Bosch Power Tools 2000 manual Series Program Entry Guide, Receiver, continued

Page 16
Table 2: continued

2000 Series Program Entry Guide 4.0

Receiver

 

 

EN 16

Table 2: continued

Modem II Report

CLOSING REPORT

CLOSING REPORT ID 001 (-008)

COMM FAIL

PHONE (1-2)

COMM RESTORAL

PHONE (1-2)

DURESS

ID 008

EXIT ERROR 001 (-024)

FIRE ALARM POINT 001 (-099)

FIRE ALARM CROSS POINT 001 (-024)

MISSING ALARM POINT 001 (-024)

MISSING TROUBLE POINT 001 (-024)

OPENING REPORT

OPENING REPORT ID 001 (-008)

OPEN FROM ALARM

OPEN FROM ALARM ID 001 (-008)

PERM INST ARMED

PERM INST ARMED ID 001 (-008)

PERM DLAY ARMED

PERM DLAY ARMED ID 001 (-008)

Description

Closing Report when passcode is not used. Refer to the Passcode Rquired prompt in Section

15.0Passcodes. Using a Keyswitch or a remote programmer also sends this Closing Report with no user ID.

Closing Report with user ID for users 1 to 8.

Communication Failure event. Refer to Phone 1, Phone 2 in Section 2.0 Phone.

Successful communication after a Communication Failure event. Refer to Phone 1, Phone 2 in the Section 2.0 Phone.

Passcode 8 used to turn the system on, turn the system off, or to silence an alarm. Refer to the Code 8 = Duress prompt in Section 15.0 Passcodes.

When a point is faulted at the end of exit delay it generates an Exit Alarm.

Exit Alarm Report from Points 1 to 24.

Fire Alarm Report from Points 1 to 24.

Cross Point Fire Alarm Report from Points 1 to 24.

Missing Non-fire Controlled point, point is on (armed). Alarm response locally.

Missing Non-fire Controlled point, point is off (disarmed), or 24-hour Non-fire point. Trouble response locally.

Turning the system off with a keyswitch or a remote programmer sends this Opening Report with no User ID.

Opening Report with User ID for users 1 to 8.

Turning the system off after an alarm with a Keyswitch point or a remote programmer sends this Opening Report with no User ID.

Opening Report after an alarm with User ID for users 1 to 8.

Remote programmer used to turn the system Part On with No Delays, or user turned the system Part On with No Delays and no passcode required. Refer to the Passcode Rquired prompt in Section 15.0 Passcodes.

User with ID shown (1 to 8) turned the system Part On with No Delays.

Remote programmer used to turn the system Part On (with Delays), or user turned the system Part On with Delays and no passcode required. Refer to the Passcode Rquired prompt in Section 15.0 Passcodes.

User with ID shown (1 to 8) turned the system Part On (with Delays).

Bosch Security Systems 7/05 35114F

Image 16
Contents Control Panels 2000 SeriesUsing this Guide for Keypad Programming About This ManualE Version Control Panels Bosch Security Systems 7/05 35114FContents 2000 Series Program Entry Guide ContentsAn Example, Entering Custom Text Bosch Security Systems 7/05 35114FTables Figures2000 Series Program Entry Guide Contents 1.0 System Configuration System Configuration3 Keyswitch 2000 Series Program Entry Guide6 Custom Service Text System ConfigurationDefault Blank 2000 Series Program Entry Guide2.0 Phone 2.1Phone Routing Set to NoPhone Routing Set to Yes Phone5 Fire Route 6 Non-FireRoute7 Pt Trbl Route 8 Restoral Route11 Cancel Route 12 Sys Trbl Route13 Sys Trbl Route 14 Duress Route15 Test Route Default: Local2000 Series Program Entry Guide Phone3.0 Reports Reports1 O/C Rpts - All On 3 Restricted O/C5 Cancel Rpt 6 Restoral Rpts7 AC Fail Buzz/Rpt 2000 Series Program Entry Guide8 Point User Flag Default2000 Series Program Entry Guide Reports2000 Series Program Entry Guide ReportsEN Bosch Security Systems | 7/05 | 35114F4.0Receiver 4.1Modem ReportsReceiver 1 Rcvr Format2000 Series Program Entry Guide ReceiverEN Table 2 continued2000 Series Program Entry Guide ReceiverEN Table 2 continued4.2Pulse Report Groups 1 - Account number 2 - Report group3 - Point, user 2 Fire Group8 Cancel Group 3 Non-FireGroup4 Pt Trbl Group 5 Restoral Group10 Sys Res Group 11 Duress Group12 Test Group 2000 Series Program Entry Guide5.0 Remote Programming Remote Programming1 RAM Passcode 2 RAM PhoneRemote Programming 2000 Series Program Entry GuideEN 6.0 Open/Close Open/Close1 Entry Dly Time 2 Exit Dly Time6.1Step Outside 5 No Delay6 Excursion 2000 Series Program Entry Guide2000 Series Program Entry Guide 6.2ExitOpen/Close 2000 Series Program Entry Guide Open/CloseEN Bosch Security Systems 7/05 35114F2 A-KeyAlarm Output 7.0ABC KeysABC Keys 1 A-KeyReport5B-KeyAlarm Report 6 B-KeyOutput 7 B-KeyAck Tone 9 C-KeyAlarm Report8 B-KeyText 10 C-KeyOutput4 Alarm on 2 Fail 8.0 BellBell 1 Bell Time2000 Series Program Entry Guide BellEN Bosch Security Systems 7/05 35114F9.0 Test Timer Test Timer1 Test Interval 2 Hours to Next2000 Series Program Entry Guide Test TimerThe report defers one interval from the time of the last report. For example, if theTest Intrvl prompt is set to 1 Day, and the system transmits an Opening Report at 9 00 PM, the interval begins at 9 00 PM. If the system transmitted no other reports before 9 00 PM the following day, at 9 00 PM the system transmits the Test Report 10.0 Address Configuration Address Configuration1 Address 2 Address 3 Address 4 Address 5 Address 6 Address 7 Address 8 AddressAddress Configuration 2000 Series Program Entry GuideEN Bosch Security Systems 7/05 35114F11.0 Point Codes Point Codes1 Point 2 Point4 Point 5 Point6 Point 7 to 24 Points 7 to11.1Digit 1, Point Type Refer to Section 11.3 Digit 3, Point Options2000 Series Program Entry Guide Point Codes11.3 Digit 3, Point Options 2000 Series Program Entry GuidePoint Codes ENPoint Codes 2000 Series Program Entry GuideEN Point Codes 2000 Series Program Entry GuideEN Point Codes 2000 Series | Program Entry Guide |EN the Extended Delay feature 2000 Series Program Entry GuidePoint Codes EN2000 Series Program Entry Guide 11.2Digit 2, Alarm ResponsesPoint Codes 11.3Digit 3, Point Options 2000 Series Program Entry GuidePoint Codes EN11.4Digit 4, Device Address 2000 Series Program Entry GuidePoint Codes EN2000 Series Program Entry Guide 11.5Digit 5, Sensor LoopPoint Codes 2000 Series Program Entry Guide Point CodesEN Table 9 Digit Selection Summary2000 Series Program Entry Guide 11.6 Recommended Point CodesPoint Codes Point Codes 2000 Series Program Entry GuideTable 16 Panic Device swinger bypass 2000 Series Program Entry Guide Point CodesEN Bosch Security Systems 7/05 35114F12.0 Point Text Point Text1 to 24 Point Text 2000 Series Program Entry Guide2000 Series Program Entry Guide Point TextEN Bosch Security Systems 7/05 35114F13.0 Relays 13.1Relay Function Logic13.2Relay Functions Relaysthe Parameter prompt 2000 Series Program Entry GuideRelays ENRelays 2000 Series Program Entry GuideEN 2000 Series Program Entry Guide 13.3Relay Parameters, for Keypad Programming OnlyRelays 2 User Tst, Battery 14.0 User TestUser Test 1 User Tst, Bell2000 Series Program Entry Guide User TestEN Bosch Security Systems 7/05 35114F15.0 Passcodes Passcodes1 Instir Code 2 Passcode Length5 Change Passcode Passcode-#the Passcode Type and to enter a unique passcode for up to eight users16.0 RF Parameters RF Parameters1 Supervision Interval 2000 Series Program Entry Guide2000 Series Program Entry Guide RF ParametersEN Bosch Security Systems 7/05 35114F1 Return to Default 3 Disable System17.0 Program Lock Program Lock2000 Series Program Entry Guide Program LockEN Bosch Security Systems 7/05 35114F18.0Keypad Programming 18.1Getting Started18.2View Mode Keypad Programming18.3Modify Mode 18.4Scroll Lists18.5Yes and No Entries 18.4 Scroll Lists2000 Series Program Entry Guide 18.6An Example, Entering Custom TextKeypad Programming 2000 Series Program Entry Guide 18.7Keypad Programming TipsKeypad Programming Index 2000 Series Program Entry Guide Index2000 Series Program Entry Guide Index 2000 Series Program Entry Guide Index Fairport, NY Customer Service Bosch Security Systems 130 Perinton ParkwayTechnical Support 2005 Bosch Security Systems 35114F