CEILING

MASONRY INSERT INSTALLATION/ SOLID FUEL BURNING FIREPLACE MODEL 32 (FP)

1.The Model 32 (FP) may be installed in a masonry fireplace.

Minimum fireplace dimensions: 25 1/2" high, 21-1/2" wide, 13" deep.

 

 

CEILING

 

 

 

 

42”

WALL

 

 

24"

 

 

16”

 

 

 

LEFT SIDE

 

 

RIGHT SIDE

 

7"

 

 

 

 

 

5”

 

 

 

 

13"

 

 

 

21-1/2"

25-1/2"

 

 

12"

 

 

FRONT

 

 

 

24” TO COMBUSTIBLES

Figure 1

 

WARNING: Before installing in a solid-fuel burning fireplace, the chim- ney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.”

NOTE: Any outside air ducts and / or ash dumps in the fireplace shall be per- manently closed at time of appliance installation.

“WARNING: Any glass doors shall be fully opened when appliance is in opera- tion.”

Your new Buck Vent-Free gas heater may be installed in a Residential or *After-Market Mobile Home, where prohibited by state or local codes.

*After-Market: Completion of sale. Not for purpose of resale from the manufacturer. This appliance is for use with the type of gas indicated on the rating plate. Not convertible for use with other gases.

2.Minimum dimensions sidewall and mantel: Sidewall-not less than 5" See Figure 1. Mantel-not less than 16" See Figure 1.

3.Center Model 32 in masonry fireplace. Position front of heater even with front of fireplace chamber if possible.

4.Place side trim panels flat against the fireplace. Draw a vertical reference line along the inside edge of the trim panel.

5.Place top trim panel on top of unit. Draw reference line for mounting on lower edge of pane NOTE: The installer of this appliance must mechanically (peel and stick) attach the marking supplied with this unvented appliance before installing to the inside of the firebox of the solid- fuel burning fireplace or listed ventless firebox enclosure into which the unvented fireplace in- sert is installed. See the example of the marking on page 18 of this manual.

CAUTION: Cutting any sheet-metal parts of the solid-fuel burning fireplace or listed ventless enclosure in which the unvented fireplace is to be installed is prohibited.

NOTE: “If the factory-built fireplace has no gas access hole(s) provided, an access hole of 1.5 inch (37.5) diameter or less may be drilled through the lower sides or bottom of the firebox in a proper workmanlike manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed.”

“Refractory, glass doors, screen rails, screen mesh and solid-fuel log grates (if applicable) can be removed from the fireplace before installing the unvented fireplace insert.”

“Smoke shelves shields and baffles may be removed if attached by mechanical fasteners.”

Page 6

Image 8
Contents MODEL FREESTANDING FIREPLACE OR WITH ANOPTIONAL WOODEN SURROUND VENT-FREEPage TABLE OF CONTENTS Page SECTION SAFETY INFORMATION WARNINGS Do not try to light any appliance psi 3.5 kPa Figure CEILINGWALL LEFT SIDE7.Place logs on the burner base as shown on page WALL FREESTANDING INSTALLATION MODEL 32 FSWALL WALL ALCOVE INSTALLATIONFOR YOUR SAFETY INSTALLATION OF MODEL 32 WS WS ASSEMBLY INSTRUCTIONSWITH OPTIONAL WOODEN SURROUNDKIT#PA-KDM32 Installation” for minimum clearancesNOTE: See “Producing Adequate Ventilation” page INSTALLATION IN RESIDENTIALOR AFTER-MARKETMOBILE HOMES PRODUCING ADEQUATE VENTILATION DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONVent-freeheater VENTILATION AIR VENTILATION AIR FROM INSIDE BUILDINGVENTILATION AIR FROM OUTDOORS PREPARING LOG KIT TOP RIGHTTOP LEFT REAR LOG FRONT LOGGAS CONNECTION FLAMEGAS PRESSURE CHECK WHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY, READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS MILLIVOLT VALVE ITT LIGHTING INSTRUCTIONS PILOT BURNER TO TURN OFF GAS TO APPLIANCEIGNITOR ELECTRODE MANUAL LIGHTING PROCEDURE THERMOSTAT CONTROL OPERATIONOR MANUAL VALVE SIT FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTION MODULATING VALVE SIT LIGHTING INSTRUCTION Page 12.Close access panel door13.Turn on all electrical power to the appliance 15seconds MANUAL LIGHTING PROCEDURETHERMOSTAT CONTROL OPERATION FLAME CHECK FLAMEWIRING DIAGRAM IMPORTANT SAFEGUARDS CLEANINGTROUBLE SHOOTING Air in gas lines when OBSERVED OBSERVED REPAIR PARTS SERVICINGREPLACEMENT PARTS KEY#PART DESCRIPTION PART NUMBERITTGENERAL CONTROLS REPLACEMENT PARTS KEY#PART DESCRIPTION PART NUMBERPILOT 5 6 13Page LIMITED WARRANTY MODEL FP-32 NEW BUCK CORPORATIONPage