Bryant operation manual Fan Performance 581A300 Low Heat Vertical Discharge Units

Page 22

Table 11 — Fan Performance — 581A300 Low Heat Vertical Discharge Units*

AIRFLOW

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

0.6

 

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

 

Bhp

Rpm

Watts

Bhp

Rpm

 

Watts

Bhp

Rpm

Watts

Bhp

6,500

750

2,468

2.84

806

2,767

 

3.18

854

3,031

3.49

898

 

3,298

3.79

943

3,584

4.12

7,000

797

2,942

3.38

853

3,276

 

3.77

899

3,557

4.09

941

 

3,832

4.41

982

4,118

4.74

7,500

845

3,468

3.99

900

3,840

 

4.42

945

4,142

4.76

985

 

4,430

5.09

1024

4,721

5.43

8,000

892

4,045

4.65

948

4,462

 

5.13

991

4,789

5.51

1030

 

5,092

5.86

1067

5,391

6.20

8,500

939

4,677

5.38

995

5,141

 

5.91

1038

5,497

6.32

1076

 

5,818

6.69

1112

6,129

7.05

9,000

986

5,364

6.17

1042

5,882

 

6.76

1085

6,269

7.21

1122

 

6,611

7.60

1157

6,936

7.98

9,500

1033

6,108

7.03

1090

6,684

 

7.69

1132

7,105

8.17

1169

 

7,470

8.59

1203

7,813

8.99

10,000

1079

6,911

7.95

1137

7,550

 

8.68

1180

8,007

9.21

1216

 

8,399

9.66

1249

8,761

10.08

10,500

1126

7,773

8.94

1184

8,480

 

9.75

1227

8,978

10.33

1263

 

9,399

10.81

1296

9,782

11.25

11,000

1172

8,696

10.00

1232

9,475

 

10.90

1274

10,017

11.52

1310

 

10,468

12.04

1342

10,876

12.51

11,500

1219

9,681

11.13

1279

10,539

 

12.12

1322

11,127

12.80

1357

 

11,611

13.35

12,000

1265

10,732

12.34

1326

11,669

 

13.42

 

12,500

1311

11,848

13.63

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

 

1.6

 

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

 

Bhp

Rpm

Watts

Bhp

Rpm

 

Watts

Bhp

Rpm

Watts

Bhp

6,500

988

3,900

4.49

1035

4,250

 

4.89

1082

4,634

5.33

1130

 

5,053

5.81

1177

5,499

6.32

7,000

1024

4,426

5.09

1066

4,760

 

5.48

1109

5,126

5.90

1153

 

5,524

6.35

1197

5,953

6.85

7,500

1063

5,026

5.78

1101

5,351

 

6.15

1141

5,702

6.56

1181

 

6,081

6.99

1222

6,490

7.46

8,000

1104

5,698

6.55

1140

6,020

 

6.92

1176

6,361

7.32

1213

 

6,727

7.74

1251

7,118

8.19

8,500

1146

6,443

7.41

1180

6,765

 

7.78

1214

7,103

8.17

1249

 

7,459

8.58

1283

7,837

9.01

9,000

1190

7,259

8.35

1222

7,586

 

8.73

1255

7,925

9.11

1287

 

8,276

9.52

1319

8,645

9.94

9,500

1235

8,148

9.37

1266

8,483

 

9.76

1296

8,824

10.15

1327

 

9,176

10.55

1357

9,541

10.97

10,000

1280

9,111

10.48

1310

9,456

 

10.88

1340

9,804

11.28

1369

 

10,158

11.68

1398

10,522

12.10

10,500

1326

10,147

11.67

1355

10,505

 

12.08

1384

10,862

12.49

 

11,000

1372

11,259

12.95

 

 

11,500

 

 

12,000

 

 

12,500

 

 

 

 

LEGEND

Bhp

Brake Horsepower Input to Fan

Watts

Input Watts to Motor

*Motor drive ranges: Low Range: 941-1176 High Range: 1014-1297

All other rpms require field-supplied drive.

Refer to page 23 for general Fan Performance Data notes.

NOTE: Maximum continuous bhp is:

Low Range: 8.63

High Range: 11.50

Table 12 — Fan Performance — 581A300 Medium Heat Vertical Discharge Units*

AIRFLOW

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

 

0.6

 

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

 

Bhp

Rpm

Watts

Bhp

Rpm

 

Watts

Bhp

Rpm

Watts

Bhp

6,500

775

2,600

2.99

825

2,872

 

3.30

871

3,130

3.60

915

 

3,400

3.91

959

3,692

4.25

7,000

826

3,115

3.58

875

3,408

 

3.92

918

3,679

4.23

959

 

3,954

4.55

1000

4,245

4.88

7,500

878

3,690

4.24

925

4,006

 

4.61

966

4,292

4.94

1005

 

4,575

5.26

1043

4,868

5.60

8,000

929

4,326

4.98

975

4,667

 

5.37

1015

4,970

5.72

1052

 

5,265

6.06

1088

5,564

6.40

8,500

981

5,029

5.78

1026

5,395

 

6.20

1064

5,717

6.58

1100

 

6,025

6.93

1134

6,332

7.28

9,000

1033

5,799

6.67

1076

6,191

 

7.12

1114

6,533

7.51

1148

 

6,856

7.89

1181

7,173

8.25

9,500

1085

6,640

7.64

1128

7,058

 

8.12

1164

7,421

8.54

1198

 

7,761

8.93

1229

8,091

9.31

10,000

1137

7,553

8.69

1179

8,000

 

9.20

1214

8,385

9.64

1247

 

8,741

10.05

1278

9,086

10.45

10,500

1190

8,542

9.82

1230

9,016

 

10.37

1265

9,424

10.84

1297

 

9,799

11.27

1327

10,158

11.68

11,000

1242

9,609

11.05

1282

10,111

 

11.63

1316

10,542

12.12

1347

 

10,937

12.58

1376

11,311

13.01

11,500

1294

10,756

12.37

1333

11,287

 

12.98

1367

11,741

13.50

 

12,000

1347

11,985

13.78

 

 

12,500

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

 

1.6

 

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Watts

Bhp

Rpm

Watts

 

Bhp

Rpm

Watts

Bhp

Rpm

 

Watts

Bhp

Rpm

Watts

Bhp

6,500

1004

4,016

4.62

1050

4,374

 

5.03

1098

4,769

5.48

1145

 

5,195

5.97

1192

5646

6.49

7,000

1041

4,559

5.24

1083

4,902

 

5.64

1126

5,277

6.07

1170

 

5,685

6.54

1214

6122

7.04

7,500

1081

5,179

5.96

1120

5,512

 

6.34

1159

5,872

6.75

1199

 

6,261

7.20

1240

6680

7.68

8,000

1124

5,875

6.76

1160

6,203

 

7.13

1196

6,553

7.54

1233

 

6,928

7.97

1270

7329

8.43

8,500

1168

6,647

7.64

1202

6,974

 

8.02

1235

7,318

8.42

1269

 

7,684

8.84

1304

8071

9.28

9,000

1214

7,495

8.62

1245

7,825

 

9.00

1277

8,168

9.39

1309

 

8,527

9.81

1341

8905

10.24

9,500

1260

8,421

9.69

1290

8,756

 

10.07

1320

9,100

10.47

1351

 

9,457

10.88

1381

9830

11.31

10,000

1308

9,425

10.84

1337

9,768

 

11.23

1365

10,116

11.63

1394

 

10,474

12.05

10,500

1356

10,510

12.09

1384

10,862

 

12.49

 

11,000

 

 

11,500

 

 

12,000

 

 

12,500

 

 

 

 

LEGEND

Bhp

Brake Horsepower Input to Fan

Watts

Input Watts to Motor

*Motor drive ranges: Low Range: 941-1176 High Range: 1014-1297

All other rpms require field-supplied drive.

Refer to page 23 for general Fan Performance Data notes.

NOTE: Maximum continuous bhp is:

Low Range: 8.63

High Range: 11.50

22

Image 22
Contents Safety Considerations ContentsInstallation Provide Unit Support II. Remove Shipping Rails III. RIG and Place UnitRoof Curb Details Shipping Rail Removal Base Unit Dimensions Physical Data CompressorFan Motor and Drive Data Vertical Supply/Return Fan Motor and Drive Data Horizontal Supply/Return Make Unit Duct Connections Vertical ConfigurationIV. Field Fabricate Ductwork Horizontal ApplicationsVIII. Install GAS Piping VI. Install Flue Hood and Inlet HoodVII. Trap Condensate Drain Field Control Wiring Field Power SupplyIX. Make Electrical Connections Install OUTDOOR-AIR Hood Manual Damper AssemblyElectrical Data Units Without Convenience Outlet FLA MCA MocpElectrical Data Units With Optional Convenience Outlet Outdoor-Air Hood Details XIII. Install ALL Accessories XII. NON-FUSED DisconnectPRE-START-UP III. Refrigerant Service PortsVI. Internal Wiring START-UPOUTDOOR-AIR Inlet Screens VIII. Condenser Fans and MotorsIX. RETURN-AIR Filters XI. GAS HeatFan Performance 581A210 Medium Heat Vertical Discharge Units Fan Performance 581A210 High Heat Vertical Discharge Units Fan Performance 581A240 Low Heat Vertical Discharge UnitsFan Performance 581A240 Medium Heat Vertical Discharge Units Fan Performance 581A240 High Heat Vertical Discharge UnitsFan Performance 581A300 Low Heat Vertical Discharge Units Fan Performance 581A300 Medium Heat Vertical Discharge UnitsFan Performance 581A300 High Heat Vertical Discharge Units General Notes for TablesFan Performance 581A210 Low Heat Horizontal Discharge Units Fan Performance 581A210 High Heat Horizontal Discharge Units Fan Performance 581A240 Low Heat Horizontal Discharge UnitsFan Performance 581A240 High Heat Horizontal Discharge Units Fan Performance 581A300 Low Heat Horizontal Discharge Units Power Exhaust Fan Performance Fan Performance 581A300 High Heat Horizontal Discharge UnitsEvaporator Fan Motor Specifications Operation Air Quantity LimitsEconoMi$er IV Controller Wiring and Operational Modes Accessory/FIOP Static Pressure in. wgFan Rpm at Motor Pulley Settings XII. Optional ECONOMI$ERSupply-Air Temperature Sensor Location EconoMi$er IV Component Locations Exploded ViewEconoMi$er IV Wiring Enthalpy Changeover Set Points Page XII. Operating Sequence CO2 Sensor Standard SettingsCooling, Units Without Economizer Heating, Units Without Economizer Service CleaningCoil Maintenance and Cleaning Recommendation Cooling, Units With EconoMi$erOutdoor-Air Inlet Screens Condensate DrainFilters Main BurnerIII. Evaporator FAN Service and Replacement II. LubricationBelt Tension Adjustment IV. Evaporator FAN Performance AdjustmentBelt Tension Adjustment VI. CONDENSER-FAN Adjustment FigIX. GAS Valve Adjustment VII. Power FailureVIII. Refrigerant Charge XI. Filter Drier Main BurnersXII. Protective Devices XIII. Relief Devices XV. Replacement PartsXIV. Control Circuit Low Voltage Control Schematic Low Voltage Control Schematic Power Schematic Component Arrangement Troubleshooting Unit Troubleshooting Cooling Service AnalysisHeating Service Analysis Problem Cause RemedyIGC Control Heating and Cooling II. ECONOMI$ER IV Troubleshooting EconoMi$er IV Troubleshooting Completion EconoMi$er IV Input/Output LogicCopyright 2005 Bryant Heating & Cooling Systems Catalog no Page Page Page Electrical START-UP ChecklistTemperatures Pressures
Related manuals
Manual 40 pages 46.88 Kb

581A specifications

The Bryant 581A is a pivotal model in the realm of heating, ventilation, and air conditioning (HVAC) systems, known for its robust performance and energy efficiency. As part of the Bryant product lineup, the 581A offers a blend of innovative technologies combined with reliable engineering, making it a suitable choice for both residential and light commercial applications.

One of the standout features of the Bryant 581A is its outstanding energy efficiency. With a Seasonal Energy Efficiency Ratio (SEER) rating of up to 16, this model meets Energy Star qualifications, ensuring that homeowners can enjoy lower utility bills while helping to reduce their environmental footprint. The efficiency is further enhanced by the unit’s environmentally friendly refrigerant, which not only improves performance but also aligns with modern sustainability standards.

Another key characteristic of the Bryant 581A is its durable construction. Designed to withstand various weather conditions, the unit features a robust cabinet that protects internal components. This durability not only prolongs the lifespan of the system but also minimizes the need for frequent maintenance or repairs. The coil design is optimized for heat transfer efficiency, enhancing the unit's overall performance in both cooling and heating modes.

In terms of technology, the Bryant 581A incorporates advanced control systems that enable precise temperature regulation. The multi-stage cooling capabilities ensure that the system can adapt to varying temperature demands, providing comfort in all seasons. Additionally, the model is compatible with smart thermostats, allowing homeowners to control their HVAC system remotely via smartphone or other connected devices.

Noise reduction is another aspect where the Bryant 581A excels. Equipped with a variable-speed compressor and sound-dampening features, this model operates quietly, minimizing disruption in residential or office environments. This focus on acoustic comfort makes it an ideal choice for those who value a peaceful living or working space.

Overall, the Bryant 581A represents an excellent balance of efficiency, durability, and modern technology. With features aimed at enhancing user comfort and reducing operational costs, it stands out as a reliable solution in the competitive HVAC market. Whether for new installations or replacements, the Bryant 581A is a testament to the brand’s commitment to quality and innovation in home climate control.