Bosch Appliances MIC612 installation manual Constant focus 41 manual focus 41 spot focus

Page 75

MIC612 Thermal Camera

Index en 75

 

 

H

high temperature events 50 threshold 50

I

image stabilization 64 inactivity 42

accessing 60 mode 60 operation 60 period 42

Inactivity Mode menu 60 indoor white balance 38 input commands 46 inputs (1-7) 46

inputs (8-12) 46 inputs setup 46 internal temperature 50 iris speed 41

K

keyboard commands 67, 69

#-ENTER 35

Aux Off 32

Aux On 32 Command key 32 Enter key 32 Function key 32 OFF-90-ENTER 36, 60 ON-997-ENTER 35 ON-998-ENTER 35 ON-999-ENTER 34 ON-9-ENTER 60

Set 59

Set Shot 32 SET-100-ENTER 59 SET-802-ENTER 36 Shot 59

Shot Shot 32

L

Language menu 37, 49 Lens Setup menu 37, 41

auto focus 41

constant focus 41 manual focus 41 spot focus 41

auto iris 41

constant iris 41 manual iris 41

auto iris level 41 digital zoom 41 focus speed 41 iris speed 41 maximum zoom speed 41

limit stops 33, 56 low temperature events 50

threshold 50 low volt events 51

M

manual focus 41 iris 41

masking privacy 44

maximum zoom speed 41 menus

Alarm Setup 46 Bosch 54

Camera Setup 38, 54 Command Lock 53 Communication Setup 45 Diagnostics 50

Display Setup 43

Inactivity Mode 60 Language 49 Lens Setup 41 Other 56

other 56

Outputs Setup 46 Pelco 34

Pelco Setup 33 PTZ Setup 42, 55

Azimuth Zero 43

Setup 54

Tour Period 60

N

networking baud rate 45

night mode 39, 55 color 39 threshold 39

O

OFF-90-ENTER 36, 60 ON-997-ENTER 35 ON-998-ENTER 35 ON-999-ENTER 34 ON-9-ENTER 60 on-screen display 43, 53 OSD 43, 53

outdoor white balance 38 outputs (1-3) 47 outputs (5-12) 47 Outputs Setup menu 46

outputs (1-3) 47 outputs (5-12) 47

P

passwords changing 36 security level 36 special 36

Bosch Security Systems, Inc.

Installation Manual

F.01U.249.416 2.0 2012.09

Image 75
Contents MIC612 Thermal Camera Page Table of Contents On-Screen Display OSD Menus Pelco Protocol Common User CommandsAdvanced Features On-Screen Display OSD Menus Bosch ProtocolIndex Maintenance and Troubleshooting Keyboard Commands By NumberConventions in this Manual SafetyImportant Safety Instructions About this ManualMIC612 Thermal Camera Safety en Important Notices EC DirectivesCoax grounding FCC and Ices Compliance FCC ET Ices Information commercial applicationsInformations FCC ET Ices applications commerciales Customer Support and Service Bosch NoticesUSA Additional Tools Required Parts List2Unpacking Additional Products RequiredMIC camera mounting positions Upright, Inverted Installation OverviewNumber Description Typical Mounting ArrangementsMounting Positions 3About the MIC Shielded Composite Cable About Alarm Inputs and OutputsAn 8-input alarm card installed in the MIC PSU Alarm Card Number Installed? Alarm Inputs Alarm OutputsInstallation Typical Installation ConfigurationsMIC-BP4 sold separately Overview of Installation Steps Example 2 Configuration with RS-485 protocol connectionFollow these steps in sequence to install the MIC612 camera Mounting the Camera Installing the MIC Power Supply Unit PSU Fuse Ratings Earth Link on PCB3Layout of MIC Power Supply Units PSUs for MIC612 Electrical Shock Hazard 4Installation InstructionsNumber Description PCB Marking Description Number Description Cable Gland Size AUX1AUX2 MIC612 Thermal Camera Installation en LED Description Power supply. Follow these stepsDisconnect the power supply from the power source Commissioning the Camera with Heater Option FittedScrewdriver Fitting the Optional Sunshield MIC612Bottom half of the sunshield see step Head is facing upEstablishing Control of the Camera via RS-485 Protocol Establishing Control of the Camera via Biphase ProtocolGetting Started Establishing Control of the CameraLCD Powering OnControlling the Camera Basic Keyboard OperationKeyboard Commands, Bosch Protocol 4Keyboard Commands, Pelco ProtocolNavigating the On-Screen Display OSD Menus 4Setting the Addresses of the Two Cameras of the MIC612 Special Preset Commands, Pelco ProtocolPreset FastAddress, Bosch Protocol Setting the Address of the Optical Camera via FastAddressTo set FastAddress with a Pelco Keyboard 3FastAddress, Pelco ProtocolsTo set an address for a camera without an address To change or clear an address for a camera with an addressSpecial Passwords Setting PasswordsConfiguring the Camera for Inverted Operation Active Commands in FastAddress6On-Screen Display OSD Menus Bosch Protocol Setup MenuATW Camera Setup MenuWDR Thermal Camera Setup Menu Manual Lens Setup MenuPTZ Setup Menu Display Setup Menu Compass Display AdjustCamera OSD AzimuthBaud Rate Communication Setup MenuCommunication Setup AutoBaudNone Alarm SetupOSD Outputs Setup SubmenuOutputs Setup Submenu Choices OutputsRule # Choices Enabled Rule Setup SubmenuRule Setup Rule Setup Submenu ChoicesLanguage Menu InputOutput Bist Diagnostics MenuInternal Humidity Security AccessCtfid Access Power Up EventsTotal Time On Alarm Status SubmenuAlarm Input Alarm OutputOn-Screen Display OSD Menus Pelco Protocol Continuous Camera SetupPelco menu Bosch menu Setup Menu Bosch MenuBalance PTZ SetupWhite OutdoorOFF Other MenusFlat-Field Correction FFC Switching VideoDisplaying Thermal Camera Temperature Operation of the Thermal CameraSet the Alarm Rule Triggering Alarms On Detection of Objects Outside of SetThermal Temperature Threshold Set the Temperature ThresholdSpecifying a Shot or a Sector Title Common User CommandsSetting AutoPan Mode Setting Preset ShotsProgramming the Inactivity Operation Configuring Preposition ToursRecording Tours Using the Wiper/Washer10.1.2 Alarm Rule Examples Advanced Features10.1 Alarm Rules 10.1.1 Controlling Alarm Rules10.2 Privacy Masking Example 2 Advanced Alarm Rule10.5 Azimuth, Elevation, and Compass Directions 10.5.1 Setting the Azimuth Zero Point10.3 Image Stabilization 10.4 Pre-position Tour180 / -45 S 10.5.2 Displaying Azimuth, Elevation, and Compass HeadingsProblem Explanation Solution 11Maintenance and TroubleshootingKeyboard Commands By Number Keyboard Commands Bosch ProtocolCommands, Optical Camera Refer to .5 Azimuth, Elevation, Compass Directions, Zone/Sector Title Menu Enters the Zone Title menu. Refer toCommands, Thermal Camera 70 en MIC612 Thermal Camera Keyboard User Action Description Command Keyboard Commands Pelco ProtocolEn MIC612 Thermal Camera Index #-ENTERPre-compensation 39 sharpness 38 shutter White balance En Index MIC612 Thermal Camera Constant focus 41 manual focus 41 spot focus PTZ Custom tourZero pan ShotPage Page Bosch Security Systems, Inc

MIC612 specifications

The Bosch Appliances MIC612 is an innovative and highly efficient piece of kitchen equipment that enhances the culinary experience for home chefs and professionals alike. Renowned for its quality, Bosch has developed this compact microwave that combines advanced technology with user-friendly features.

One of the standout characteristics of the MIC612 is its sleek design, seamlessly incorporating into various kitchen styles. With its stainless-steel finish, the microwave not only offers aesthetic appeal but also ensures durability and easy maintenance. Its compact size makes it an ideal fit for smaller kitchens or areas where space is limited, while still providing ample cooking capacity.

The MIC612 is equipped with intelligent cooking technology. This includes sensor cooking, which automatically adjusts cooking time and power levels based on moisture detected in the food. This feature simplifies meal preparation by eliminating the need for constant monitoring, ensuring perfectly cooked dishes every time. Additionally, the microwave offers multiple cooking modes, including reheating, defrosting, and cooking with precision.

For those who appreciate convenience, the MIC612 includes pre-programmed settings for common foods like popcorn, pizza, and baked goods. This allows users to enjoy a wide variety of meals with minimal effort. The intuitive control panel and clear digital display enhance the ease of use, enabling quick selection of settings and cooking times.

Safety is a paramount concern for Bosch, and the MIC612 does not disappoint. It features a child safety lock, ensuring that curious little hands cannot accidentally operate the appliance. Moreover, the design incorporates a reliable cooling system to prevent overheating and ensure longevity.

Energy efficiency is another highlight of the Bosch MIC612. It is designed to consume less power compared to traditional microwaves, making it an eco-friendly choice without compromising performance. The combination of cutting-edge technology, thoughtful design, and practical features makes the Bosch Appliances MIC612 a valuable addition to any kitchen, offering versatility and reliability for all cooking needs. Whether reheating leftovers or preparing a fresh meal from scratch, this microwave stands out as a remarkable option for modern culinary tasks.