Bosch Appliances MIC612 installation manual Commands, Thermal Camera

Page 69

MIC612 Thermal Camera

 

en 69

 

 

 

 

 

 

 

 

 

 

 

 

 

Locked

Function

Command

Command

Description

 

 

Key

No.

 

 

 

 

On

99

Factory P/T Home Position

Recalibrates home position; can be used as an

 

 

 

 

 

Alarm Output.

 

 

 

 

 

 

 

 

On/Off

100

Record A

Activates/deactivates recording A.

 

 

On/Off

101

Record B

Activates/deactivates recording B.

 

 

On/Off

102

Wiper continuous

Turns on/off continous wiper mode.

 

 

On/Off

103

Wiper intermittent

Activates the wiper in Intermittent mode (the

 

 

 

 

 

wiper wipes twice, then turns off after 15

 

 

 

 

 

seconds).

 

 

 

 

 

 

 

 

On/Off

104

Wiper one shot

Activates (One shot) to wipe five times, then turn

 

 

 

 

 

off.

 

 

 

 

 

 

 

 

On/Off

105

Wash/Wipe

Activates wash/wip mode. Cameras moves to

 

 

 

 

 

designated washer preset (62), wiper starts

 

 

 

 

 

automatically.

 

 

On

997

FastAddress, display

Display the current FastAddress of the camera.

 

 

On

998

FastAddress, all units

Displays the current FastAddress of the camera

 

 

 

 

 

and programs all units.

 

 

On

999

FastAddress, unaddressed cameras

Displays and programs unaddressed MIC612

 

 

 

 

 

units.

 

 

 

 

 

 

 

 

Set

“1-99”

Pre-position Programming

Set ##–Programs a preset view.

 

 

Shot

“1-99”

Pre-position Recall

Shot ##–Recall programmed preset.

 

 

Set

100

Pre-position Menu

Enters the Pre-position menu.

 

 

Set/Shot

101

Autopan Left Limit

Set–Programs left limit.

 

 

 

 

 

Shot–Shows limit.

 

 

 

 

 

 

 

 

Set/Shot

102

Autopan Right Limit

Set–Programs right limit.

 

 

 

 

 

Shot–Shows limit.

 

 

 

 

 

 

 

 

Set

110

Factory P/T Home Position

Set–Recalibrate home position.

 

*

Set

802

Edit Password

Enters the Edit Password menu.

 

*

Set

899

Reset ALL

Restores all settings to original defaults and

 

 

 

 

 

clears all user-programmed settings.

 

 

 

 

 

 

 

 

Set

900

Edit Tour 1 (Standard)

Enters the Standard Tour Scene menu.

 

 

Shot

900

Edit Tour 2 (Custom)

Enters the Custom Tour Scene menu.

 

 

Set/Shot

901-999

Adds/Removes a Preposition Shot

Set ###–Adds preset.

 

 

 

 

from Tour 1

Shot ###–Removes preset.

 

A.1.2

 

Commands, Thermal Camera

 

 

 

 

 

 

 

 

Locked

Function

Command

Command

Description

 

 

Key

No.

 

 

 

 

On/Off

1

Scan 360°

Autopan without limits.

 

 

On/Off

2

Autopan

Autopan between limits.

 

 

On/Off

7

Play Custom Pre-position Tour

Activates/Deactivates the playback of a custom,

 

 

 

 

 

pre-position tour.

 

 

On/Off

8

Play Pre-position Tour

Activates/Deactivates the playback of a pre-

 

 

 

 

 

position tour.

 

*

On/Off

18

AutoPivot Enable

Enables/disables AutoPivot.

 

 

On/Off

50

Playback A, continuous

Activates/Deactivates continuous playback A.

 

 

On/Off

51

Playback A, single

Activates/Deactivates single playback A.

 

 

On/Off

52

Playback B, continuous

Activates/Deactivates continuous playback B.

 

 

On/Off

53

Playback B, single

Activates/Deactivates single playback B.

 

*

On/Off

69

Alarm Rule Activation/Deactivation

On–Enables all alarm rules.

 

 

 

 

 

Off–Disables all alarm rules.

 

 

 

 

 

 

 

*

On/Off

80

Digital Zoom Lock

Turns digital zoom on and off.

 

Bosch Security Systems, Inc.

Installation Manual

F.01U.249.416 2.0 2012.09

Image 69
Contents MIC612 Thermal Camera Page Table of Contents Advanced Features Common User CommandsOn-Screen Display OSD Menus Bosch Protocol On-Screen Display OSD Menus Pelco ProtocolIndex Maintenance and Troubleshooting Keyboard Commands By NumberImportant Safety Instructions SafetyAbout this Manual Conventions in this ManualMIC612 Thermal Camera Safety en Important Notices EC DirectivesCoax grounding FCC and Ices Compliance FCC ET Ices Information commercial applicationsInformations FCC ET Ices applications commerciales Customer Support and Service Bosch NoticesUSA 2Unpacking Parts ListAdditional Products Required Additional Tools RequiredMIC camera mounting positions Upright, Inverted Installation OverviewNumber Description Typical Mounting ArrangementsMounting Positions An 8-input alarm card installed in the MIC PSU About Alarm Inputs and OutputsAlarm Card Number Installed? Alarm Inputs Alarm Outputs 3About the MIC Shielded Composite CableInstallation Typical Installation ConfigurationsMIC-BP4 sold separately Overview of Installation Steps Example 2 Configuration with RS-485 protocol connectionFollow these steps in sequence to install the MIC612 camera Mounting the Camera Installing the MIC Power Supply Unit PSU Fuse Ratings Earth Link on PCB3Layout of MIC Power Supply Units PSUs for MIC612 Electrical Shock Hazard 4Installation InstructionsNumber Description PCB Marking Description Number Description Cable Gland Size AUX1AUX2 MIC612 Thermal Camera Installation en Disconnect the power supply from the power source Power supply. Follow these stepsCommissioning the Camera with Heater Option Fitted LED DescriptionBottom half of the sunshield see step Fitting the Optional Sunshield MIC612Head is facing up ScrewdriverGetting Started Establishing Control of the Camera via Biphase ProtocolEstablishing Control of the Camera Establishing Control of the Camera via RS-485 ProtocolControlling the Camera Powering OnBasic Keyboard Operation LCDKeyboard Commands, Bosch Protocol 4Keyboard Commands, Pelco ProtocolNavigating the On-Screen Display OSD Menus 4Setting the Addresses of the Two Cameras of the MIC612 Special Preset Commands, Pelco ProtocolPreset FastAddress, Bosch Protocol Setting the Address of the Optical Camera via FastAddressTo set an address for a camera without an address 3FastAddress, Pelco ProtocolsTo change or clear an address for a camera with an address To set FastAddress with a Pelco KeyboardConfiguring the Camera for Inverted Operation Setting PasswordsActive Commands in FastAddress Special Passwords6On-Screen Display OSD Menus Bosch Protocol Setup MenuATW Camera Setup MenuWDR Thermal Camera Setup Menu Manual Lens Setup MenuPTZ Setup Menu Display Setup Menu Camera OSD Display AdjustAzimuth CompassCommunication Setup Communication Setup MenuAutoBaud Baud RateNone Alarm SetupOutputs Setup Submenu Choices Outputs Setup SubmenuOutputs OSDRule Setup Rule Setup SubmenuRule Setup Submenu Choices Rule # Choices EnabledLanguage Menu InputOutput Bist Diagnostics MenuCtfid Access Security AccessPower Up Events Internal HumidityAlarm Input Alarm Status SubmenuAlarm Output Total Time OnOn-Screen Display OSD Menus Pelco Protocol Pelco menu Bosch menu Setup Menu Camera SetupBosch Menu ContinuousWhite PTZ SetupOutdoor BalanceOFF Other MenusDisplaying Thermal Camera Temperature Switching VideoOperation of the Thermal Camera Flat-Field Correction FFCThermal Temperature Threshold Triggering Alarms On Detection of Objects Outside of SetSet the Temperature Threshold Set the Alarm RuleSetting AutoPan Mode Common User CommandsSetting Preset Shots Specifying a Shot or a Sector TitleProgramming the Inactivity Operation Configuring Preposition ToursRecording Tours Using the Wiper/Washer10.1 Alarm Rules Advanced Features10.1.1 Controlling Alarm Rules 10.1.2 Alarm Rule Examples10.2 Privacy Masking Example 2 Advanced Alarm Rule10.3 Image Stabilization 10.5.1 Setting the Azimuth Zero Point10.4 Pre-position Tour 10.5 Azimuth, Elevation, and Compass Directions180 / -45 S 10.5.2 Displaying Azimuth, Elevation, and Compass HeadingsProblem Explanation Solution 11Maintenance and TroubleshootingKeyboard Commands By Number Keyboard Commands Bosch ProtocolCommands, Optical Camera Refer to .5 Azimuth, Elevation, Compass Directions, Zone/Sector Title Menu Enters the Zone Title menu. Refer toCommands, Thermal Camera 70 en MIC612 Thermal Camera Keyboard User Action Description Command Keyboard Commands Pelco ProtocolEn MIC612 Thermal Camera Index #-ENTERPre-compensation 39 sharpness 38 shutter White balance En Index MIC612 Thermal Camera Constant focus 41 manual focus 41 spot focus PTZ Custom tourZero pan ShotPage Page Bosch Security Systems, Inc

MIC612 specifications

The Bosch Appliances MIC612 is an innovative and highly efficient piece of kitchen equipment that enhances the culinary experience for home chefs and professionals alike. Renowned for its quality, Bosch has developed this compact microwave that combines advanced technology with user-friendly features.

One of the standout characteristics of the MIC612 is its sleek design, seamlessly incorporating into various kitchen styles. With its stainless-steel finish, the microwave not only offers aesthetic appeal but also ensures durability and easy maintenance. Its compact size makes it an ideal fit for smaller kitchens or areas where space is limited, while still providing ample cooking capacity.

The MIC612 is equipped with intelligent cooking technology. This includes sensor cooking, which automatically adjusts cooking time and power levels based on moisture detected in the food. This feature simplifies meal preparation by eliminating the need for constant monitoring, ensuring perfectly cooked dishes every time. Additionally, the microwave offers multiple cooking modes, including reheating, defrosting, and cooking with precision.

For those who appreciate convenience, the MIC612 includes pre-programmed settings for common foods like popcorn, pizza, and baked goods. This allows users to enjoy a wide variety of meals with minimal effort. The intuitive control panel and clear digital display enhance the ease of use, enabling quick selection of settings and cooking times.

Safety is a paramount concern for Bosch, and the MIC612 does not disappoint. It features a child safety lock, ensuring that curious little hands cannot accidentally operate the appliance. Moreover, the design incorporates a reliable cooling system to prevent overheating and ensure longevity.

Energy efficiency is another highlight of the Bosch MIC612. It is designed to consume less power compared to traditional microwaves, making it an eco-friendly choice without compromising performance. The combination of cutting-edge technology, thoughtful design, and practical features makes the Bosch Appliances MIC612 a valuable addition to any kitchen, offering versatility and reliability for all cooking needs. Whether reheating leftovers or preparing a fresh meal from scratch, this microwave stands out as a remarkable option for modern culinary tasks.