Bosch Appliances MIC612 Powering On, Controlling the Camera, Basic Keyboard Operation, Lcd

Page 31

MIC612 Thermal Camera

Getting Started en 31

 

 

CAUTION!

Bosch recommends that multiple RS-485 connections be arranged as a connected series of point-to-point (multidropped) nodes, as a line or as a bus. It is not recommended to arrange RS-485 connections as a star, ring, or as a multiple-connected network. Star and ring topologies may cause signal reflections or excessively low or high termination impedance.

In Pelco Protocol Mode, the camera is configured from the factory for RS-485 operation.

1.Connect the controller's Tx terminals to the Tx terminals in the power supply box. See the MIC Series Power Supplies Installation Manual for complete wiring instructions.

2.Pan or tilt the keyboard joystick to confirm that control has been established to the camera (approximately five (5) seconds).

5.2

Powering On

 

When you turn on power to the camera, a splash screen or text displays the type of device

 

(MIC612), the camera model, the video type (PAL or NTSC), the firmware version, and (if

 

applicable) the MAC address.

5.3

Controlling the Camera

 

 

The most common ways to control the MIC612 are:

 

 

– Using a keyboard and on-screen display (OSD) menus. This method is the most common.

 

 

See Section 5.3.1 Basic Keyboard Operation, page 31.

 

 

– Using the Configuration Tool for Imaging Devices (CTFID) software running on a PC with

 

 

Bilinx or the RS-232/RS-485 communication protocol. Go to www.boschsecurity.com to

 

 

download the latest version of the software and the CTFID User Manual.

 

 

– Using a PC-based graphical user interface (GUI).

5.3.1

Basic Keyboard Operation

 

 

The following tables summarize the basic operations for a standard keyboard and the

 

 

functions available to control a MIC612 camera.

 

 

 

 

 

 

 

 

 

Typical Keyboard

Usage

 

 

 

Features

 

 

 

 

 

 

Function Keys

Selects a specific control setting.

 

 

 

Number Keys

Inputs a number from 0 to 9.

 

 

 

Camera Key

Selects a camera number.

 

 

 

Enter Key

Inputs a selection.

 

 

 

Focus Key

Sets the lens focus or makes a menu selection in OSD mode.

 

 

 

Iris Key

Sets the lens iris setting or makes a menu selection in OSD mode.

 

 

 

Key LEDs

Indicates an active key.

 

 

 

LCD

Displays the current status.

 

 

 

Joystick

Controls the pan/tilt/zoom (PTZ) functions of the camera.

 

 

 

Table 5.1 Typical Keyboard Functions

 

 

 

 

 

 

 

Camera Operation

Control Method

 

 

 

 

To Pan Side to Side

Move the joystick left or right.

 

 

 

 

To Tilt Up and Down

Move the joystick forward and back.

 

 

 

 

To Zoom In

 

Twist the joystick clockwise.

 

 

 

 

To Zoom Out

 

Twist the joystick counterclockwise.

 

 

Table 5.2 Typical Keyboard Controls for a MIC612 Camera

Bosch Security Systems, Inc.

Installation Manual

F.01U.249.416 2.0 2012.09

Image 31
Contents MIC612 Thermal Camera Page Table of Contents On-Screen Display OSD Menus Pelco Protocol Common User CommandsAdvanced Features On-Screen Display OSD Menus Bosch ProtocolIndex Maintenance and Troubleshooting Keyboard Commands By NumberConventions in this Manual SafetyImportant Safety Instructions About this ManualMIC612 Thermal Camera Safety en Important Notices EC DirectivesCoax grounding FCC ET Ices Information commercial applications FCC and Ices ComplianceInformations FCC ET Ices applications commerciales Bosch Notices Customer Support and ServiceUSA Additional Tools Required Parts List2Unpacking Additional Products RequiredMIC camera mounting positions Upright, Inverted Installation OverviewNumber Description Typical Mounting ArrangementsMounting Positions 3About the MIC Shielded Composite Cable About Alarm Inputs and OutputsAn 8-input alarm card installed in the MIC PSU Alarm Card Number Installed? Alarm Inputs Alarm OutputsTypical Installation Configurations InstallationMIC-BP4 sold separately Example 2 Configuration with RS-485 protocol connection Overview of Installation StepsFollow these steps in sequence to install the MIC612 camera Mounting the Camera Installing the MIC Power Supply Unit PSU Fuse Ratings Earth Link on PCB3Layout of MIC Power Supply Units PSUs for MIC612 Electrical Shock Hazard 4Installation InstructionsNumber Description PCB Marking Description AUX1 Number Description Cable Gland SizeAUX2 MIC612 Thermal Camera Installation en LED Description Power supply. Follow these stepsDisconnect the power supply from the power source Commissioning the Camera with Heater Option FittedScrewdriver Fitting the Optional Sunshield MIC612Bottom half of the sunshield see step Head is facing upEstablishing Control of the Camera via RS-485 Protocol Establishing Control of the Camera via Biphase ProtocolGetting Started Establishing Control of the CameraLCD Powering OnControlling the Camera Basic Keyboard Operation4Keyboard Commands, Pelco Protocol Keyboard Commands, Bosch ProtocolNavigating the On-Screen Display OSD Menus Special Preset Commands, Pelco Protocol 4Setting the Addresses of the Two Cameras of the MIC612Preset FastAddress, Bosch Protocol Setting the Address of the Optical Camera via FastAddressTo set FastAddress with a Pelco Keyboard 3FastAddress, Pelco ProtocolsTo set an address for a camera without an address To change or clear an address for a camera with an addressSpecial Passwords Setting PasswordsConfiguring the Camera for Inverted Operation Active Commands in FastAddress6On-Screen Display OSD Menus Bosch Protocol Setup MenuATW Camera Setup MenuWDR Thermal Camera Setup Menu Manual Lens Setup MenuPTZ Setup Menu Display Setup Menu Compass Display AdjustCamera OSD AzimuthBaud Rate Communication Setup MenuCommunication Setup AutoBaudNone Alarm SetupOSD Outputs Setup SubmenuOutputs Setup Submenu Choices OutputsRule # Choices Enabled Rule Setup SubmenuRule Setup Rule Setup Submenu ChoicesInput Language MenuOutput Bist Diagnostics MenuInternal Humidity Security AccessCtfid Access Power Up EventsTotal Time On Alarm Status SubmenuAlarm Input Alarm OutputOn-Screen Display OSD Menus Pelco Protocol Continuous Camera SetupPelco menu Bosch menu Setup Menu Bosch MenuBalance PTZ SetupWhite OutdoorOFF Other MenusFlat-Field Correction FFC Switching VideoDisplaying Thermal Camera Temperature Operation of the Thermal CameraSet the Alarm Rule Triggering Alarms On Detection of Objects Outside of SetThermal Temperature Threshold Set the Temperature ThresholdSpecifying a Shot or a Sector Title Common User CommandsSetting AutoPan Mode Setting Preset ShotsProgramming the Inactivity Operation Configuring Preposition ToursRecording Tours Using the Wiper/Washer10.1.2 Alarm Rule Examples Advanced Features10.1 Alarm Rules 10.1.1 Controlling Alarm Rules10.2 Privacy Masking Example 2 Advanced Alarm Rule10.5 Azimuth, Elevation, and Compass Directions 10.5.1 Setting the Azimuth Zero Point10.3 Image Stabilization 10.4 Pre-position Tour180 / -45 S 10.5.2 Displaying Azimuth, Elevation, and Compass HeadingsProblem Explanation Solution 11Maintenance and TroubleshootingKeyboard Commands Bosch Protocol Keyboard Commands By NumberCommands, Optical Camera Refer to .5 Azimuth, Elevation, Compass Directions, Zone/Sector Title Menu Enters the Zone Title menu. Refer toCommands, Thermal Camera 70 en MIC612 Thermal Camera Keyboard User Action Description Command Keyboard Commands Pelco ProtocolEn MIC612 Thermal Camera #-ENTER IndexPre-compensation 39 sharpness 38 shutter White balance En Index MIC612 Thermal Camera Constant focus 41 manual focus 41 spot focus PTZ Custom tourZero pan ShotPage Page Bosch Security Systems, Inc

MIC612 specifications

The Bosch Appliances MIC612 is an innovative and highly efficient piece of kitchen equipment that enhances the culinary experience for home chefs and professionals alike. Renowned for its quality, Bosch has developed this compact microwave that combines advanced technology with user-friendly features.

One of the standout characteristics of the MIC612 is its sleek design, seamlessly incorporating into various kitchen styles. With its stainless-steel finish, the microwave not only offers aesthetic appeal but also ensures durability and easy maintenance. Its compact size makes it an ideal fit for smaller kitchens or areas where space is limited, while still providing ample cooking capacity.

The MIC612 is equipped with intelligent cooking technology. This includes sensor cooking, which automatically adjusts cooking time and power levels based on moisture detected in the food. This feature simplifies meal preparation by eliminating the need for constant monitoring, ensuring perfectly cooked dishes every time. Additionally, the microwave offers multiple cooking modes, including reheating, defrosting, and cooking with precision.

For those who appreciate convenience, the MIC612 includes pre-programmed settings for common foods like popcorn, pizza, and baked goods. This allows users to enjoy a wide variety of meals with minimal effort. The intuitive control panel and clear digital display enhance the ease of use, enabling quick selection of settings and cooking times.

Safety is a paramount concern for Bosch, and the MIC612 does not disappoint. It features a child safety lock, ensuring that curious little hands cannot accidentally operate the appliance. Moreover, the design incorporates a reliable cooling system to prevent overheating and ensure longevity.

Energy efficiency is another highlight of the Bosch MIC612. It is designed to consume less power compared to traditional microwaves, making it an eco-friendly choice without compromising performance. The combination of cutting-edge technology, thoughtful design, and practical features makes the Bosch Appliances MIC612 a valuable addition to any kitchen, offering versatility and reliability for all cooking needs. Whether reheating leftovers or preparing a fresh meal from scratch, this microwave stands out as a remarkable option for modern culinary tasks.