Bosch Appliances MIC612 installation manual PTZ Setup, White, Outdoor, Balance, Wiper

Page 55

MIC612 Thermal CameraOn-Screen Display (OSD) Menus (Pelco Protocol) en 55

Camera Setup Menu Choices:

 

 

 

 

 

 

Menu

Description

Sub-menu / Description

Default Setting

Exit

Exits the menu.?

 

 

White

Sets a default value in

OUTDOOR: Sets a default setting if

OUTDOOR

Balance

case the Pelco

the controller disables white balance.

 

 

controller disables the

INDOOR: Sets a default setting if the

 

 

white balance.

controller disables white balance.

 

Night Mode

Switches from color to

ON: Sets Night Mode on.

ON (Day/Night

 

monochrome.

OFF: Sets Night Mode off.

models only)

 

 

AUTO: Sets Night Mode to Auto set.

 

Wiper

 

ON/OFF: Activates/deactivates the

Continuous

 

 

selected wiper mode, respectively.

 

 

 

CONTINUOUS: Wiper wipes

 

 

 

continously until deactivated

 

 

 

manually or by the five-minute time-

 

 

 

out built in to the system.

 

 

 

INTERMITTENT: Wipes twice, then

 

 

 

turns off after 15 seconds.

 

 

 

ONE SHOT: Wipes five times, then

 

 

 

turns off.

 

 

 

WASH WIPE: Wiper washes and

 

 

 

wipes.

 

7.3

PTZ Setup

 

 

 

 

The Pelco PTZ Setup Menu provides access to the PTZ settings such as tours, scan speed,

 

 

presets, limit stops, recording, and AutoPivot.

 

 

 

 

 

 

 

 

 

PTZ Setup

 

 

 

 

 

Exit...

 

 

 

 

*

Edit Tour 1...

 

 

 

 

*

Edit Tour 2...

 

 

 

 

*

Tour 1 Period:

5 sec

 

 

 

*

Tour 2 Period:

5 sec

 

 

 

*

Scan Speed

30 deg/sec

 

 

 

 

Edit Presets...

 

 

 

 

*

Limit Stops:

OFF

 

 

 

*

Recording:

“A”

 

 

 

*

Autopivot:

ON

 

 

 

 

* = Factory Setting

 

 

 

 

 

Focus / Iris: Select

 

 

Bosch Security Systems, Inc.

Installation Manual

F.01U.249.416 2.0 2012.09

Image 55
Contents MIC612 Thermal Camera Page Table of Contents On-Screen Display OSD Menus Pelco Protocol Common User CommandsAdvanced Features On-Screen Display OSD Menus Bosch ProtocolIndex Maintenance and Troubleshooting Keyboard Commands By NumberConventions in this Manual SafetyImportant Safety Instructions About this ManualMIC612 Thermal Camera Safety en Important Notices EC DirectivesCoax grounding FCC ET Ices Information commercial applications FCC and Ices ComplianceInformations FCC ET Ices applications commerciales Bosch Notices Customer Support and ServiceUSA Additional Tools Required Parts List2Unpacking Additional Products RequiredMIC camera mounting positions Upright, Inverted Installation OverviewNumber Description Typical Mounting ArrangementsMounting Positions 3About the MIC Shielded Composite Cable About Alarm Inputs and OutputsAn 8-input alarm card installed in the MIC PSU Alarm Card Number Installed? Alarm Inputs Alarm OutputsTypical Installation Configurations InstallationMIC-BP4 sold separately Example 2 Configuration with RS-485 protocol connection Overview of Installation StepsFollow these steps in sequence to install the MIC612 camera Mounting the Camera Installing the MIC Power Supply Unit PSU Fuse Ratings Earth Link on PCB3Layout of MIC Power Supply Units PSUs for MIC612 Electrical Shock Hazard 4Installation InstructionsNumber Description PCB Marking Description AUX1 Number Description Cable Gland SizeAUX2 MIC612 Thermal Camera Installation en LED Description Power supply. Follow these stepsDisconnect the power supply from the power source Commissioning the Camera with Heater Option FittedScrewdriver Fitting the Optional Sunshield MIC612Bottom half of the sunshield see step Head is facing upEstablishing Control of the Camera via RS-485 Protocol Establishing Control of the Camera via Biphase ProtocolGetting Started Establishing Control of the CameraLCD Powering OnControlling the Camera Basic Keyboard Operation4Keyboard Commands, Pelco Protocol Keyboard Commands, Bosch ProtocolNavigating the On-Screen Display OSD Menus Special Preset Commands, Pelco Protocol 4Setting the Addresses of the Two Cameras of the MIC612Preset FastAddress, Bosch Protocol Setting the Address of the Optical Camera via FastAddressTo set FastAddress with a Pelco Keyboard 3FastAddress, Pelco ProtocolsTo set an address for a camera without an address To change or clear an address for a camera with an addressSpecial Passwords Setting PasswordsConfiguring the Camera for Inverted Operation Active Commands in FastAddress6On-Screen Display OSD Menus Bosch Protocol Setup MenuATW Camera Setup MenuWDR Thermal Camera Setup Menu Manual Lens Setup MenuPTZ Setup Menu Display Setup Menu Compass Display AdjustCamera OSD AzimuthBaud Rate Communication Setup MenuCommunication Setup AutoBaudNone Alarm SetupOSD Outputs Setup SubmenuOutputs Setup Submenu Choices OutputsRule # Choices Enabled Rule Setup SubmenuRule Setup Rule Setup Submenu ChoicesInput Language MenuOutput Bist Diagnostics MenuInternal Humidity Security AccessCtfid Access Power Up EventsTotal Time On Alarm Status SubmenuAlarm Input Alarm OutputOn-Screen Display OSD Menus Pelco Protocol Continuous Camera SetupPelco menu Bosch menu Setup Menu Bosch MenuBalance PTZ SetupWhite OutdoorOFF Other MenusFlat-Field Correction FFC Switching VideoDisplaying Thermal Camera Temperature Operation of the Thermal CameraSet the Alarm Rule Triggering Alarms On Detection of Objects Outside of SetThermal Temperature Threshold Set the Temperature ThresholdSpecifying a Shot or a Sector Title Common User CommandsSetting AutoPan Mode Setting Preset ShotsProgramming the Inactivity Operation Configuring Preposition ToursRecording Tours Using the Wiper/Washer10.1.2 Alarm Rule Examples Advanced Features10.1 Alarm Rules 10.1.1 Controlling Alarm Rules10.2 Privacy Masking Example 2 Advanced Alarm Rule10.5 Azimuth, Elevation, and Compass Directions 10.5.1 Setting the Azimuth Zero Point10.3 Image Stabilization 10.4 Pre-position Tour180 / -45 S 10.5.2 Displaying Azimuth, Elevation, and Compass HeadingsProblem Explanation Solution 11Maintenance and TroubleshootingKeyboard Commands Bosch Protocol Keyboard Commands By NumberCommands, Optical Camera Refer to .5 Azimuth, Elevation, Compass Directions, Zone/Sector Title Menu Enters the Zone Title menu. Refer toCommands, Thermal Camera 70 en MIC612 Thermal Camera Keyboard User Action Description Command Keyboard Commands Pelco ProtocolEn MIC612 Thermal Camera #-ENTER IndexPre-compensation 39 sharpness 38 shutter White balance En Index MIC612 Thermal Camera Constant focus 41 manual focus 41 spot focus PTZ Custom tourZero pan ShotPage Page Bosch Security Systems, Inc

MIC612 specifications

The Bosch Appliances MIC612 is an innovative and highly efficient piece of kitchen equipment that enhances the culinary experience for home chefs and professionals alike. Renowned for its quality, Bosch has developed this compact microwave that combines advanced technology with user-friendly features.

One of the standout characteristics of the MIC612 is its sleek design, seamlessly incorporating into various kitchen styles. With its stainless-steel finish, the microwave not only offers aesthetic appeal but also ensures durability and easy maintenance. Its compact size makes it an ideal fit for smaller kitchens or areas where space is limited, while still providing ample cooking capacity.

The MIC612 is equipped with intelligent cooking technology. This includes sensor cooking, which automatically adjusts cooking time and power levels based on moisture detected in the food. This feature simplifies meal preparation by eliminating the need for constant monitoring, ensuring perfectly cooked dishes every time. Additionally, the microwave offers multiple cooking modes, including reheating, defrosting, and cooking with precision.

For those who appreciate convenience, the MIC612 includes pre-programmed settings for common foods like popcorn, pizza, and baked goods. This allows users to enjoy a wide variety of meals with minimal effort. The intuitive control panel and clear digital display enhance the ease of use, enabling quick selection of settings and cooking times.

Safety is a paramount concern for Bosch, and the MIC612 does not disappoint. It features a child safety lock, ensuring that curious little hands cannot accidentally operate the appliance. Moreover, the design incorporates a reliable cooling system to prevent overheating and ensure longevity.

Energy efficiency is another highlight of the Bosch MIC612. It is designed to consume less power compared to traditional microwaves, making it an eco-friendly choice without compromising performance. The combination of cutting-edge technology, thoughtful design, and practical features makes the Bosch Appliances MIC612 a valuable addition to any kitchen, offering versatility and reliability for all cooking needs. Whether reheating leftovers or preparing a fresh meal from scratch, this microwave stands out as a remarkable option for modern culinary tasks.