes Attributes ValuesFunction Description Keypad CommandsKeypad Functions Voice KeypadsKeys Displayed as Zone ∗ /1 ∗ /# Setting the Real-Time ClockAlpha Display Fixed Disp Meaning Various System Trouble DisplaysInstallation and Setup Guide System Test Testing the SystemAbout Test Procedures Checking Transmitter Enrollment Sniffer ModeAutomatic Periodic Test Report Go/No Go Test ModeAutomatic Standby Battery Tests Dialer Communication Test and Periodic Test ReportsCommunication Specifications & AccessoriesSecurity Control ElectricalDetector Type Wire Smoke DetectorCompatible 5800 Series Transmitters Table Series Transmitter Input Loop IdentificationModel Product Input Type Description Can be used to turn the burglary protection on and off 5827 Wireless KeypadTo be transmitted Industrie Canada Regulatory Agency StatementsUL Notices Page Installation and Setup Guide Page Installation and Setup Guide Limitations of this Alarm System Limitations and Warranty10-8 Index 10-10 Summary of Connections K5305-1V5 10/04 Rev. a Limited Warranty