Carrier 48PG20-28 specifications Typical Component Arrangement 48PG28

Page 56

56

LEGEND FOR FIG. 42-45

THERMOSTAT/IGC MARKINGS BM — Blower Motor

CCommon CM — Inducer Motor

CS — Centrifugal Switch G — Fan

IFO — Indoor Fan On L1 — Line 1

R — Thermostat Power RT — Power Supply SS — Speed Sensor W — Thermostat Heat W1 — 1st Stage of Heating W2 — 2nd Stage of Heating X — Alarm Output

Y1 — 1st Stage of Cooling

Y2 — 2nd Stage of Cooling

 

---A

Circuit A

 

AUX

Auxiliary Contact

 

AL

Ambient Limit

 

---B

Circuit B

 

C

Compressor Contactor

 

CAP

Capacitor

 

CB

Compressor Circuit Breaker

 

CCH

Crankcase Heater

 

CLO

Compressor Lockout

 

COMP

Compressor

 

CT BRK —

Circuit Breaker

 

CR

Control Relay

 

DU

Dummy Terminal

 

ECB

Economizer Control Board

 

FCS

Fan Cycling Switch

 

FIOP

Factory-Installed Option

 

FPT

Freeze Protection Thermostat

 

FS

Flame Sensor

 

FU

Fuse

 

GND

Ground

 

GV

Gas Valve

 

HACR — Heating, Air Conditioning,

 

 

 

and Refrigeration

 

HERM

Hermetic

NOTES:

HPS

High-Pressure Switch

1. Factory wiring is in accordance with the National Electrical Codes. Any

I

Ignitor

field modifications or additions must be in compliance with all applicable

IAQ

Indoor Air Quality

codes.

IDM

Induced-Draft Motor

2. Use 75° C min wire for field power supply. Use copper wires for all units.

IDR

Induced Draft Relay

3. All circuit breakers “Must Trip Amps” are equal to or less than 156% RLA.

IFC

Indoor-Fan Contactor

4. Compressor and fan motors are thermally protected. Three-phase motors

IFCB

Indoor Fan Circuit Breaker

protected against primary single-phase conditions.

IFM

Indoor-Fan Motor

5. The CLO locks out the compressor to prevent short cycling on compressor

IGC

Integrated Gas Controller

overload and safety devices. Before replacing CLO, check these devices.

LOR

Lockout Relay

LPS

Low-Pressure Switch

LS

Limit Switch

OAS

Outdoor-Air Sensor

OFC

Outdoor-Fan Contactor

OFM

Outdoor-Fan Motor

PEC

Power Exhaust Contactor

PEM

Power Exhaust Motor

PL

Plug

PLP

Phase Loss Protection

QC

Quick Connect

QT

Quadruple Terminal

RAS

Return Air Sensor

RS

Rollout Switch

SAT

Supply-Air Temperature

TB

Terminal Block

TRAN

Transformer

TXV

Thermostatic Expansion Valve

W/AT

With Auxiliary Trip

 

Terminal Block

 

Terminal (Unmarked)

 

Terminal (Marked)

 

Factory Wiring

 

Field Wiring

 

To Indicate Common Potential

 

Only. Not to Represent Wiring.

 

To Indicate FIOP or Accessory

Fig. 45 — Typical Component Arrangement — 48PG28

Image 56
Contents Installation, Start-Up and Service Instructions Installation Provide Unit SupportRoof Curb Details Shipping Rail Removal Base Unit Dimensions Physical Data CompressorFan Motor and Drive Data Vertical Supply/Return Fan Motor and Drive Data Horizontal Supply/Return Make Unit Duct Connections Alignment Hole DetailsInstall Flue Hood and Inlet Hood Concentric Duct DetailsMake Electrical Connections Condensate Drain DetailsField Power Wiring Connections Supply Optional Hacr Size Supply Optional Hacr Size Voltage Breaker Outdoor-Air Hood Details Outdoor-Air Hood Assembled Power Exhaust or Barometric Relief Damper Mounting Details PRE-START-UP Fan Performance 48PGD20 Vertical Supply/Return Units Fan Performance 48PGE20 Vertical Supply/Return Units Fan Performance 48PGF20 Vertical Supply/Return Units 8500 940Fan Performance 48PGD24 Vertical Supply/Return Units Fan Performance 48PGE24 Vertical Supply/Return Units Fan Performance 48PGF24 Vertical Supply/Return Units 500 940Fan Performance 48PGD28 Vertical Supply/Return Units 10,50011,000 1310 11.76 1342 12.33 11,500Fan Performance 48PGE28 Vertical Supply/Return Units 1327 11.47 11,0001304 000 1309 1341 10.09 500Fan Performance 48PGF28 Vertical Supply/Return Units Fan Performance 48PGD20 Horizontal Supply and Return Units Fan Performance 48PGE20 Horizontal Supply and Return Units Fan Performance 48PGF20 Horizontal Supply and Return Units Fan Performance 48PGD24 Horizontal Supply and Return Units Fan Performance 48PGE24 Horizontal Supply and Return Units Fan Performance 48PGF24 Horizontal Supply and Return Units 1354 1391 000 1381 500 10,000Fan Performance 48PGD28 Horizontal Supply and Return Units 1328 10.37 1358 10.87 10,000Fan Performance 48PGE28 Horizontal Supply and Return Units 1308 1340 10.08 500Fan Performance 48PGF28 Horizontal Supply and Return Units General Notes for FAN Performance Data TablesOperation Air Quantity Limits Power Exhaust Fan Performance 48PG20-28Evaporator Fan Motor Specifications Evaporator Fan Motor Specifications Accessory/FIOP Static Pressure in. wg* 48PG20-28 Fan Rpm at Motor Pulley SettingsEconoMi$er IV Sensor Usage EconoMi$er IV Wiring Enthalpy Changeover Set Points Page CO2 Sensor Standard Settings Operating SequenceSubcooler Operation Service Lubrication Removing Heat Exchanger CeramicEvaporator-Fan Motor Adjustment Condenser-Fan Adjustment Fig Belt Tension AdjustmentSensor Temperature/Resistance Values Unit Model Number PositionGas Valve Adjustment Charging Chart 48PG20Gas Valve Protective Devices Altitude CompensationTypical Low Voltage Control Schematic Typical Power Schematic Typical Component Arrangement 48PG20,24 Typical Component Arrangement 48PG28 Troubleshooting Cooling Service AnalysisGas Heating Service Analysis Burners Will Not IgniteIGC Control Heating and Cooling EconoMi$er IV Troubleshooting IGC Board LED Alarm CodesFlash FlashesLED Status Function Copyright 2005 Carrier Corporation Page Unit START-UP Checklist