Bosch Power Tools 2000 11.2Digit 2, Alarm Responses, Series Program Entry Guide, Point Codes

Page 43
11.2Digit 2, Alarm Responses

2000 Series Program Entry Guide 11.0

Point Codes

 

 

EN 43

11.2Digit 2, Alarm Responses

Table 6: Digit 2 Selections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

 

No Alarm Response: Set Digit 2 to 0 (zero) only if you want no alarm response for

X

 

 

 

 

 

 

 

 

 

 

 

this point.

 

 

 

 

 

 

 

 

 

 

 

 

Note:

 

 

 

 

 

 

 

 

 

 

 

 

Set Digit 2 to 0 if you are using this point number for an RF Keypad or arming device.

 

 

 

 

 

 

 

 

 

 

 

 

Reports: Points send Alarm, Cancel, Trouble, Bypass, Swinger Bypass, and Restoral

 

X

X

X

X

 

X

X

X

 

X

 

Reports as programmed. Bypass Reports are only sent with Closing Reports.

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Report Delay: If a user enters their passcode to silence an alarm before the

 

 

X

X

 

 

 

X

X

 

 

 

programmed Alarm Report Delay time expires, the alarm is canceled. No Alarm,

 

 

 

 

 

 

 

 

 

 

 

 

Cancel, or Restoral Report is sent. Program Delay Alrm Rpt in Section 3.0 Reports

 

 

 

 

 

 

 

 

 

 

 

 

to determine the duration of the delay.

 

 

 

 

 

 

 

 

 

 

 

 

Voice Active Function: When the Delay Alrm Rpt prompt is set to 255, Alarm

 

 

 

 

 

 

 

 

 

 

 

 

Report Delay points (Digit 2 = 2, 3, 7, or 8) begin the 2-way Voice Verification

 

 

 

 

 

 

 

 

 

 

 

 

process. Refer to Delay Alrm Rpt in Section 3.0 Reports.

 

 

 

 

 

 

 

 

 

 

 

 

Duress Reports and A, B, C Key Reports are not affected by the Alarm Report

 

 

 

 

 

 

 

 

 

 

 

 

Delay. These reports are sent immediately in all cases.

 

 

 

 

 

 

 

 

 

 

 

 

Swinger Bypass: The Swinger Count prompt in the System Configuration Group

 

 

 

X

X

 

 

 

X

 

X

 

sets the swinger count for this Swinger Bypass point option. When the number of

 

 

 

 

 

 

 

 

 

 

 

 

alarms or troubles in an armed or disarmed period reaches the swinger count, the

 

 

 

 

 

 

 

 

 

 

 

 

system automatically bypasses points programmed for Swinger Bypass. Turning the

 

 

 

 

 

 

 

 

 

 

 

 

system off clears the bypass. If a 24-hour point swinger bypasses while the system is

 

 

 

 

 

 

 

 

 

 

 

 

off, turning the system on (starting exit delay) and then turning the system off

 

 

 

 

 

 

 

 

 

 

 

 

(pressing [CLEAR]) clears the bypass. Swinger bypass is a point trouble and

 

 

 

 

 

 

 

 

 

 

 

 

activates the Point Trouble Relay function.

 

 

 

 

 

 

 

 

 

 

 

 

When a point is swinger bypassed, the Point Trouble Relay is activated.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Output: Points programmed for alarm output provide output at Terminals 4

 

 

 

 

 

X

X

X

X

 

X

 

and 5 as part of the alarm response. Fire points provide a pulsed output. Non-Fire

 

 

 

 

 

 

 

 

 

 

 

 

points provide a steady output. Output lasts for the duration programmed in Bell

 

 

 

 

 

 

 

 

 

 

 

 

Time. Fire output always takes precedence over non-fire output.

 

 

 

 

 

 

 

 

 

 

 

 

Bosch Security Systems 7/05 35114F

Image 43
Contents 2000 Series Control PanelsBosch Security Systems 7/05 35114F Using this Guide for Keypad ProgrammingAbout This Manual E Version Control PanelsBosch Security Systems 7/05 35114F Contents2000 Series Program Entry Guide Contents An Example, Entering Custom TextTables Figures2000 Series Program Entry Guide Contents 2000 Series Program Entry Guide 1.0 System ConfigurationSystem Configuration 3 Keyswitch2000 Series Program Entry Guide 6 Custom Service TextSystem Configuration Default BlankPhone 2.0 Phone2.1Phone Routing Set to No Phone Routing Set to Yes8 Restoral Route 5 Fire Route6 Non-FireRoute 7 Pt Trbl Route14 Duress Route 11 Cancel Route12 Sys Trbl Route 13 Sys Trbl RoutePhone 15 Test RouteDefault: Local 2000 Series Program Entry Guide3 Restricted O/C 3.0 ReportsReports 1 O/C Rpts - All On2000 Series Program Entry Guide 5 Cancel Rpt6 Restoral Rpts 7 AC Fail Buzz/RptReports 8 Point User FlagDefault 2000 Series Program Entry GuideBosch Security Systems | 7/05 | 35114F 2000 Series Program Entry GuideReports EN1 Rcvr Format 4.0Receiver4.1Modem Reports ReceiverTable 2 continued 2000 Series Program Entry GuideReceiver ENTable 2 continued 2000 Series Program Entry GuideReceiver EN2 Fire Group 4.2Pulse Report Groups1 - Account number 2 - Report group 3 - Point, user5 Restoral Group 8 Cancel Group3 Non-FireGroup 4 Pt Trbl Group2000 Series Program Entry Guide 10 Sys Res Group11 Duress Group 12 Test Group2 RAM Phone 5.0 Remote ProgrammingRemote Programming 1 RAM PasscodeRemote Programming 2000 Series Program Entry GuideEN 2 Exit Dly Time 6.0 Open/CloseOpen/Close 1 Entry Dly Time2000 Series Program Entry Guide 6.1Step Outside5 No Delay 6 Excursion2000 Series Program Entry Guide 6.2ExitOpen/Close Bosch Security Systems 7/05 35114F 2000 Series Program Entry GuideOpen/Close EN1 A-KeyReport 2 A-KeyAlarm Output7.0ABC Keys ABC Keys10 C-KeyOutput 5B-KeyAlarm Report 6 B-KeyOutput 7 B-KeyAck Tone9 C-KeyAlarm Report 8 B-KeyText1 Bell Time 4 Alarm on 2 Fail8.0 Bell BellBosch Security Systems 7/05 35114F 2000 Series Program Entry GuideBell EN2 Hours to Next 9.0 Test TimerTest Timer 1 Test Interval2000 Series Program Entry Guide Test TimerThe report defers one interval from the time of the last report. For example, if theTest Intrvl prompt is set to 1 Day, and the system transmits an Opening Report at 9 00 PM, the interval begins at 9 00 PM. If the system transmitted no other reports before 9 00 PM the following day, at 9 00 PM the system transmits the Test Report 6 Address 7 Address 8 Address 10.0 Address ConfigurationAddress Configuration 1 Address 2 Address 3 Address 4 Address 5 AddressBosch Security Systems 7/05 35114F Address Configuration2000 Series Program Entry Guide EN2 Point 11.0 Point CodesPoint Codes 1 Point7 to 24 Points 7 to 4 Point5 Point 6 PointPoint Codes 11.1Digit 1, Point TypeRefer to Section 11.3 Digit 3, Point Options 2000 Series Program Entry GuideEN 11.3 Digit 3, Point Options2000 Series Program Entry Guide Point CodesPoint Codes 2000 Series Program Entry GuideEN Point Codes 2000 Series Program Entry GuideEN Point Codes 2000 Series | Program Entry Guide |EN EN the Extended Delay feature2000 Series Program Entry Guide Point Codes2000 Series Program Entry Guide 11.2Digit 2, Alarm ResponsesPoint Codes EN 11.3Digit 3, Point Options2000 Series Program Entry Guide Point CodesEN 11.4Digit 4, Device Address2000 Series Program Entry Guide Point Codes2000 Series Program Entry Guide 11.5Digit 5, Sensor LoopPoint Codes Table 9 Digit Selection Summary 2000 Series Program Entry GuidePoint Codes EN2000 Series Program Entry Guide 11.6 Recommended Point CodesPoint Codes Point Codes 2000 Series Program Entry GuideTable 16 Panic Device swinger bypass Bosch Security Systems 7/05 35114F 2000 Series Program Entry GuidePoint Codes EN2000 Series Program Entry Guide 12.0 Point TextPoint Text 1 to 24 Point TextBosch Security Systems 7/05 35114F 2000 Series Program Entry GuidePoint Text ENRelays 13.0 Relays13.1Relay Function Logic 13.2Relay FunctionsEN the Parameter prompt2000 Series Program Entry Guide RelaysRelays 2000 Series Program Entry GuideEN 2000 Series Program Entry Guide 13.3Relay Parameters, for Keypad Programming OnlyRelays 1 User Tst, Bell 2 User Tst, Battery14.0 User Test User TestBosch Security Systems 7/05 35114F 2000 Series Program Entry GuideUser Test EN2 Passcode Length 15.0 PasscodesPasscodes 1 Instir Codepasscode for up to eight users 5 Change PasscodePasscode-# the Passcode Type and to enter a unique2000 Series Program Entry Guide 16.0 RF ParametersRF Parameters 1 Supervision IntervalBosch Security Systems 7/05 35114F 2000 Series Program Entry GuideRF Parameters ENProgram Lock 1 Return to Default3 Disable System 17.0 Program LockBosch Security Systems 7/05 35114F 2000 Series Program Entry GuideProgram Lock ENKeypad Programming 18.0Keypad Programming18.1Getting Started 18.2View Mode18.4 Scroll Lists 18.3Modify Mode18.4Scroll Lists 18.5Yes and No Entries2000 Series Program Entry Guide 18.6An Example, Entering Custom TextKeypad Programming 2000 Series Program Entry Guide 18.7Keypad Programming TipsKeypad Programming 2000 Series Program Entry Guide Index Index2000 Series Program Entry Guide Index 2000 Series Program Entry Guide Index 2005 Bosch Security Systems 35114F Fairport, NY Customer ServiceBosch Security Systems 130 Perinton Parkway Technical Support