New Buck Corporation 384 manual Replacement Parts, Sit Millivolt Valve, Key#, Part Description

Page 48

REPLACEMENT PARTS

 

SIT MILLIVOLT VALVE

 

 

Picture on Page 45

 

KEY#

PART DESCRIPTION

PART NUMBER

1.

820 MV. S.I.T. VALVE

LP-PE 820636

 

 

NAT– PE 820637

2.

GENERATOR

(PILOT ASSEMBLY)

3.

BURNER TUBE

PO DTBURN

4.

O.D.S PILOT (L.P.) O.P. ASSEMBLY

PE 8404C

 

O.D.S PILOT (NAT.) O.P. ASSEMBLY

PE 8204C

5.

THERMO-COUPLE

(PILOT ASSEMBLY)

6.

2"-3/8" BLACKIRON NIPPLE

PO 382BINIP

7.

BURNER SUPPLY LINE ELBOW

PH4966

8.

21" PILOT TUBE 3/16"

MF 31621ALMTUB

9.

ORIFICE

PO ORIFICE

10.

ORIFICE HOLDER

PO 54ORFHLD

11.

3/8" NUT & SLEEVE

PH 616 & PH 606

12.

PIEZO STRIKER

PE 124461

13.CARLING SWITCH

 

(AUTO/OFF/MANUAL)

PE RC211RB

14.

12" SWITCH WIRES

PE 12JUMPER

15.

12" GENERATOR WIRE

(PILOT ASSEMBLY)

16.

14 3/4" x 3/8" BURNER SUPPLY TUBE

PO 381434ALMTUB

17.

3/8" FIP TO 1/2" MPT PIPE BUSHING

PH 11086

18.

1/2" BALL VALVE WITH PRESSURE TAP

PO 110-553

19.

1/2" FLARE TO 1/2" STRAIGHT

(FLEX LINE ASSEMBLY)

20.

1/2" FLEX LINE

PO 20-213-12

21.

1/2" FLARE TO 3/8" FLARE

PH 4286

 

OTHER PARTS (NOT SHOWN)

22.

Blower Motor

PE SBR084

23.

Power Cord

PE 400240

24.

Strain Release

PE 400320

25.

Thermostat

PE 400130

26.

Male Terminals

PE 5X428

27.

Jumper Wire 12"

PE 12JUMPER

28.

Gas Log Set

PO CR34LOG

29.

Fan Speed Control Label

PE KB9724

30.

Rheostat

PE BC204

31.

Rheostat Knob

PE BC204A

32.

Heyco 1-1/4" Grommet

PO HEYCO 2883

Page 44

Image 48
Contents MODEL VENT-FREEManufacturer NEW BUCK CORPORATION P.O. Box 8000 Highway 226 South Spruce Pine, NCPage TABLE OF CONTENTS Page SECTION I SAFETY INFORMATION WARNINGS 6. What To Do IF You Smell Gas Shut off gas supply 32. This appliance is intended for supplemental heating SECTION FIREPLACE PREPARATIONINSTALLATION AND CLEARANCES GAS CONNECTIONFLAME Page “MILLIVOLT ONLY” GAS PRESSURE CHECK FOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTION MODULATING OR MANUAL VALVE SITLIGHTING INSTRUCTION 12. Close access panel door 13. Turn on all electrical power to the applianceto “ON” position. Continue to turn the to your desired setting MANUAL LIGHTING PROCEDURE THERMOSTAT CONTROL OPERATIONFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS SIT-MILLIVOLT VALVEOPERATING INSTRUCTIONS Page Page MANUAL LIGHTING PROCEDURE WHEN USED AS A HEATING APPLIANCE HEAT OUTPUT FLAME CHECKCR 3329 LOG SET WIRING DIAGRAM NOTE #PE SBR084 Blower Motor Rating 120 volts/60HZ/1.1 Amps SECTION INSTALLATION MODEL 384 FP IN SOLID FUEL BURNING FIREPLACES Trim KitCEILING Also provide adequate clearances around air openings SECTION INSTALLATION OF MODEL 384 WS WITH OPTIONAL WOODEN SURROUND KIT#PAKDM384STEP 7 Remove cloth or blanket from underneath stove SECTION ZERO CLEARANCE INSTALLATION OF MODEL 384 ZC CHOOSING THE LOCATION FOR YOUR FIREPLACEGAS LINE DRAFTSZERO CLEARANCE STANDOFFS ASSEMBLY “Follow the instructions given in the diagrams below exactly”Top Standoff 2 per unit 12.50” Front Of Top Trim PanelINSTALLING THE FIREBOX FIREPLACE CLEARANCESInstall the Firebox Framing the FireboxFINISHING YOUR FIREPLACE CLEARANCESSECTION MODEL 384 FS FREESTANDING INSTALLATION FREESTANDING PEDESTAL OR LEGS INSTALLATION SECTION MODEL ALCOVE INSTALLATION CAUTION READ ENTIRE MANUAL BEFORE INSTALLING HEATERSECTION PRODUCING ADEQUATE VENTILATION DETERMINING FRESH-AIR FLOW FOR HEATER LOCATIONThis section is for residential or manufactured mobile installation 1. Determine the volume of the space length x width x height SECTION VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDINGVENTILATION AIR FROM OUTDOORS Ventilation Air From OutdoorsSECTION AFTER MARKET MOBILE HOME INSTALLATION IMPORTANT SAFEGUARDS CLEANINGOBSERVED Air in gas lines when OBSERVED OBSERVED REPAIR PARTS SERVICINGREPLACEMENT PARTS SIT MODULATING OR MANUAL VALVEKEY# PART DESCRIPTION1719 PILOTREPLACEMENT PARTS SIT MILLIVOLT VALVESIT MILLIVOLT REPLACEMENT PARTS FOR EMBER STOVE BASE ESB SIT MILLIVOLT 10 one is not available, you may contactPage LIMITED WARRANTY VENT-FREE GAS LOG HEATER NEW BUCK CORPORATIONPage