New Buck Corporation 32 manual Air in gas lines when

Page 33

 

4.

Air in gas lines when

4.

Continue to hold down control

 

 

installed

 

knob. Repeat igniting

 

 

 

 

operation until air is removed.

 

5.

Depleted gas supply

5.

Contact local propane gas

 

 

 

 

company

 

6.

ODS/Pilot is clogged

6.

Clean ODS/Pilot or replace

 

 

 

 

ODS/Pilot assembly

 

7.

Gas regulator setting is not

7.

Replace gas regulator

 

 

correct

 

 

OBSERVED

POSSIBLE

 

 

PROBLEM

PROBLEM

SOLUTION

 

 

 

 

 

ODS/PILOT lights but flame

1.

Control knob is not fully

1.

Press control knob completely

goes out when control knob is

 

pressed in

 

 

released

2.

Control knob not pressed in

2.

After ODS/Pilot lights keep

 

 

long enough

 

control knob pressed 30

 

 

 

 

seconds.

 

3.

Safety interlock system has

3.

Wait 1 minute for safety

 

 

been triggered (if equipped)

 

interlock system to reset.

 

4.

Manual shutoff valve not

4.

Fully open manual shutoff

 

 

fully open

 

valve.

 

5.

Thermocouple connection

5.

Hand tighten until snug, then

 

 

loose at control valve.

 

tighten 1/4 turn

 

6.

Pilot flame not touching

6.

A) contact local propane gas

 

 

thermocouple, which allows

 

company

 

 

thermocouple to cool,

 

B) Clean ODS/Pilot (See

 

 

causing pilot flame to go

 

Cleaning and Maintenance),

 

 

out. This problem can be

 

or replace ODS/Pilot

 

 

caused by one or both of the

 

assembly

 

 

following:

 

 

 

 

A) low gas pressure

 

 

 

 

B) dirty or partially

 

 

 

 

clogged ODS/Pilot

 

 

 

7.

Control valve damaged

7.

Replace valve control

Page 31

Image 33
Contents FREESTANDING FIREPLACE OR WITH AN MODELOPTIONAL WOODEN SURROUND VENT-FREEPage TABLE OF CONTENTS Page SECTION SAFETY INFORMATION WARNINGS Do not try to light any appliance psi 3.5 kPa CEILING FigureWALL LEFT SIDE7.Place logs on the burner base as shown on page FREESTANDING INSTALLATION MODEL 32 FS WALLWALL ALCOVE INSTALLATION FOR YOUR SAFETYWALL WS ASSEMBLY INSTRUCTIONS INSTALLATION OF MODEL 32 WSWITH OPTIONAL WOODEN SURROUNDKIT#PA-KDM32 Installation” for minimum clearancesINSTALLATION IN RESIDENTIAL OR AFTER-MARKETMOBILE HOMESNOTE: See “Producing Adequate Ventilation” page DETERMINING FRESH-AIRFLOW FOR HEATER LOCATION PRODUCING ADEQUATE VENTILATIONVent-freeheater VENTILATION AIR FROM INSIDE BUILDING VENTILATION AIRVENTILATION AIR FROM OUTDOORS TOP RIGHT PREPARING LOG KITTOP LEFT REAR LOG FRONT LOGFLAME GAS CONNECTIONGAS PRESSURE CHECK FOR YOUR SAFETY, READ BEFORE LIGHTING LIGHTING INSTRUCTIONS MILLIVOLT VALVE ITTWHAT TO DO IF YOU SMELL GAS LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE IGNITOR ELECTRODEPILOT BURNER THERMOSTAT CONTROL OPERATION MANUAL LIGHTING PROCEDUREFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTION MODULATING VALVE SITOR MANUAL VALVE SIT LIGHTING INSTRUCTION 12.Close access panel door 13.Turn on all electrical power to the appliancePage MANUAL LIGHTING PROCEDURE THERMOSTAT CONTROL OPERATION15seconds FLAME FLAME CHECKWIRING DIAGRAM CLEANING IMPORTANT SAFEGUARDSTROUBLE SHOOTING Air in gas lines when OBSERVED OBSERVED SERVICING REPAIR PARTSKEY# REPLACEMENT PARTSPART DESCRIPTION PART NUMBERITTGENERAL CONTROLS KEY# REPLACEMENT PARTSPART DESCRIPTION PART NUMBER5 6 13 PagePILOT NEW BUCK CORPORATION LIMITED WARRANTY MODEL FP-32Page