Bosch Appliances MIC612 installation manual Recording Tours, Using the Wiper/Washer

Page 61

MIC612 Thermal CameraCommon User Commands en 61

9.6

Recording Tours

The MIC612 can make up to two (2) recorded tours. A Recorded Tour saves all manual camera movements made during the recording, including its rate of pan, tilt and zoom speeds and other lens setting changes.

To Record Tour A:

1.Press ON-100-ENTERto start recording a tour.

2.Press OFF-100-ENTERto stop recording.

To playback Recorded Tour A:

1.Press ON-50-ENTERto begin continuous playback.

2.Press OFF-50-ENTERor move the joystick to stop playback.

To Record Tour B:

1.Press ON-101-ENTERto start recording the tour.

2.Press OFF-101-ENTERto stop the tour.

To playback Recorded Tour B:

1.Press ON-52-ENTERto begin continuous playback.

2.Press OFF-52-ENTERor move the joystick to stop playback.

9.7

Using the Wiper/Washer

The "predefined position" for the wash/wipe function is preset 62. The installer must define preset 62 (preferably where the washer nozzle is located and can direct washer fluid towards the camera window) before using the wiper/washer function.

To activate the washer/wiper function:

1.Press ON-105-ENTER, and then confirm this sequence:

2.The wiper moves to a predefined position.

3.The washer turns on for five seconds. Simultaneously, the wiper turns on and wipes five times.

4.The washer turns off. The wiper continues wiping for five more wipes as the camera returns to its initial PTZ position (and to inactive mode if applicable).

5.The wiper turns off.

To activate continuous wipe:

Press ON-102-ENTER. The wiper wipes continuously for up to 5 minutes, or until another OFF-102-ENTER command is sent (if the command is sent before the 5 minutes elapse).

The wiper then turns off automatically.

To activate intermittent wipe:

Press ON-103-ENTER. The wiper wipes twice, then returns to parked position, and turns off 15 seconds later. This sequence will continue for up to 5 minutes or until an OFF-103- ENTER command is sent.

To activate the wiper to wipe five (5) times:

Press ON-104-ENTER. The wiper wipes five (5) times, or until an OFF-104-ENTER command is sent (if the command is sent before the wiper wipes five (5) times), then returns to parked position and turns off.

NOTICE!

If the power fails while the wiper is activated, the wiper will return to ’parked’ position, after power is restored, before turning off. The wiper will not stop in front of the camera window.

Bosch Security Systems, Inc.

Installation Manual

F.01U.249.416 2.0 2012.09

Image 61
Contents MIC612 Thermal Camera Page Table of Contents Advanced Features Common User CommandsOn-Screen Display OSD Menus Bosch Protocol On-Screen Display OSD Menus Pelco ProtocolIndex Maintenance and Troubleshooting Keyboard Commands By NumberImportant Safety Instructions SafetyAbout this Manual Conventions in this ManualMIC612 Thermal Camera Safety en Important Notices EC DirectivesCoax grounding FCC ET Ices Information commercial applications FCC and Ices ComplianceInformations FCC ET Ices applications commerciales Bosch Notices Customer Support and ServiceUSA 2Unpacking Parts ListAdditional Products Required Additional Tools RequiredMIC camera mounting positions Upright, Inverted Installation OverviewNumber Description Typical Mounting ArrangementsMounting Positions An 8-input alarm card installed in the MIC PSU About Alarm Inputs and OutputsAlarm Card Number Installed? Alarm Inputs Alarm Outputs 3About the MIC Shielded Composite CableTypical Installation Configurations InstallationMIC-BP4 sold separately Example 2 Configuration with RS-485 protocol connection Overview of Installation StepsFollow these steps in sequence to install the MIC612 camera Mounting the Camera Installing the MIC Power Supply Unit PSU Fuse Ratings Earth Link on PCB3Layout of MIC Power Supply Units PSUs for MIC612 Electrical Shock Hazard 4Installation InstructionsNumber Description PCB Marking Description AUX1 Number Description Cable Gland SizeAUX2 MIC612 Thermal Camera Installation en Disconnect the power supply from the power source Power supply. Follow these stepsCommissioning the Camera with Heater Option Fitted LED DescriptionBottom half of the sunshield see step Fitting the Optional Sunshield MIC612Head is facing up ScrewdriverGetting Started Establishing Control of the Camera via Biphase ProtocolEstablishing Control of the Camera Establishing Control of the Camera via RS-485 ProtocolControlling the Camera Powering OnBasic Keyboard Operation LCD4Keyboard Commands, Pelco Protocol Keyboard Commands, Bosch ProtocolNavigating the On-Screen Display OSD Menus Special Preset Commands, Pelco Protocol 4Setting the Addresses of the Two Cameras of the MIC612Preset FastAddress, Bosch Protocol Setting the Address of the Optical Camera via FastAddressTo set an address for a camera without an address 3FastAddress, Pelco ProtocolsTo change or clear an address for a camera with an address To set FastAddress with a Pelco KeyboardConfiguring the Camera for Inverted Operation Setting PasswordsActive Commands in FastAddress Special Passwords6On-Screen Display OSD Menus Bosch Protocol Setup MenuATW Camera Setup MenuWDR Thermal Camera Setup Menu Manual Lens Setup MenuPTZ Setup Menu Display Setup Menu Camera OSD Display AdjustAzimuth CompassCommunication Setup Communication Setup MenuAutoBaud Baud RateNone Alarm SetupOutputs Setup Submenu Choices Outputs Setup SubmenuOutputs OSDRule Setup Rule Setup SubmenuRule Setup Submenu Choices Rule # Choices EnabledInput Language MenuOutput Bist Diagnostics MenuCtfid Access Security AccessPower Up Events Internal HumidityAlarm Input Alarm Status SubmenuAlarm Output Total Time OnOn-Screen Display OSD Menus Pelco Protocol Pelco menu Bosch menu Setup Menu Camera SetupBosch Menu ContinuousWhite PTZ SetupOutdoor BalanceOFF Other MenusDisplaying Thermal Camera Temperature Switching VideoOperation of the Thermal Camera Flat-Field Correction FFCThermal Temperature Threshold Triggering Alarms On Detection of Objects Outside of SetSet the Temperature Threshold Set the Alarm RuleSetting AutoPan Mode Common User CommandsSetting Preset Shots Specifying a Shot or a Sector TitleProgramming the Inactivity Operation Configuring Preposition ToursRecording Tours Using the Wiper/Washer10.1 Alarm Rules Advanced Features10.1.1 Controlling Alarm Rules 10.1.2 Alarm Rule Examples10.2 Privacy Masking Example 2 Advanced Alarm Rule10.3 Image Stabilization 10.5.1 Setting the Azimuth Zero Point10.4 Pre-position Tour 10.5 Azimuth, Elevation, and Compass Directions180 / -45 S 10.5.2 Displaying Azimuth, Elevation, and Compass HeadingsProblem Explanation Solution 11Maintenance and TroubleshootingKeyboard Commands Bosch Protocol Keyboard Commands By NumberCommands, Optical Camera Refer to .5 Azimuth, Elevation, Compass Directions, Zone/Sector Title Menu Enters the Zone Title menu. Refer toCommands, Thermal Camera 70 en MIC612 Thermal Camera Keyboard User Action Description Command Keyboard Commands Pelco ProtocolEn MIC612 Thermal Camera #-ENTER IndexPre-compensation 39 sharpness 38 shutter White balance En Index MIC612 Thermal Camera Constant focus 41 manual focus 41 spot focus PTZ Custom tourZero pan ShotPage Page Bosch Security Systems, Inc

MIC612 specifications

The Bosch Appliances MIC612 is an innovative and highly efficient piece of kitchen equipment that enhances the culinary experience for home chefs and professionals alike. Renowned for its quality, Bosch has developed this compact microwave that combines advanced technology with user-friendly features.

One of the standout characteristics of the MIC612 is its sleek design, seamlessly incorporating into various kitchen styles. With its stainless-steel finish, the microwave not only offers aesthetic appeal but also ensures durability and easy maintenance. Its compact size makes it an ideal fit for smaller kitchens or areas where space is limited, while still providing ample cooking capacity.

The MIC612 is equipped with intelligent cooking technology. This includes sensor cooking, which automatically adjusts cooking time and power levels based on moisture detected in the food. This feature simplifies meal preparation by eliminating the need for constant monitoring, ensuring perfectly cooked dishes every time. Additionally, the microwave offers multiple cooking modes, including reheating, defrosting, and cooking with precision.

For those who appreciate convenience, the MIC612 includes pre-programmed settings for common foods like popcorn, pizza, and baked goods. This allows users to enjoy a wide variety of meals with minimal effort. The intuitive control panel and clear digital display enhance the ease of use, enabling quick selection of settings and cooking times.

Safety is a paramount concern for Bosch, and the MIC612 does not disappoint. It features a child safety lock, ensuring that curious little hands cannot accidentally operate the appliance. Moreover, the design incorporates a reliable cooling system to prevent overheating and ensure longevity.

Energy efficiency is another highlight of the Bosch MIC612. It is designed to consume less power compared to traditional microwaves, making it an eco-friendly choice without compromising performance. The combination of cutting-edge technology, thoughtful design, and practical features makes the Bosch Appliances MIC612 a valuable addition to any kitchen, offering versatility and reliability for all cooking needs. Whether reheating leftovers or preparing a fresh meal from scratch, this microwave stands out as a remarkable option for modern culinary tasks.