New Buck Corporation 384 manual Observed

Page 43
Manual background

 

 

OBSERVED

POSSIBLE

 

 

 

 

 

 

PROBLEM

CAUSE

SOLUTION

 

 

Burner does not light after ODS/

1.

Burner orifice is clogged

1.

Clean burner (see Cleaning

 

 

Pilot is lit

 

 

 

and Maintenance) or replace

 

 

 

 

 

 

burner orifice

 

 

 

2.

Inlet gas pressure is too low

2.

Contact local propane gas

 

 

 

 

 

 

company

 

 

 

 

 

 

 

 

 

 

 

Delayed ignition of burner

1.

Manifold pressure is too low

1.

Contact local propane gas

 

 

 

 

 

 

company

 

 

 

2.

Burner orifice is clogged

2.

Clean burner (see Cleaning

 

 

 

 

 

 

and Maintenance) or replace

 

 

 

 

 

 

burner orifice

 

 

 

 

 

 

 

 

 

 

Burner backfiring during

1.

Burner orifice is clogged or

1.

Clean burner (see Cleaning

 

 

combustion

 

damaged

 

and Maintenance) or replace

 

 

 

 

 

 

burner orifice

 

 

 

2.

Burner damaged

2.

Replace burner

 

 

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

Slight smoke or odor during

1.

Residues from manufacturing

1.

Problem will stop after a few

 

 

initial operation

 

process

 

hours of operation

 

 

Heater produces a whistling

1.

Turning control knob to “HI”

1.

Turn control knob to “LOW”

 

 

noise when burner is lit

 

position when burner is cold

 

position and allow to warm

 

 

 

 

(if equipped with this type of

 

 

 

 

 

 

 

 

valve)

 

 

 

 

 

 

 

2.

Air in gas line

2.

Operate burner until air is

 

 

 

 

 

 

removed from line. Call

 

 

 

 

 

 

local propane company to

 

 

 

 

 

 

check gas line.

 

 

 

3.

Air passageways on heater

3.

Observe minimum

 

 

 

 

blocked

 

installation clearances

 

 

 

4.

Dirty or partially clogged

4.

Clean burner or replace

 

 

 

 

burner orifice

 

orifice

Page 39

Image 43
Contents Spruce Pine, NC MODELVENT-FREE Manufacturer NEW BUCK CORPORATION P.O. Box 8000 Highway 226 SouthPage TABLE OF CONTENTS Page SECTION I SAFETY INFORMATION WARNINGS 6. What To Do IF You Smell Gas Shut off gas supply 32. This appliance is intended for supplemental heating FIREPLACE PREPARATION SECTIONGAS CONNECTION INSTALLATION AND CLEARANCESFLAME Page “MILLIVOLT ONLY” GAS PRESSURE CHECK LIGHTING INSTRUCTION MODULATING OR MANUAL VALVE SIT FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTION 13. Turn on all electrical power to the appliance 12. Close access panel doorto “ON” position. Continue to turn the to your desired setting THERMOSTAT CONTROL OPERATION MANUAL LIGHTING PROCEDURELIGHTING INSTRUCTIONS SIT-MILLIVOLT VALVE FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING INSTRUCTIONS Page Page MANUAL LIGHTING PROCEDURE FLAME CHECK WHEN USED AS A HEATING APPLIANCE HEAT OUTPUTCR 3329 LOG SET WIRING DIAGRAM NOTE #PE SBR084 Blower Motor Rating 120 volts/60HZ/1.1 Amps Trim Kit SECTION INSTALLATION MODEL 384 FP IN SOLID FUEL BURNING FIREPLACESCEILING Also provide adequate clearances around air openings OPTIONAL WOODEN SURROUND KIT#PAKDM384 SECTION INSTALLATION OF MODEL 384 WS WITHSTEP 7 Remove cloth or blanket from underneath stove DRAFTS SECTION ZERO CLEARANCE INSTALLATION OF MODEL 384 ZCCHOOSING THE LOCATION FOR YOUR FIREPLACE GAS LINE12.50” Front Of Top Trim Panel ZERO CLEARANCE STANDOFFS ASSEMBLY“Follow the instructions given in the diagrams below exactly” Top Standoff 2 per unitFraming the Firebox INSTALLING THE FIREBOXFIREPLACE CLEARANCES Install the FireboxCLEARANCES FINISHING YOUR FIREPLACESECTION MODEL 384 FS FREESTANDING INSTALLATION FREESTANDING PEDESTAL OR LEGS INSTALLATION CAUTION READ ENTIRE MANUAL BEFORE INSTALLING HEATER SECTION MODEL ALCOVE INSTALLATIONDETERMINING FRESH-AIR FLOW FOR HEATER LOCATION SECTION PRODUCING ADEQUATE VENTILATIONThis section is for residential or manufactured mobile installation 1. Determine the volume of the space length x width x height VENTILATION AIR FROM INSIDE BUILDING SECTION VENTILATION AIRVentilation Air From Outdoors VENTILATION AIR FROM OUTDOORSSECTION AFTER MARKET MOBILE HOME INSTALLATION CLEANING IMPORTANT SAFEGUARDSOBSERVED Air in gas lines when OBSERVED OBSERVED SERVICING REPAIR PARTSPART DESCRIPTION REPLACEMENT PARTSSIT MODULATING OR MANUAL VALVE KEY#PILOT 1719SIT MILLIVOLT VALVE REPLACEMENT PARTSSIT MILLIVOLT REPLACEMENT PARTS FOR EMBER STOVE BASE ESB 10 one is not available, you may contact SIT MILLIVOLTPage NEW BUCK CORPORATION LIMITED WARRANTY VENT-FREE GAS LOG HEATERPage