Table 30 — Fan Performance 580F150,151 — Horizontal Discharge Units; Alternate Motor (Belt Drive)*

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

0.2

 

 

0.4

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

3700

676

1.19

1106

747

1.42

1328

811

1.66

1552

871

1.91

1779

927

2.15

2008

3800

690

1.27

1185

760

1.52

1414

823

1.76

1644

882

2.01

1876

938

2.26

2111

3900

705

1.36

1269

773

1.61

1503

835

1.86

1739

894

2.12

1977

948

2.38

2217

4000

719

1.45

1357

786

1.71

1597

848

1.97

1838

905

2.23

2082

959

2.50

2328

4100

734

1.55

1449

799

1.82

1695

860

2.08

1942

917

2.35

2192

970

2.62

2443

4200

748

1.66

1545

813

1.93

1797

872

2.20

2050

928

2.47

2305

981

2.75

2562

4300

763

1.76

1646

826

2.04

1903

885

2.32

2162

940

2.60

2423

992

2.88

2686

4400

778

1.88

1751

840

2.16

2014

898

2.44

2279

952

2.73

2546

1004

3.02

2814

4500

792

1.99

1860

853

2.28

2130

910

2.57

2401

964

2.87

2673

1015

3.16

2947

4600

807

2.12

1975

867

2.41

2250

923

2.71

2527

976

3.01

2805

1027

3.31

3085

4700

822

2.25

2094

881

2.55

2375

936

2.85

2658

989

3.15

2942

1038

3.46

3227

4800

837

2.38

2218

895

2.69

2505

949

3.00

2794

1001

3.31

3083

1050

3.62

3375

4900

852

2.52

2347

909

2.83

2640

963

3.15

2935

1014

3.46

3230

1062

3.78

3528

5000

867

2.66

2482

923

2.98

2781

976

3.30

3081

1026

3.63

3383

1074

3.95

3685

5100

882

2.81

2622

937

3.14

2926

989

3.47

3232

1039

3.80

3540

1086

4.13

3849

5200

897

2.97

2766

951

3.30

3077

1003

3.63

3389

1052

3.97

3702

1099

4.31

4017

5300

912

3.13

2917

966

3.47

3233

1016

3.81

3551

1065

4.15

3870

1111

4.49

4191

5400

927

3.30

3073

980

3.64

3395

1030

3.99

3719

1078

4.34

4044

1123

4.69

4370

5500

943

3.47

3234

994

3.82

3563

1044

4.17

3892

1091

4.53

4223

1136

4.88

4555

5600

958

3.65

3402

1009

4.01

3736

1057

4.37

4071

1104

4.73

4408

1149

5.09

4746

5700

973

3.83

3575

1023

4.20

3915

1071

4.56

4256

1117

4.93

4599

5800

988

4.03

3754

1038

4.40

4100

1085

4.77

4447

1130

5.14

4796

5900

1004

4.22

3939

1052

4.60

4292

1099

4.98

4645

6000

1019

4.43

4131

1067

4.81

4489

1113

5.20

4848

6100

1034

4.64

4329

1082

5.03

4693

6200

1050

4.86

4533

6300

1065

5.09

4744

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

1.2

 

 

1.4

 

 

1.6

 

 

1.8

 

 

2.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

3700

981

2.40

2240

1031

2.65

2473

1079

2.91

2709

1125

3.16

2948

1169

3.42

3189

3800

990

2.52

2348

1040

2.77

2587

1088

3.03

2828

1133

3.30

3073

1177

3.56

3319

3900

1000

2.64

2459

1050

2.90

2705

1097

3.17

2951

1142

3.43

3201

1186

3.70

3452

4000

1011

2.76

2576

1059

3.03

2826

1106

3.30

3079

1151

3.58

3334

1194

3.85

3591

4100

1021

2.89

2697

1069

3.17

2953

1116

3.44

3210

1160

3.72

3471

1203

4.00

3733

4200

1031

3.03

2822

1079

3.31

3083

1125

3.59

3347

1169

3.87

3612

1212

4.16

3880

4300

1042

3.16

2951

1089

3.45

3218

1135

3.74

3487

1179

4.03

3758

1221

4.32

4031

4400

1053

3.31

3085

1100

3.60

3357

1145

3.90

3632

1188

4.19

3909

1230

4.49

4187

4500

1064

3.46

3224

1110

3.76

3502

1155

4.06

3782

1198

4.36

4064

1239

4.66

4348

4600

1075

3.61

3367

1121

3.91

3650

1165

4.22

3937

1208

4.53

4224

1249

4.84

4514

4700

1086

3.77

3515

1131

4.08

3805

1175

4.39

4096

1217

4.71

4389

1258

5.02

4684

4800

1097

3.93

3668

1142

4.25

3963

1186

4.57

4260

1228

4.89

4559

1268

5.21

4860

4900

1109

4.10

3826

1153

4.43

4128

1196

4.75

4430

1238

5.08

4734

5000

1120

4.28

3990

1164

4.61

4296

1207

4.94

4604

5100

1132

4.46

4159

1175

4.79

4471

1218

5.13

4784

5200

1144

4.65

4333

1187

4.99

4651

5300

1155

4.84

4512

1198

5.19

4836

5400

1167

5.04

4697

5500

1179

5.24

4889

5600

5700

5800

5900

6000

6100

6200

6300

LEGEND

Bhp — Brake Horsepower Input to Fan

Watts — Input Watts to Motor

*Motor drive range: 830 to 1130 rpm. All other rpms require field- supplied drive.

NOTES:

1.Boldface indicates field-supplied drive is required.

2.Maximum continuous bhp is 5.25.

3.See page 29 for General Fan Performance Notes.

49

Image 49
Contents Contents Important Read Before InstallingSafety Considerations InstallationBase Unit Dimensions 580F090,102,120,150 Base Unit Dimensions 580F091,103,121,151 Alternate Unit Support III. Install External Trap for CONDEN- Sate DrainSlab Mount Horizontal Units Only II. Field Fabricate DuctworkCRBTMPWR003A01 CRBTMPWR002A01CRBTMPWR004A01 CRRFCURB003A01Unit Leveling Tolerances Operating Dimensions Unit Weight Physical Data 580F090, 102, 120, 150 Units LOW Furnace SectionMED High091 103 121 151 Nominal Capacity tons 091 103 121 151 VI. Install GAS Piping Install Flue HoodField Power Supply Field Control WiringElectrical Data Without Convenience Outlet Heat Anticipator SettingsUnbalanced 3-Phase Supply Voltage Power Exhaust Electrical Data MCA MocpVoltage Type Electrical Data With Convenience OutletRLA LRA FLA FAN Motor MCA Mocp LRANEC IFCManual Outdoor-Air Damper VIII. Adjust FACTORY-INSTALLED OptionsWith Hood Attached ScrewsHood BOX Optional EconoMi$er+Bracket IAQ OATORH IarhDamper Movement EconoMi$er+ Controller WiringThermostats Outdoor Air Temperature OAT Sensor Provided EconoMi$er+ Field-Installed AccessoriesSupply Air Temperature SAT Sensor Provided Return Air Temperature RAT SensorIndoor Air Humidity Sensor Outdoor Air Humidity SensorVertical ECONOMI$ER+ 3 to 12 1/2 TON Units Temperature Resistance Low High Range ResolutionRemote EconoMi$er+ Enable Control Power ExhaustRemote Potentiometer Occupied Minimum Position Demand Ventilation Control CO2 Sensor ConfigurationIX. Adjust EVAPORATOR-FAN Speed CO2 Sensor* Standard SettingsUnit Motor Efficiency Evaporator-Fan Motor EfficiencyGeneral Notes for FAN Performance Data Tables Evaporator-Fan Motor PerformanceUnit EVAPORATOR-FAN Maximum Acceptable Continuous BHP2300 521 531 2250 513 5052400 535 584 2500 551 642741 671 972 713 665 940802 684 8661222 791 1489 2400 535 584 1187 786 1453 2300 521 5311293 802 1566 2500 551 642 866 6963900 38004000 4100 4200 42502156 3800 761 18423900 777 1974 2296978 1447 3200 962 1373 3100942 1323 993 1524 3300 958 1400 1008 1604 34003100 746 713 811 883 3000 726 656 793 8223200 766 773 829 947 3300 786 836Airflow 3800 744 1361 804 1572 3700 728 1266 789 1473 8483900 760 1460 819 1676 4000 777 1563 834 17854000 777 1563 3700 728 1266 789 14734100 793 1672 1139 4208 5200681 2250 505 4842300 513 509 2400 527 561708 663 931 681 657 901766 674 993 8941174 787 1437 2400 527 561 1142 782 1403 2300 513 5091241 796 1508 2500 543 617 828 6864200 4250 2074 3800 753 17833900 770 1912 2209765 3000 555 6303100 568 686 8251048 814 1198 3100 568 686 765 696 904825 706 968 1115 823 1269 3200 582 745955 728 1106 888 717 10351026 739 1181 1100 750 12591328 811 3700 676 11063800 690 1185 1414 8233800 690 1185 760 1414 823 3700 676 1106 747 1328 8113900 705 1269 773 1503 4000 719 1357 786 1597VII. Refrigerant Service Ports Internal WiringPRE-START-UP START-UP Unit PreparationXI. Main Burners CoolingXII. Heating XIII. Integrated GAS Controller IGC Operation XIV. Safety ReliefXVI. ECONOMI$ER+ Controller DS1 DS2 DS3 DS4 EconoMi$er+ Controller BoardEconoMi$er+ Inputs and Outputs Start-Up Mode SequenceSetup Points Units Minimum Maximum Factory INC Comments Configuration Variables Read and Setup ModesValue Setting Input/Output ChannelsSetup Mode Error Mode Manual ModeCompressor Configuration And Control XVII. ECONOMI$ER+ ConfigurationVentilation Air And Free Cooling Power Exhaust Configuration Demand Ventilation ConfigurationCooling, Units Without EconoMi$er+ XVIII. Operating SequenceHeating, Units Without EconoMi$er+ Cooling, Units With EconoMi$er+Service Cleaning VI. Economizer Adjustment IV. Blower Belt AdjustmentVIII. HIGH-PRESSURE Switch IX. LOSS-OF-CHARGE SwitchCooling Charging Chart 580F090 To Use Cooling Charging ChartCooling Charging Chart 580F120 Cooling Charging Chart 580F091 Cooling Charging Chart 580F121 XII. Flue GAS Passageways XIV. Limit SwitchXIII. COMBUSTION-AIR Blower XV. Burner IgnitionXVII. Replacement Parts Cleaning and AdjustmentTroubleshooting ECONOMI$ER+ Troubleshooting II. Unit Troubleshooting Problem Cause Remedy Cooling Service TroubleshootingHeating Service Troubleshooting Typical Unit Wiring Schematic 208/230-3-60 Unit Shown Appendix a ECONOMI$ER+ Label Startup ModeAppendix a ECONOMI$ER+ Label Appendix B JOB Specific ECONOMI$ER+ Configuraiton Settings Index Call for Free Catalog Service TrainingPage Remove and Store in Job File START-UP ChecklistPreliminary Information III. START-UP Electrical
Related manuals
Manual 64 pages 4.35 Kb Manual 52 pages 44.41 Kb

580F specifications

The Bryant 580F is a highly regarded gas furnace known for its exceptional heating performance and advanced technology. Designed for residential use, this model stands out for its reliability, efficiency, and user-friendly features that cater to modern heating demands.

One of the most notable features of the Bryant 580F is its efficiency rating. With an AFUE (Annual Fuel Utilization Efficiency) rating of up to 95%, this furnace maximizes heat output while minimizing energy consumption. This high level of efficiency not only results in lower utility bills but also reduces the environmental impact—a critical consideration for today’s eco-conscious homeowners.

The Bryant 580F is equipped with a multi-speed blower that ensures consistent airflow and enhances comfort by maintaining even temperatures throughout the home. This technology allows the furnace to adjust its operation based on the heating needs, leading to quieter operation and increased comfort levels.

In terms of construction, the Bryant 580F is built with durable materials that promise longevity and resilience against wear and tear. Its compact design makes installation easier, allowing it to fit into tight spaces without compromising its performance.

One of the standout technologies integrated into the Bryant 580F is its enhanced control system. The furnace works seamlessly with smart thermostats, allowing homeowners to monitor and adjust heating settings from their mobile devices. This feature not only provides convenience but also allows for energy-saving optimizations based on personal schedules and preferences.

Safety is also a primary concern with the Bryant 580F. It includes robust safety features such as a hot surface ignition system that eliminates the need for a standing pilot light, reducing the risk of gas leaks. Additionally, advanced diagnostics help in troubleshooting and maintenance, ensuring that potential issues can be identified and resolved quickly.

In conclusion, the Bryant 580F gas furnace is a remarkable choice for those seeking a blend of efficiency, comfort, and advanced technology. Its high AFUE rating, multi-speed blower, smart control compatibility, and safety features make it a reliable option for homeowners looking to invest in a dependable heating solution. As the demand for energy-efficient heating continues to grow, the Bryant 580F stands out as a model that meets and exceeds expectations in the modern heating landscape.