Table 23 — Power Exhaust Fan Performance — 48PG20-28

AIRFLOW

 

 

 

LOW SPEED

 

 

 

 

MEDIUM SPEED

 

 

 

 

 

HIGH SPEED

 

 

(Cfm)

 

208

V

 

230,460,575V

 

208 V

 

230,460,575V

 

208

V

 

230,460,575V

 

ESP

Bhp

Watts

ESP

Bhp

Watts

ESP

Bhp

Watts

ESP

 

Bhp

Watts

ESP

Bhp

Watts

ESP

Bhp

Watts

3250

0.32

1.41

1580

0.70

1.49

1670

 

3350

0.23

1.44

1610

0.63

1.52

1700

0.60

1.51

1690

0.82

 

1.62

1810

 

3450

0.17

1.46

1635

0.59

1.55

1730

0.55

1.54

1720

0.78

 

1.64

1840

 

3550

0.13

1.47

1645

0.56

1.56

1745

0.49

1.56

1750

0.73

 

1.67

1870

 

3650

0.09

1.49

1665

0.53

1.58

1765

0.43

1.59

1780

0.68

 

1.70

1900

 

3750

 

0.51

1.60

1790

0.39

1.62

1815

0.64

 

1.72

1930

3850

 

0.48

1.62

1810

0.33

1.64

1835

0.59

 

1.74

1950

0.60

1.85

2070

0.73

1.99

2230

3950

 

0.45

1.64

1835

0.27

1.66

1860

0.54

 

1.76

1975

0.56

1.87

2095

0.69

2.01

2255

4050

 

0.40

1.67

1865

0.22

1.68

1885

0.49

 

1.79

2000

0.51

1.89

2120

0.65

2.04

2280

4250

 

0.17

1.74

1945

0.40

 

1.84

2060

0.41

1.92

2145

0.56

2.06

2310

4450

 

0.00

1.79

2005

0.30

 

1.89

2115

0.31

1.97

2205

0.47

2.12

2370

4650

 

0.22

 

1.94

2170

0.20

2.04

2280

0.37

2.19

2450

4850

 

0.16

 

1.98

2215

0.11

2.09

2335

0.30

2.24

2505

5050

 

0.12

 

2.02

2260

0.04

2.13

2385

0.23

2.28

2555

5250

 

 

 

0.17

2.33

2610

5450

 

 

 

0.12

2.38

2665

5650

 

 

 

0.07

2.40

2690

5850

 

 

 

0.04

2.42

2710

LEGEND

ESP — External Static Pressure

Table 24 — Operation Air Quantity Limits

 

 

 

 

HEATING

HEATING

HEATING

HEATING

48PG

COOLING

GAS HEAT

(NAT. GAS,

(NAT. GAS,

(PROPANE,

(PROPANE,

 

 

VERTICAL)

HORIZONTAL)

VERTICAL)

HORIZONTAL)

 

 

 

 

 

Minimum Cfm

Maximum Cfm

 

Minimum Cfm

Minimum Cfm

Minimum Cfm

Minimum Cfm

 

 

 

High Heat (8 Cell)

5522

5522

5522

4920

20

5000

9,000

Medium Heat (8 Cell)

4977

4977

4480

4480

 

 

 

Low Heat (5 Cell)

4218

4218

4218

3796

 

 

 

High Heat (8 Cell)

5522

5522

5522

4920

24

5500

10,000

Medium Heat (8 Cell)

4977

4977

4480

4480

 

 

 

Low Heat (5 Cell)

4218

4218

4218

3796

 

 

 

High Heat (8 Cell)

5522

5470*

5522

4920*

28

6500

12,000

Medium Heat (8 Cell)

4977

4977*

4480

4480*

 

 

 

Low Heat (5 Cell)

4218

4218

4218

3796

*7000 cfm minimum recommended above 1.0 in. wg external static pressure.

Table 25 — Evaporator Fan Motor Specifications

48PG

DRIVE

ORIENTATION

MOTOR P/N

NOMINAL HP

VOLTAGE

MAX WATTS

EFFICIENCY %

MAX BHP

MAX BkW

MAX AMPS

 

 

 

HD60FK651

3.7

208

3698

85.8

4.25

3.17

10.6

 

Low

Vertical

HD60FK651

3.7

230

3698

85.8

4.25

3.17

9.6

 

HD60FK651

3.7

460

3698

85.8

4.25

3.17

4.8

 

 

 

 

 

 

HD60FK575

5

575

4900

87.5

5.75

4.29

6.1

 

 

 

HD60FK653

5

208

4900

87.5

5.75

4.29

16.7

 

Mid-Low

Vertical

HD60FK653

5

230

4900

87.5

5.75

4.29

15.2

 

HD60FK653

5

460

4900

87.5

5.75

4.29

7.6

 

 

 

 

 

 

HD60FK575

5

575

4900

87.5

5.75

4.29

6.1

 

 

 

HD62FK652

7.5

208

7267

88.5

8.63

6.43

24.2

 

Mid-High

Vertical

HD62FK652

7.5

230

7267

88.5

8.63

6.43

22

 

HD62FK652

7.5

460

7267

88.5

8.63

6.43

11

 

 

 

 

 

 

HD62FK576

7.5

575

7267

88.5

8.63

6.43

9

 

 

 

HD64FK651

10

208

9582

89.5

11.5

8.58

30.8

 

High

Vertical

HD64FK651

10

230

9582

89.5

11.5

8.58

28

 

HD64FK651

10

460

9582

89.5

11.5

8.58

14

 

 

 

20

 

 

HD64FK575

10

575

9582

89.5

11.5

8.58

11

 

 

N/A

N/A

208

N/A

N/A

N/A

N/A

N/A

 

 

 

 

Low

Horizontal

N/A

N/A

230

N/A

N/A

N/A

N/A

N/A

 

N/A

N/A

460

N/A

N/A

N/A

N/A

N/A

 

 

 

 

 

 

N/A

N/A

575

N/A

N/A

N/A

N/A

N/A

 

 

 

HD60FK651

3.7

208

3698

85.8

4.25

3.17

10.6

 

Mid-Low

Horizontal

HD60FK651

3.7

230

3698

85.8

4.25

3.17

9.6

 

HD60FK651

3.7

460

3698

85.8

4.25

3.17

4.8

 

 

 

 

 

 

HD60FK575

5

575

4900

87.5

5.75

4.29

6.1

 

 

 

HD60FK653

5

208

4900

87.5

5.75

4.29

16.7

 

Mid-High

Horizontal

HD60FK653

5

230

4900

87.5

5.75

4.29

15.2

 

HD60FK653

5

460

4900

87.5

5.75

4.29

7.6

 

 

 

 

 

 

HD60FK575

5

575

4900

87.5

5.75

4.29

6.1

 

 

 

HD62FK652

7.5

208

7267

88.5

8.63

6.43

24.2

 

High

Horizontal

HD62FK652

7.5

230

7267

88.5

8.63

6.43

22

 

HD62FK652

7.5

460

7267

88.5

8.63

6.43

11

 

 

 

 

 

 

HD62FK576

7.5

575

7267

88.5

8.63

6.43

9

37

Image 37
Contents Installation, Start-Up and Service Instructions Provide Unit Support InstallationRoof Curb Details Shipping Rail Removal Base Unit Dimensions Compressor Physical DataFan Motor and Drive Data Vertical Supply/Return Fan Motor and Drive Data Horizontal Supply/Return Alignment Hole Details Make Unit Duct ConnectionsConcentric Duct Details Install Flue Hood and Inlet HoodCondensate Drain Details Make Electrical ConnectionsField Power Wiring Connections Supply Optional Hacr Size Supply Optional Hacr Size Voltage Breaker Outdoor-Air Hood Details Outdoor-Air Hood Assembled Power Exhaust or Barometric Relief Damper Mounting Details PRE-START-UP Fan Performance 48PGD20 Vertical Supply/Return Units Fan Performance 48PGE20 Vertical Supply/Return Units 8500 940 Fan Performance 48PGF20 Vertical Supply/Return UnitsFan Performance 48PGD24 Vertical Supply/Return Units Fan Performance 48PGE24 Vertical Supply/Return Units 500 940 Fan Performance 48PGF24 Vertical Supply/Return Units10,500 Fan Performance 48PGD28 Vertical Supply/Return Units11,000 1310 11.76 1342 12.33 11,5001327 11.47 11,000 Fan Performance 48PGE28 Vertical Supply/Return Units1304 000 1309 1341 10.09 500Fan Performance 48PGF28 Vertical Supply/Return Units Fan Performance 48PGD20 Horizontal Supply and Return Units Fan Performance 48PGE20 Horizontal Supply and Return Units Fan Performance 48PGF20 Horizontal Supply and Return Units Fan Performance 48PGD24 Horizontal Supply and Return Units Fan Performance 48PGE24 Horizontal Supply and Return Units 1354 1391 000 1381 500 10,000 Fan Performance 48PGF24 Horizontal Supply and Return Units1328 10.37 1358 10.87 10,000 Fan Performance 48PGD28 Horizontal Supply and Return Units1308 1340 10.08 500 Fan Performance 48PGE28 Horizontal Supply and Return UnitsGeneral Notes for FAN Performance Data Tables Fan Performance 48PGF28 Horizontal Supply and Return UnitsEvaporator Fan Motor Specifications Power Exhaust Fan Performance 48PG20-28Operation Air Quantity Limits Evaporator Fan Motor Specifications Fan Rpm at Motor Pulley Settings Accessory/FIOP Static Pressure in. wg* 48PG20-28EconoMi$er IV Sensor Usage EconoMi$er IV Wiring Enthalpy Changeover Set Points Page Operating Sequence CO2 Sensor Standard SettingsSubcooler Operation Service Removing Heat Exchanger Ceramic LubricationEvaporator-Fan Motor Adjustment Belt Tension Adjustment Condenser-Fan Adjustment FigSensor Temperature/Resistance Values Unit Model Number PositionCharging Chart 48PG20 Gas Valve AdjustmentGas Valve Altitude Compensation Protective DevicesTypical Low Voltage Control Schematic Typical Power Schematic Typical Component Arrangement 48PG20,24 Typical Component Arrangement 48PG28 Cooling Service Analysis TroubleshootingBurners Will Not Ignite Gas Heating Service AnalysisIGC Control Heating and Cooling IGC Board LED Alarm Codes EconoMi$er IV TroubleshootingFlash FlashesLED Status Function Copyright 2005 Carrier Corporation Page Unit START-UP Checklist