Modem II Report

POINT BYPASS POINT 001 (-024)

RAM ACCESS OK

RAM ACCESS FAIL

RESTORAL REPORT POINT 001 (-024)

Description

Point 1 to 24 bypassed. Points can be bypassed from the keypad or from a remote programmer. Bypass Reports are only sent when Opening and Closing Reports are enabled in Section 6.0 Open/Close.

Normal remote programmer session termination.

Remote programmer made connection with control panel, but passcode was incorrect, or call was not terminated with a Good-bye or Reset-Bye.

Restoral Report from Points 1 to 24.

RE-BOOT

RF BATTERY LOW POINT 001 (-024)

Control panel reset with the standby pin (Refer to Installation Manual) or a remote programmer.

Low battery in RF sensor, keypad, or arming device.

RF BATT RESTORE

Restored battery in RF sensor, keypad, or arming device.

POINT 001 (-024)

 

 

 

RF Rcvr Tamper SDI 7 (8)

RF Rcvr Tamper

Restoral

SDI 7 (8)

RF Rcvr Trouble Device 7 (8)

Enclosure tamper from premises RF receiver (D208RF, D216RF).

SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.

Enclosure tamper restoral from premises RF receiver (D208RF, D216RF).

SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.

Trouble from premises RF receiver (D208RF, D216RF)

SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.

RF Rcvr Trbl

Restoral from premises RF receiver (D208RF, D216RF)

Restoral

 

SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.

Device 7

(8)

 

RF TAMPER TROUBLE

RF TAMPER RESTORAL

SERVICE START

SERVICE STOP

SWINGER BYPASS POINT 001 (-024)

TEST REPORT

TROUBLE REPORT POINT 001 (-024)

Tamper RF point, Controlled point, system off.

Tamper restoral, RF point.

Installer mode entered (Stand-by locked down, installer passcode entered).

Installer mode exited.

Points 1 to 24 bypassed automatically by the system after four alarms or troubles in one armed or disarmed period. You can program the Swinger Bypass feature to activate after less than four alarms or troubles. Refer to Swinger Count prompt in Section 1.0 System Configuration.

Use the point code to program this feature by point. Refer to Section 11.0 Point Codes.

Automatic Test Timer Report.

Trouble on Points 1 to 24, Fire and Non-fire combined.

USR CODE

TAMPER

This report transmitted after six attempts to enter an invalid passcode.

WATCHDOG

RESET

System automatically reset. Call Bosch Security Systems if reports persist.

 

 

 

 

 

 

0101

0101

0101

If you choose Modem Format, go to Section 5.0 Remote Programming. The prompts in the remainder of the Receiver Group have no meaning for the Modem Format.

Bosch Security Systems 7/05 35114F

Image 17
Contents 2000 Series Control PanelsAbout This Manual Using this Guide for Keypad ProgrammingE Version Control Panels Bosch Security Systems 7/05 35114F2000 Series Program Entry Guide Contents ContentsAn Example, Entering Custom Text Bosch Security Systems 7/05 35114F2000 Series Program Entry Guide Contents FiguresTables System Configuration 1.0 System Configuration3 Keyswitch 2000 Series Program Entry GuideSystem Configuration 6 Custom Service TextDefault Blank 2000 Series Program Entry Guide2.1Phone Routing Set to No 2.0 PhonePhone Routing Set to Yes Phone6 Non-FireRoute 5 Fire Route7 Pt Trbl Route 8 Restoral Route12 Sys Trbl Route 11 Cancel Route13 Sys Trbl Route 14 Duress RouteDefault: Local 15 Test Route2000 Series Program Entry Guide PhoneReports 3.0 Reports1 O/C Rpts - All On 3 Restricted O/C6 Restoral Rpts 5 Cancel Rpt7 AC Fail Buzz/Rpt 2000 Series Program Entry GuideDefault 8 Point User Flag2000 Series Program Entry Guide ReportsReports 2000 Series Program Entry GuideEN Bosch Security Systems | 7/05 | 35114F4.1Modem Reports 4.0ReceiverReceiver 1 Rcvr FormatReceiver 2000 Series Program Entry GuideEN Table 2 continuedReceiver 2000 Series Program Entry GuideEN Table 2 continued1 - Account number 2 - Report group 4.2Pulse Report Groups3 - Point, user 2 Fire Group3 Non-FireGroup 8 Cancel Group4 Pt Trbl Group 5 Restoral Group11 Duress Group 10 Sys Res Group12 Test Group 2000 Series Program Entry GuideRemote Programming 5.0 Remote Programming1 RAM Passcode 2 RAM PhoneEN 2000 Series Program Entry GuideRemote Programming Open/Close 6.0 Open/Close1 Entry Dly Time 2 Exit Dly Time5 No Delay 6.1Step Outside6 Excursion 2000 Series Program Entry GuideOpen/Close 6.2Exit2000 Series Program Entry Guide Open/Close 2000 Series Program Entry GuideEN Bosch Security Systems 7/05 35114F7.0ABC Keys 2 A-KeyAlarm OutputABC Keys 1 A-KeyReport9 C-KeyAlarm Report 5B-KeyAlarm Report 6 B-KeyOutput 7 B-KeyAck Tone8 B-KeyText 10 C-KeyOutput8.0 Bell 4 Alarm on 2 FailBell 1 Bell TimeBell 2000 Series Program Entry GuideEN Bosch Security Systems 7/05 35114FTest Timer 9.0 Test Timer1 Test Interval 2 Hours to NextThe report defers one interval from the time of the last report. For example, if theTest Intrvl prompt is set to 1 Day, and the system transmits an Opening Report at 9 00 PM, the interval begins at 9 00 PM. If the system transmitted no other reports before 9 00 PM the following day, at 9 00 PM the system transmits the Test Report Test Timer2000 Series Program Entry Guide Address Configuration 10.0 Address Configuration1 Address 2 Address 3 Address 4 Address 5 Address 6 Address 7 Address 8 Address2000 Series Program Entry Guide Address ConfigurationEN Bosch Security Systems 7/05 35114FPoint Codes 11.0 Point Codes1 Point 2 Point5 Point 4 Point6 Point 7 to 24 Points 7 toRefer to Section 11.3 Digit 3, Point Options 11.1Digit 1, Point Type2000 Series Program Entry Guide Point Codes2000 Series Program Entry Guide 11.3 Digit 3, Point OptionsPoint Codes ENEN 2000 Series Program Entry GuidePoint Codes EN 2000 Series Program Entry GuidePoint Codes EN 2000 Series | Program Entry Guide |Point Codes 2000 Series Program Entry Guide the Extended Delay featurePoint Codes ENPoint Codes 11.2Digit 2, Alarm Responses2000 Series Program Entry Guide 2000 Series Program Entry Guide 11.3Digit 3, Point OptionsPoint Codes EN2000 Series Program Entry Guide 11.4Digit 4, Device AddressPoint Codes ENPoint Codes 11.5Digit 5, Sensor Loop2000 Series Program Entry Guide Point Codes 2000 Series Program Entry GuideEN Table 9 Digit Selection SummaryPoint Codes 11.6 Recommended Point Codes2000 Series Program Entry Guide Table 16 Panic Device swinger bypass 2000 Series Program Entry GuidePoint Codes Point Codes 2000 Series Program Entry GuideEN Bosch Security Systems 7/05 35114FPoint Text 12.0 Point Text1 to 24 Point Text 2000 Series Program Entry GuidePoint Text 2000 Series Program Entry GuideEN Bosch Security Systems 7/05 35114F13.1Relay Function Logic 13.0 Relays13.2Relay Functions Relays2000 Series Program Entry Guide the Parameter promptRelays ENEN 2000 Series Program Entry GuideRelays Relays 13.3Relay Parameters, for Keypad Programming Only2000 Series Program Entry Guide 14.0 User Test 2 User Tst, BatteryUser Test 1 User Tst, BellUser Test 2000 Series Program Entry GuideEN Bosch Security Systems 7/05 35114FPasscodes 15.0 Passcodes1 Instir Code 2 Passcode LengthPasscode-# 5 Change Passcodethe Passcode Type and to enter a unique passcode for up to eight usersRF Parameters 16.0 RF Parameters1 Supervision Interval 2000 Series Program Entry GuideRF Parameters 2000 Series Program Entry GuideEN Bosch Security Systems 7/05 35114F3 Disable System 1 Return to Default17.0 Program Lock Program LockProgram Lock 2000 Series Program Entry GuideEN Bosch Security Systems 7/05 35114F18.1Getting Started 18.0Keypad Programming18.2View Mode Keypad Programming18.4Scroll Lists 18.3Modify Mode18.5Yes and No Entries 18.4 Scroll ListsKeypad Programming 18.6An Example, Entering Custom Text2000 Series Program Entry Guide Keypad Programming 18.7Keypad Programming Tips2000 Series Program Entry Guide 2000 Series Program Entry Guide Index Index2000 Series Program Entry Guide Index 2000 Series Program Entry Guide Index Bosch Security Systems 130 Perinton Parkway Fairport, NY Customer ServiceTechnical Support 2005 Bosch Security Systems 35114F